![KEYTRONIX I-SAD 19](http://html1.mh-extra.com/html/keytronix/i-sad-19-s/i-sad-19-s_operating-instructions-manual_1962626011.webp)
I - SAD 19 "- S Overview
11
RS 232
Serial asynchronous interface for remote access to an unknown
device, default configuration: 9k6/N/8/1
Pin assignment:
PIN
signal direction
description
1
0
DCD
2
0
RD
3
I
TD
4
I
DTR
5
-
GND
6
0
DSR
7
I
RTS
8
0
CTS
9
-
-
OPI
Serial OPI (Operator Interface) / CLI (Command Line Interface),
fixed configuration: 115k2/N/8/1
Pin assignment:
PIN
signal direction
description
2
0
RD
3
I
TD
5
-
GND
Powersupply
42 V DC – 230 V AC wide-range power – supply, Protection class I
The I-SAD 19“ device is powered by an integrated wide-range power supply.
The device can be powered with DC or AC voltage without any
reconfiguration.
Environmental
Conditions
Operation:
-20 °C to + 70 °C
Storage conditions:
-20 °C to + 70 °C
relative humidity:
max. 80%, not condensing