OPERATING INSTRUCTIONS

Operating Instructions

-

Press the "MODE" button until the "COOL"
indicator light comes on.

-

Press the ADJUST buttons "+" or " - " to
select your desired room temperature. The
temperature can be set within a range of
17 C-30 C/62 F-88 F (or 86 F).

-

Press the "FAN SPEED" button to choose the
fan speed.

O

O

O

O

O

-

Press the "MODE" button until the "DRY"

indicator light comes on.

-

Under this mode, you cannot select a fan

speed or adjust the temperature. The fan
motor operates at LOW speed.

-

Keep windows and doors closed for the

best dehumidifying effect.

-

Do not put the duct to window.

COOL operation

-

Press the "MODE" button until the

"FAN " indicator light comes on.

-

Press the "FAN SPEED" button to

choose the fan speed. The temperature
cannot be adjusted.

-

Do not put the duct to window.

FAN operation

TIMER operation

-

Press the "MODE" button until the "HEAT"
indicator light comes on.

-

Press the ADJUST buttons "+" or " - " to
select your desired room temperature. The
temperature can be set within a range of
17 C-30 C/62 F-88 F (or 86 F).

-

Press the "FAN SPEED" button to choose the
fan speed. For some models, the fan speed
can not be adjusted under HEAT mode.

O

O

O

O

O

HEAT operation

(cooling only models without)

AUTO operation

-

When you set the air conditioner in AUTO

mode, it will automatically select cooling,
heating(cooling only models without), or
fan only operation depending on what
temperature you have selected and the
room temperature.

-

The air conditioner will control room

temperature automatically round the
temperature point set by you.

-

Under AUTO mode, you can not

select the fan speed.

FOLLOW ME/TEMP SENSING feature(optional)

To activate the Follow Me/Temp Sensing
feature, point the remote control towards
the unit and pres s the Follow Me/Temp
Sensing button. T

If the unit does not receive

the Follow Me/Temp Sensing signal during
any 7 minutes interval, the unit will beep to
indicate the Follow Me/Temp Sens ing mode
has ended.

he remote display is

actual temperature at its location. The
remote control will send this signal to the
air conditioner every 3 minutes interval
until press the Follow Me/Temp Sensing
button again.

NOTE:This feature can be activated from the
rem ote con tro l ON LY. The rem ote con trol
servesas a rem ote thermostat allowing for the
precise tem perature control at its location.

-

When the unit is on, press the

Timer button will initiate the Auto-off

stop program, the TIMER OFF

indicator light illuminates. Press the
UP or down button to select the desired
time. Press the TIMER button again
within 5 seconds, the Auto-on start
program is initiated. And the TIMER
ON indicator light illuminates. Press
the up or down button to select the
desired Auto-on start time.

-

- Press or hold the UP or D OWN

button to change the Auto time by
0.5 hour increments, up to 10 hours,
then at 1 hour increments up to 24
hours. The control will count down
the time remaining until start.

-

The system will automatically revert

back to display the previous temper-
ature setting if there is no operation
in a five seconds period.

When the unit is off, press the Timer

button to initiate the Auto-on start
program,press it again within five
seconds will initiate the Auto-off stop
program.

Error codes and protection code:
E1-

E2-

E3-

E4-

P1-

Room temper ature sensor error-
Unplug the unit and plug it back in.
If error r epeats, call for service.
Evaporator temperature sensor error-
Unplug the unit and plug it back in.
If error r epeats, call for service.
Condenser temperature sensor error-
Unplug the unit and plug it back in. If error
repeats , call for serv ice (on some models).

error-

Unplug the unit and plug it back in.
If error r epeats, call for service.
Bottom tray is full - Connect the
drain hose and drain the collected
water away. If protection repeats, call
for service.

Display panel communication

Содержание REFURBISHED R-KSTAP12B

Страница 1: ...properly Just a little preventative care on your part can save you a great deal of time and money over the life of your air conditioner Before operating this product please read the instructions caref...

Страница 2: ...upervision be applicable for the European Countries This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or the authorised service...

Страница 3: ...tallation 12 Water drainage 13 Care and maintenance 14 Trouble shooting 15 AIR CONDITIONER FEATURES CARE AND MAINTENANCE TROUBLESHOOTING TIPS OPERATING INSTRUCTIONS INSTALLATION INSTRUCTIONS IDENTIFIC...

Страница 4: ...at least free of charge to the user D As old products contain valuable resources they can be sold to scrap metal dealers Wild disposal of waste in forests and landscapes endangers your health when haz...

Страница 5: ...d covers Never use this appliance if it is not working properly or if it has been dropped or damaged Never use the plug to start and stop the unit Always use the switch on the control panel Do not cov...

Страница 6: ...e gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance Avoid fire hazard or electric shock Do not use an extension cord or an adaptor plug Do not remove any pr...

Страница 7: ...Upper air intake 12 Fig 1 13 1 2 4 Fig 2 5 7 9 8 15 14 13 12 5 Upper air filter Behind the grille 6 10 11 Air outlet Drain outlet only for Pump heating model Power cord outlet Power cord buckle Used o...

Страница 8: ...l Selects the appropriate operating mode Each time you press the button a mode is selected in a sequence that goes from AUTO COOL DRY FAN and HEAT cooling only models without The mode indicator light...

Страница 9: ...ow Me Temp Sensing signal during any 7 minutes interval the unit will beep to indicate the Follow Me Temp Sensing mode has ended he remote display is actual temperature at its location The remote cont...

Страница 10: ...usted automatically When the Power is ON the louver opens fully Press the SWING button on the panel or remote controller to initiate the Auto swing feature The louver willl swing up and down automatic...

Страница 11: ...or outlet of the unit Allow 30cm to 100cm of space from the wall with for efficient air conditioning Your window slider kit has been designed to fit most standard Vertical and horizontal window appli...

Страница 12: ...width of window is less than 26 5 inches Open the window sash and place the window slider kit on the window stool Fig 9 3 Cut the foam seal adhesive type to the proper length and attach it on the top...

Страница 13: ...w sash and place the window slider kit on the window stool See Fig 13 3 Cut the foam seal adhesive type to the proper length and attach it on the top of the window Shown as in Fig 14 4 Close the slidi...

Страница 14: ...BEND THE EXHAUST HOSE SEE Fig 19 12 Fig 16a Fig 17 Fig 19 Not applicable to the units without adaptor A expansion plugs and wooden screws of Accessories 1 Prepare a hole in the wall Install the wall E...

Страница 15: ...rmined level Carefully move the unit to a drain location remove the bottom drain plug and let the water drain away Fig 22 Reinstall the bottom drain plug and restart the machine until the P1 symbol di...

Страница 16: ...d forming Stop the appliance and unplug it wrapped the cord and bundle it with the tape Fig 25 Remove the batteries from the remote controller Clean the air filter and reinstall it Place the open end...

Страница 17: ...re Cooling mode The windows or doors in the room are not closed There are heat sources inside the room Exhaust air duct is not connected or blocked Temperature setting is too high Air filter is blocke...

Отзывы: