background image

EN

3

Parts Identification

Caution

Specifications

ON/OFF Button

C) Remote Controller Panel

Timer Button

Mode Button

Cool / Humidify Button

* Specifications are subject to change without prior notice.

Wind Speed Button

Swing Button

Model
Voltage
Power
Water Tank Capacity
Fan Speed
Air Delivery
Water Consumption 
Net Weight
Product Dimension (LxWxH)

EAC20
220-240V~ 50Hz
110W
20 Litres
480~1260rpm
9.17m /min ; 323CFM
2000mL/h
8kg
390 x 342 x 897mm

1.  Use this appliance with specified voltage as stated on the rating sticker. Before connecting to   

     AC mains, make sure the specified voltage corresponds to the AC supply to your house.

2.  This cooler must be operated only under the following conditions.

      - Room temperature : 18˚C to 45˚C

      - Water (refilling) temperature : <45˚C 

3. Do not operate the cooler in dirty, dusty or polluted environments.

4. Insert the plug to the AC mains securely. Do not remove power plug by pulling through its 

     cord. Do not operate with wet hands or when the plug is wet.

5. Do not fill water beyond maximum capacity of the water tank.

6. Do not operate the cooler with cool /humidify function if the water level is below the 

     minimum mark.

7. Do not operate the cooler in an enclosed environment. It will cause dampness and damage to 

     the paper materials.

8. This appliance is not intended for use by persons (including children) with reduced physical, 

     sensory or mental capabilities, or lack of experience and knowledge, unless they have been 

     given supervision or instruction concerning use of the appliance by a person responsible for 

     their safety. 

     Children should be supervised to ensure that they do not play with the appliance.

9.  If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or 

     similarly qualified persons in order to avoid a hazard.

3

Содержание EAC20

Страница 1: ...ortant Mustahak Please read this manual carefully before operating this product Keep this manual handy for further reference Sila baca buku panduan ini dengan teliti sebelum menggunakan produk ini Sim...

Страница 2: ...ckle Left Shell Remote Control Receiver Water Level Display Window Reel Picture is for illustration purpose only Top Panel Cover Rear Casters Right Shell Water Pump Rod Stopper Horizontal Louver Remot...

Страница 3: ...rty dusty or polluted environments 4 Insert the plug to the AC mains securely Do not remove power plug by pulling through its cord Do not operate with wet hands or when the plug is wet 5 Do not fill w...

Страница 4: ...flux 16 Do not install this appliance in locations containing inflammable or explosive gases and sprays Do not expose it directly to sunlight for a long period of time 17 Do not insert fingers wooden...

Страница 5: ...button and the unit will turn off and enter standby mode Press this button again and the unit will resume last wind speed If the wind speed before shutdown is low or silent it starts from the medium...

Страница 6: ...s T 90s T 90s stop stop Natural mode in medium speed Natural mode in low speed 2 Wind speed button The wind speed can be converted in the following sequence Silent low medium high silent and circulate...

Страница 7: ...ore packing the unit Press and hold Speed button on the panel for 3 seconds to turn on the air dry function When the air dry function is turned on the wind speed jumps from the current speed level to...

Страница 8: ...ider to the tank bottom Slide Water Pump Slider again to raise the pump rod to the top Loosen Water Tank Buckle on both sides A Water filling 1 You need to add water to the tank if the cool humidify f...

Страница 9: ...dry function to dry the unit and the honeycomb filter then pull out the plug Loosen the Water Tank Buckle slide the Water Pump Slider to move the pump rod to the top and insert the Water Pump Rod Sto...

Страница 10: ...CN 10 1 7 13 14 16 15 5 6 3 9 2 8 4 10 17 11 18 12 19 20 21 A B 1 13 14 15 16 2 3 4 5 6 7 8 9 10 17 18 19 20 11 12 21...

Страница 11: ...CN 11 C x x x x 1 2 18 C to 45 C 45 C 3 4 5 6 MIN 7 8 9 10 11 Khind Mistral M Sdn Bhd EAC20 220 240V 50Hz 110W 20 480 1260rpm 9 17m min 323CFM 2000 8 390 x 342 x 897 3...

Страница 12: ...CN 12 12 13 14 15 16 17 18 19 i ii iii 1 a b c 2 3 4...

Страница 13: ...CN 13 A 1 2 B 1 1 2 2 3 3 1 2...

Страница 14: ...CN 14 4 4 5 5 1 2 4 8 1 2 6 6 1 2 6 6 6 12 12 12 18 21 33 45 48 54 69 72 78 84 24 30 33 39 43 51 57 63 69 72 78 84 18 21 27 39 45 51 57 63 69 72 84 T 90 T 90 T 90 3 30 30 30 30...

Страница 15: ...CN 15 C 1 60 2 50 5 10 3 4 3 20 0 5 20 20 20 5 i 30 ii 30 ON 6 15 A A 1 1 2 1 2...

Страница 16: ...CN 16 5 2 3 4 3 5 i MAX ii iii 3 4...

Страница 17: ...CN 17 7 8 6 B B 6 7 C C 1 1 3V CR2032 2 CR2032 8...

Страница 18: ...angka Kiri Penerima Pancaran Alat Kawalan Jauh Tingkap Paparan Paras Air Gelendung Pelindung Panel Atas Roda Belakang Kerangka Kanan Penghalang Rod Pam Air Daun Tetingkap Melintang Alat Kawalan Jauh G...

Страница 19: ...Suhu bilik 18 C hingga 45 C Suhu air pengisian semula 45 C 3 Jangan operasikan perkakas ini di dalam keadaan persekitaran kotor atau tercemar 4 Masukkan plag AC dengan sebaiknya Jangan keluarkan plag...

Страница 20: ...a perkakas 15 Jangan sandarkan perkakas ini pada dinding atau langsir atau objek lain yang mungkin menghalang aliran udara 16 Jangan memasang perkakas ini di lokasi yang mengandungi gas gas mudah terb...

Страница 21: ...tidak menggunakan perkakas ini 4 Sekiranya perkakas tidak digunakan untuk tempoh yang lama tanggalkan tangki air buangkan air di dalamnya dan kemudian pasang semula dengan kemas Hidupkan fungsi udara...

Страница 22: ...kalkan 2 Butang kelajuan Angin kelajuan angin boleh diubah mengikut aturan kitaran seperti berikut Senyap rendah Pertengahan Tinggi Senyap secara berkitaran LED akan menyala untuk menunjuk kedudukan m...

Страница 23: ...ngsi Perlindungan Paras Air Apabila fungsi sejuk diaktifkan pam air akan berkerja selama 50 saat Jika dalam tempoh ini kekurangan air dikesan pam akan berhenti beroperasi dan penggera akan berbunyi se...

Страница 24: ...a akan berbunyi beep 10 kali selepas bekalan kuasa kembali pulih Selepas 30 saat unit akan kembali beroperasi mengikut tetapan sebelumnya ii Jika anda menekan butan ON semula dalam tempoh saat tersebu...

Страница 25: ...ras air terletak di sebelah hadapan perkakas Gambarajah 5 1 Jangan masukkan air melebihi paras maksimum 2 Pastikan air yang digunakan adalah bersih 3 Tip Jika terdapat sedikit bauan pada perkakas atau...

Страница 26: ...Penerima Pancaran yang terletak pada unit Jika voltan bateri berkurangan sila buka penutupnya seperti ditunjukkan pada gambarajah 8 dan gantikan dengan bateri CR2032 yang baru Pastikan polar positif d...

Страница 27: ......

Страница 28: ...www khind com my...

Отзывы: