background image

Do not, under any
circumstances, cut,
remove, or bypass
the grounding prong.

Power supply cord
with 3-prong grounding plug
and current detection device

Grounding type wall
receptacle

WARNING

NOTE:

The power supply cord with this air 
conditioner contains a current detection 
device designed to reduce the risk of fire.
Please refer to the section Operation
of Current Device for details.In the event 
that the power supply cord is damaged, 
it cannot be repaired-it must be replaced 
with a c

  ord f rom t he P roduct M anufacturer.  

Avoid fire hazard or electric shock. Do not
use an extension cord or an adaptor plug. 
Do not remove any prong from the power 
cord. 

WARNING

For Your Safety

WARNING

Prevent Accidents

WARNING

Electrical Information

Do not store or use gasoline or other flammable vapors and liquids in the vicinity  
of this or any other appliance.

Operation of Cur rent Device

(Applicable to the unit adopts current detection 
device only )

The power supply cord contains a current device that senses 
damage to the power cord. To test your power supply cord do 
the following:
1. Plug in the Air Conditioner.
2. The power supply cord will have TWO buttons on the plug 
    head. Press the TEST button, you will notice a click as the 
    RESET button pops out.
3. Press the RESET button, again you will notice a click as 
    the button engages.
4. The power supply cord is now supplying electricity to the 
    unit. (On some products this it also indicated by a light on 
    the plug head.)

3

To reduce the risk of fire, electrical shock, or injury to persons when using your
air conditioner, follow basic precautions, including the following:
    Be sure the electrical service is adequate for the model you have chosen. This
    information can be found on the serial plate, which is located on the side of the
    the cabinet and behind the grille.
    If the air  conditioner i s t o b e in stalled in  a w indow, yo

  u w ill pr obably w ant to  cl ean  

    both sides of  the g lass f irst. I f th e w indow is  a tri ple-track ty pe w ith a  sc reen pa nel
    included, remove the screen completely before installation.
    Be sure the  air c onditioner h as b een s ecurely a nd c orrectly in stalled a ccording to 
    the installation instructions in this manual. Save this manual for possible future
    use in removing or installing this unit.
    When handling the  air  conditioner,  be  careful  to  avoid  cuts f rom s harp m

  etal f ins

    on front and rear coils. 
   

The complete electical rating of your new room air conditioner is stated on the 
serial plate. Refer to the rating when checking the electrical requirements.
     Be sure the air conditioner is properly grounded. To minimize shock and fire 
     hazards, proper grounding is important. The power cord is equipped with a 
     three-prong grounding plug for protection against shock hazards.
     Your air conditioner must be used in a properly grounded wall receptacle. If the 
     wall receptacle you intend to use is not adequately grounded or protected by a 
     time delay fuse or circuit breaker, have a qualified electrician install the proper 
     receptacle. Ensure the receptacle is accessible after the unit installation.
     Do not run air conditioner without side protective cover in place.This could 
     result in mechanical damage within the air conditioner.
     

Do not use an extension cord or an adapter plug.

IMPORTANT SAFETY INSTRUCTIONS

    Do not use this device to turn the unit on or off.
    Always make sure the RESET button is pushed in for 
    correct operation.
    The power supply must be replaced if it fails reset when 
    either the TEST button is pushed, or it cannot be reset. A 
    new one can be obtained from the product manufacturer.
    If power supply cord is damaged, it cannot be repaired. It 
    MUST be replaced by one obtained from the product 
    manufacturer. 

NOTE:

NOTE:

This air conditioner is designed to be operated 

            under condition as follows:

Cooling 
operation

Outdoor temp: 

Indoor temp: 

Heating 
operation

Outdoor temp: 

O

O

23-76 F/

C

-5-24

Indoor temp: 

O

32-80 F/

O

0-27 C

O

O

O

O

64-109 F/18-43 C (64-125 F/18-52 C 
for special tropical models)

O

62-90 F/

O

17-32 C

Note: Performance may be reduced outside of these 
operating temperatures.

Содержание KSTHW08A

Страница 1: ...please read this manual carefully and keep it for future reference TABLE OF CONTENTS Installation Instructions 10 4 9 Normal Sounds Important Safety Instructions 1 3 Troubleshooting Tip 13 14 Air Con...

Страница 2: ......

Страница 3: ...Producto...

Страница 4: ...1 866 646 4332 1 866 646 4332 MIDEA AMERICA CORPORATION PRODUCT REGISTRATION CENTER 11800 NW 100 ROAD STE 4 MEDLEY FL 33178 1037...

Страница 5: ...xcess heat generation It may cause electric shock or fire due to heat generation Incorrect grounding may cause electric shock It may cause fire and electric shock It may cause fire It may cause explos...

Страница 6: ...ters maycause failure It contains contaminants and could make you sick Stop operation and close the window in storm or hurricane Do not use strong detergent such as wax or thinner but use a soft cloth...

Страница 7: ...he window is a triple track type with a screen panel included remove the screen completely before installation Be sure the air conditioner has been securely and correctly installed according to the in...

Страница 8: ...d Parts Gather the required tools and parts before starting installation Read and follow the instructions provided with any tools listed here TOOLS NEEDED Flat blade and Phillips screwdrivers Tape mea...

Страница 9: ...harp instruments rubbing alcohol flammable fluids or abrasive cleaners to remove tape or glue These products can damage the surface of your air conditioner Handle the air conditioner gently 1 Remove t...

Страница 10: ...the top channel on top of the air conditioner cabinet lining up the three holes in the top channel with the three holes on top of the air conditioner cabinet 3 Using three pan head Phillips thread cu...

Страница 11: ...to drill one hole through the hole in the middle of top rail and into the window frame Attach cabinet to window with one 10 x 3 4 or 1 2 round head Phillips screw FIG 11 Place two safety locks into t...

Страница 12: ...ront of panel with front panel screws FIG 17 8 Plug into a grounded 3 prong outlet 9 Press RESET on the power supply cord Through the Wall Cabinet Installation Option 1 wood metal or plastic molding W...

Страница 13: ...n to the outside The cabinet should slop at least half a bubble towards the rear 4 Reuse the insulation to seal opening between cabinet and frame 5 Use existing holes in sides and top of cabinet and s...

Страница 14: ...ill be automatically maintained O O O O anywhere between 62 F 17 C and 86 F 30 C If you want the display to read the actual room temperature see To Operate on Fan Only section Sound of Rushing Air At...

Страница 15: ...selected temperature This ends the Sleep mode and the unit will continue to operate as originally programmed The Sleep mode program can be cancelled at any time during operation by pressing the Sleep...

Страница 16: ...during this time The control is capable of displaying temperature in degrees Fahrenheit or degrees Celsius To convert from one to the other press and hold the Left and Right Temp Timer buttons at the...

Страница 17: ...of defective workman ship or materials in this appliance Solution Air conditioner does not start Wall plug disconnected Push plug firmly into wall outlet House fuse blown or circuit breaker tripped Re...

Страница 18: ...ing Water dripping INSIDE when unit is cooling Improper installation Tilt air conditioner slightly to the outside to allow water drainage Refer to installation instructions check with installer Dirty...

Страница 19: ......

Страница 20: ...The design and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details...

Страница 21: ...para instalaci n 4 17 Normales Sonidos 18 Instrucciones importantes de seguridad 1 3 Consejo de soluci n para problemas 21 22 Rasgo de aire acondicionado 18 20 Cuidado y limpio 20 21 Plazo De Garant...

Страница 22: ...ica o incendio por la generaci n del calor La tierra incorrecto podr a causar una descarga el ctrica Podr a causar incendio u descarga el ctrica Podr a causar incendio Podr a causar una explosion ince...

Страница 23: ...ndio y una descarga el ctrica lo cual producir a lesiones Detenga el funcionameinto y cierre la ventana en la tormenta o hurac n No utilice detergente fuerte como cera o algo m s delgado sino usa un p...

Страница 24: ...la inclu do remueva la pantalla completamente antes de la instalaci n Aseg rese de que el aire acondicionado est instalado a una manera segura y correcta seg n las instrucciones de intalaci n en este...

Страница 25: ...aqu HERRAMIENTAS NECESARIAS Destornilladores de cabeza plana y Philips Cinta m trica Nivel Taladro y brocas de 3 16 1 8 3 32 o m s peque as Instalaci n a trav s de la pared Adem s de las herramientas...

Страница 26: ...seche recicle los materiales de empaque Retire residuos de cinta y adhesivos de las superficies antes de instalar el acondicionador de aire Coloque una peque a cantidad de detergente l quido sobre los...

Страница 27: ...aire con los tres orificios del canal superior alineados con los orificios de la parte superior del gabinete del acondicionador de aire 3 Use tres tornillos autoperforantes Philips cabeza plana de 10...

Страница 28: ...s de seguridad en los orificios ubicados en la parte inferior del gabinete y coloque dos tornillos de cierre en los cierres de seguridad del gabinete seg n se muestra Fig 12 1 1 3 Revise que el gabine...

Страница 29: ...e de 3 patas y conexi n a tierra 9 Presione RESET restablecer en el cable de alimentaci n el ctrica Instalaci n del gabinete a trav s de la pared Opci n 1 moldura de madera metal o pl stico Al usar un...

Страница 30: ...clinado al menos media burbuja hacia la parte posterior 4 Reutilice el aislamiento para sellar la apertura entre el gabinete y el bastidor 5 Use los orificios existentes de los lados y la parte superi...

Страница 31: ...o durante el ciclo de ing cool Gurgle silbido ser o do debido a refrigerante pas cantar a trav s del evaporador durante el funcionamiento normal Gorgoteo o siseo puede Hacer ping o conmutaci n Las got...

Страница 32: ...eccionada originalmente Esto termina el modo de sue o y la unidad seguir funcionando seg n lo programado originalmente El programa de modo de reposo se puede cancelar en cualquier momento durante la o...

Страница 33: ...The ventilador continuar funcionando durante este tiempo El control es capaz de mostrar la temperatura en grados Fahrenheit o grados Celsius Para pasar de una a otra mantenga pulsada la Izquierda y D...

Страница 34: ...hura o los materiales de la f brica Soluci n El aire acondicionado no funciona Enchufe de pared desconectado Presione el enchufe con mucha esfuerza en la toma de corriente El fusible domestico estrope...

Страница 35: ...ia Un seco filtro de aire aire limitado Limpie el filtro El sonido del movimiento del aire Es normal Si hace tanto ruido cambie a una opci n de FAN m s baja La temperatura fuera es demasiado alto Elig...

Страница 36: ...y reinstalaci n necesarioS delos costos de los servicios que no sean con respecto al sistema de refrigeraci n Sellado Repuestos de Midea se utilizar n y se justifican nicamente por el per odo restante...

Страница 37: ...1 866 646 4332 GARANTIA DE AIR ACONDICIONADO 16...

Страница 38: ......

Страница 39: ......

Страница 40: ...El dise o y especificaci n se publican sin previo aviso de las mejoras del producto Consulte a la agencia de ventas o el fabricante sobre m s informaciones...

Отзывы: