Banded Solution Configuration
N5261A 2-port millimeter-wave test set controller for PNA/PNA-X based configuration
N5261A-102
A set of cables for 3.5 mm connection to a 2-port N5222A or N5242A
N5261A-104
A set of cables for 3.5 mm connection to a 4-port N5222A or N5242A
N5261A-106
A set of cables for 2.4 mm connection to a 2-port N5224A/N5225A or N5244A/N5245A
N5261A-108
A set of cables for 2.4 mm connection to a 4-port N5224A/N5225A or N5244A/N5245A
N5261A-112
A set of cables for 1.85 mm connection to a 2-port N5227A or N5247A
N5262A 4-port millimeter wave test set controller for PNA/PNA-X based configuration
N5262A-104
A set of cables for 3.5 mm connection to a 4-port N5222A or N5242A
N5262A-108
A set of cables for 2.4 mm connection to a 4-port N5224A/N5225A or N5244A/N5245A
N5262A-114
A set of cables for 1.85 mm connection to a 4-port N5227A or N5247A
Millimeter-wave test set controllers for banded and single sweep
Notes
1. For the N5261A and N5262A several cable options exist for connecting OML Inc. T/R frequency extenders please refer to the option description sec-
tion for details, page 25.
2. A 2-Port PNA/PNA-X will only support 2-port banded measurements if used with a N5262A 4-port millimeter controller.
Millimeter-wave modules
Several modules are available and other special options may be configured on request. Select the appropriate quantity of modules
required for the measurement set up. To request a specially configured test module contact your local Keysight sales engineer.
The single and dual channel receiver modules are used for antenna applications or for 1-port single path S-parametermeasurements.
Transmission reflection modules (OML Inc.)
Waveguide flange
Frequency GHz
Standard transmission/
reflection modules
Transmission/reflection mod-
ules with 25 dB mechanical
attenuator
Transmission/reflection modules
with 15 dB LO and RF amplifier
1
WR15
50 - 75
N5256AW15 - STD
N5256AW15 - 001
N5256AW15 - 002
WR12
60 - 90
N5256AW12 - STD
N5256AW12 - 001
N5256AW12 - 002
WR10
75 - 110
N5256AW10 - STD
N5256AW10 - 001
N5256AW10 - 002
WR08
90 - 140
N5256AW08 - STD
N5256AW08 - 001
N5256AW08 - 002
WR06
110 - 170
N5256AW06 - STD
N5256AW06 - 001
N5256AW06 - 002
WR05
140 - 220
N5256AW05 - STD
N5256AW05 - 001
N5256AW05 - 002
WR03
220 - 325
N5256AW03 - STD
N5256AW03 - 001
N5256AW03 - 002
WR02.2
325 - 500
N5256AW02 - STD
Not available
N5256AW02 - 002
2
Extended WR12
56 - 94
N5256AX12 - STD
N5256AX12 - 001
Available on request
1. Note the modules with the RF/LO amplifiers are for antenna applications that include a cable loss of 15 dBm to the module from the port of the test
set controller being used. Do not connect these directly to the test set controller port with the standard 48 inch cable, use a 15 dB pad if needed.
2. These modules require an external DC power supply (e.g. U8001A) when using them with the N5260A.
3. For transmission reflection modules with both the 25 dB mechanical attenuator and the 15 dB LO and RF amplifier order N5256AWxx-003. Not avail-
able for N5256AW02.
IMD transmission reflection modules (OML Inc.)
Waveguide flange
Frequency GHz
IMD module product number
WR12
60 - 90
N5256AW12 - IMD
Extended WR12
56 - 94
N5256AX12 - IMD
WR10
75 - 110
N5256AW10 - IMD
Notes
1. Note the above modules maybe used to make as IMD measurements using Option 087 measurement class for the PNA-X
2. It is currently in banded mode only.
3. The above option requires the use of a 4-port controller N5262A.
4. The access to the swept IMD application in millimeter-wave mode requires an upgrade to Windows 7.0.
5. Requires N5260A-501 cable set and an additional 20 GHz 3.5 mm (male-male) RF cable for connecting the second source. The additional cable may
be purchased as a separate part number 8121-1221.
16 | Keysight | Antenna Test – Selection Guide