Operating & Maintenance
AV & EV Booster Sets
5). Storage & Handling:
➢
The booster set is covered in a protective film (this is to remain in place until ready for
install).
➢
The product must be stored in a covered and dry location, free from dirt, heat and vibrations.
➢
The product must be stored at an ambient temperature between: 5
c to 40
c.
➢
Do not place heavy weights on packaged products as this may cause damage.
➢
If the equipment is to be stored for any length of time all liquids within the pumps should be
drained and the vent and bleed plugs removed and safely stored.
6). Operating Limits:
FLUID TEMPERATURE
5
C to 80
C
AMBIENT TEMPERATURE
5
C to 40
C
OPERATING PRESSURE
8 Bar, 10bar, 16Bar (dependent on model)
PROTECTION CLASS (MOTOR, PANEL, VSD)
IP55
STARTS PER HOUR
See below table 1.1
Table 1.1
Kw
0.25
– 3
4
– 7.5
11
– 15
18.5
– 22
30
– 37
45
55
Starts per
Hour
60
40
30
24
16
8
4
Noise emissions:
Assembled units are heavy. Failure to properly lift & support these sets can
result in serious personal injury and/or equipment damage. The appropriate
rated lifting devices and methods must be used for & during lifting
operations.
Exposure to excessive noise can cause permanent hearing damage.
It is the end users’ responsibility to identify the required legal
requirements, ensuring the appropriate safety equipment (PPE) is
applied and noise control is in place.