Before connecting the follower #2 through follower #4 oscilloscopes, first follow
the instructions for connecting a two-oscilloscope rack mount system in
“Connecting the Oscilloscopes"
Then, for each of the oscilloscopes from follower #2 to follower #4, using the parts
in a N2165A (add one) expansion kit, follow these instructions:
1
Remove the SMA 50
Ω
terminator (1250-3745) from the power divider output
that will be used for the oscilloscope.
2
Connect one 54964-61632 cable between the power divider output and the
oscilloscope’s
Sample_CLK_In
input.
3
Connect one 54964-61632 cable between the previous oscilloscope’s
Trig Out
connector to this oscilloscope’s
Aux Trig In
connector.
4
Connect one 54964-61632 cable between the previous oscilloscope’s
Reference CLK Out
connector to this oscilloscope’s
Reference CLK In
connector.
5
Connect the oscilloscope to the Leader oscilloscope (or external host
computer) through the desired remote interface connection (LAN, USB, etc.).
6
Содержание MultiScope UXR Series
Страница 1: ...Keysight UXR Series MultiScope Hardware Configuration Guide ...
Страница 6: ...6 Keysight UXR Series MultiScope Hardware Configuration Guide ...
Страница 8: ...8 Keysight UXR Series MultiScope Hardware Configuration Guide ...
Страница 10: ...10 Keysight UXR Series MultiScope Hardware Configuration Guide 1 UXR Series MultiScope System Requirements ...
Страница 16: ...16 Keysight UXR Series MultiScope Hardware Configuration Guide 2 Two Oscilloscope System ...
Страница 28: ...28 Keysight UXR Series MultiScope Hardware Configuration Guide 4 Next Steps ...
Страница 30: ...30 Keysight UXR Series MultiScope Hardware Configuration Guide Index ...