Next Steps
Performing Channel Deskew
Part of what the MultiScope control software provides is the ability to deskew
measured waveforms. You can deskew signals between oscilloscope frames, and
optionally, you can deskew the channels within an oscilloscope.
The hardware for performing channel deskew is included in the N2164A
UXR-Series Multi-Frame Base Kit. The parts used to perform channel deskew are:
These parts are used to create a long cable that can be connected from
Cal Out
to
each input channel in the MultiScope system.
Part number
Qty
Description
54964-61632
2
1 m phase-stable cable
1250-2818
2
Right-angle male to female SMA adapter
1250-3758
1
Female/female SMA adapter 3.5 mm (f)
1250-3347
1
Push-on male SMA to female SMA adapter
Cal Out
Channel Deskew Connections
(Front)
1250-3758
SMA adapter
1250-2818
right-angle
SMA adapter
1250-2818
right-angle
SMA adapter
54964-61632
cable
54964-61632
cable
1250-3377 push-on SMA adapter
Содержание MultiScope UXR Series
Страница 1: ...Keysight UXR Series MultiScope Hardware Configuration Guide ...
Страница 6: ...6 Keysight UXR Series MultiScope Hardware Configuration Guide ...
Страница 8: ...8 Keysight UXR Series MultiScope Hardware Configuration Guide ...
Страница 10: ...10 Keysight UXR Series MultiScope Hardware Configuration Guide 1 UXR Series MultiScope System Requirements ...
Страница 16: ...16 Keysight UXR Series MultiScope Hardware Configuration Guide 2 Two Oscilloscope System ...
Страница 28: ...28 Keysight UXR Series MultiScope Hardware Configuration Guide 4 Next Steps ...
Страница 30: ...30 Keysight UXR Series MultiScope Hardware Configuration Guide Index ...