![KEYTRONIX I-SAD 19](http://html1.mh-extra.com/html/keytronix/i-sad-19-s/i-sad-19-s_operating-instructions-manual_1962626065.webp)
Configuration
65
M I/O and MIO commands: applies to MI/O and MI/O D-sub modules
MIO-RELAYS x x x
Activates outputs / relays
Parameters:
Module: 1 or 2
Relay: local 1..8, remote 9..16
Value: set or reset
e.g.: activate 2
nd
output of module #1:
„MIO-RELAIS 1 2 set“
MIO-MODE x
Activates the modules
Parameter: controlled/uncontrolled
MIO-SABOTAGE
Activates the sabotage monitoring for every
input
Parameters:
Module: 1 or 2
Relay: local 1..8, remote 9..16
State: yes or no
e.g. activate sabotage monitoring on the
3rd input of module #2:
„MIO-SABOTAGE 2 3 yes“
MIO-SWITCHES x y
Configuration of the settings for the
transmission line G.703 Interface.
Parameters:
SYNC A/B + Master: 5
SYNC A/B:
1
Equal + Master:
6
Equal:
2
e.g.: Module 1 should be configured to sync
pattern B and as master for clocking:
„MIO-SWITCHES 1 5”
MIO-INP-LOCATION
Enter location description for ports.
Module number
Input ports: local 1..8, remote 9..16
e.g.: Input #4 of module #1 should be
named “WIEN”:
“MIO-INP-LOCATION 1 4 WIEN”
Содержание I-SAD 19"-S
Страница 17: ...I SAD Modules 17 Physical Dimensions 183 x 96 5 x 50 LxWxH mm...
Страница 22: ...I SAD Modules 22 Physical Dimensions 183 x 96 5 x 50 LxWxH mm...
Страница 30: ...Installation 30 Removing the covers remove the pre installed slot cover...
Страница 35: ...Configuration 35 6 1 2 Main menu by simply clicking the lines you will get into the submenus...
Страница 58: ...Configuration 58...
Страница 71: ...Safety Considerations 71 7 SAFETY CONSIDERATIONS...
Страница 73: ......
Страница 74: ......