background image

Notices

Copyright Notice

© 

Keysight Technologies 2019

No part of this manual may be reproduced in 
any form or by any means (including elec-

tronic storage and retrieval or translation into 
a foreign language) without prior agreement 
and written consent from Keysight Technolo-
gies as governed by United States and inter-

national copyright laws.

Manual Part Number

M9601-90000

Edition

Edition 1, October 2019

Edition 2, December 2019

Published by:

Keysight Technologies Japan K.K.
9-1, Takakura-cho, Hachioji-shi, Tokyo 
192-0033 Japan

Regulatory Compliance

This product has been designed and tested in 

accordance with accepted industry standards, 
and has been supplied in a safe condition. To 

review the Declaration of Conformity, go to 

www.keysight.com/go/conformity

.

Warranty

THE MATERIAL CONTAINED IN THIS DOCU

-

MENT IS PROVIDED “AS IS,” AND IS SUBJECT 

TO BEING CHANGED, WITHOUT NOTICE, IN 
FUTURE EDITIONS. FURTHER, TO THE MAXI

-

MUM EXTENT PERMITTED BY APPLICABLE 
LAW, KEYSIGHT DISCLAIMS ALL WARRAN

-

TIES, EITHER EXPRESS OR IMPLIED, WITH 

REGARD TO THIS MANUAL AND ANY INFOR

-

MATION CONTAINED HEREIN, INCLUDING 
BUT NOT LIMITED TO THE IMPLIED WAR

-

RANTIES OF MERCHANTABILITY AND FIT

-

NESS FOR A PARTICULAR PURPOSE. 

KEYSIGHT SHALL NOT BE LIABLE FOR 
ERRORS OR FOR INCIDENTAL OR CONSE

-

QUENTIAL DAMAGES IN CONNECTION WITH 

THE FURNISHING, USE, OR PERFORMANCE 
OF THIS DOCUMENT OR OF ANY INFORMA

-

TION CONTAINED HEREIN. SHOULD KEY

-

SIGHT AND THE USER HAVE A SEPARATE 
WRITTEN AGREEMENT WITH WARRANTY 

TERMS COVERING THE MATERIAL IN THIS 
DOCUMENT THAT CONFLICT WITH THESE 

TERMS, THE WARRANTY TERMS IN THE SEP

-

ARATE AGREEMENT SHALL CONTROL.

KEYSIGHT TECHNOLOGIES DOES NOT WAR-

RANT THIRD-PARTY SYSTEM LEVEL (COMBI-

NATION OF CHASSIS, CONTROLLERS, 
MODULES, ETC.) PERFORMANCE, SAFETY, 

OR REGULATORY COMPLIANCE, UNLESS 
SPECIFICALLY STATED.

Technology Licenses 

The hardware and/or software described in 
this document are furnished under a license 
and may be used or copied only in accordance 
with the terms of such license.

U.S. Government Rights

The Software is “commercial computer soft

-

ware,” as defined by Federal Acquisition Reg

-

ulation (“FAR”) 2.101. Pursuant to FAR 12.212 

and 27.405-3 and Department of Defense FAR 

Supplement (“DFARS”) 227.7202, the U.S. 
government acquires commercial computer 

software under the same terms by which the 
software is customarily provided to the public. 
Accordingly, Keysight provides the Software 

to U.S. government customers under its stan

-

dard commercial license, which is embodied 
in its End User License Agreement (EULA), a 
copy of which can be found at 

http://

www.keysight.com/find/sweula

. The license 

set forth in the EULA represents the exclusive 
authority by which the U.S. government may 
use, modify, distribute, or disclose the Soft

-

ware. The EULA and the license set forth 
therein, does not require or permit, among 

other things, that Keysight: (1) Furnish techni

-

cal information related to commercial com

-

puter software or commercial computer 
software documentation that is not customar

-

ily provided to the public; or (2) Relinquish to, 

or otherwise provide, the  government rights 

in excess of these rights customarily provided 
to the public to use, modify, reproduce, 
release, perform, display, or disclose com

-

mercial computer software or commercial 
computer software documentation. No addi

-

tional government requirements beyond those 
set forth in the EULA shall apply, except to the 
extent that those terms, rights, or licenses are 
explicitly required from all providers of com

-

mercial computer software pursuant to the 

FAR and the DFARS and are set forth specifi

-

cally in writing elsewhere in the EULA. Key

-

sight shall be under no obligation to update, 
revise or otherwise modify the Software.  With 
respect to any technical data as defined by 

FAR 2.101, pursuant to FAR 12.211 and 
27.404.2 and DFARS 227.7102, the U.S. gov

-

ernment acquires no greater than Limited 
Rights as defined in FAR 27.401 or DFAR 

227.7103-5 (c), as applicable in any technical 
data.

Safety Summary

The following general safety precautions must 

be observed during all phases of operation, 
service, and repair of this product. Failure to 

comply with these precautions or with specific 
warnings elsewhere in this manual may impair 

the protections provided by the product. In 
addition, it violates safety standards of design, 
manufacture, and intended use of the product. 
Keysight Technologies assumes no liability for 

customer’s failure to comply with these 

requirements.
- Do not use this product in any manner not 
specified by the manufacturer. The protective 

features of this product may be impaired if it is 

used in a manner not specified in the opera-
tion instructions.
- This product is INDOOR USE product.
- This product complies with POLLUTION 
DEGREE II defined in IEC 61010-1.

Содержание M9601A

Страница 1: ...Keysight M9601A PXIe Precision Source Measure Unit Startup Guide...

Страница 2: ...the same terms by which the software is customarily provided to the public Accordingly Keysight provides the Software to U S government customers under its stan dard commercial license which is embod...

Страница 3: ...trument in such an environment constitutes a definite safety hazard DO NOT REMOVE COVERS No operator serviceable parts inside Refer servicing to qualified personnel To prevent electrical shock do not...

Страница 4: ...AUTION notice until the indicated conditions are fully understood and met WARNING A WARNING denotes a hazard It calls atten tion to an operating procedure or practice that if not correctly performed o...

Страница 5: ...Shipment Contents 11 Step 3 Install the Software 12 Requirements 12 Installation Process 12 Step 4 Install the Module 13 Step 5 Verify Operation of the Module 15 To Check Communication 15 To Update th...

Страница 6: ...Guarding 27 Installing Interlock Circuit 29 Maintenance 32 Cleaning 32 Self Test 33 Self Calibration 33 Calibration 34...

Страница 7: ...MSa s 10 fA 210 V 315 mA Keysight also supplies software drivers that allow you to support the modules in many popular PXI chassis and programming environments The soft front panel allows you to exerc...

Страница 8: ...or destroy electronic components Use a static safe work station to perform all work on electronic assemblies This figure shows a static safe work station using two types of ESD protection Conductive...

Страница 9: ...stall the module soon after unpacking Refer to the PXIe chassis manual for chassis installation and details Inspect for Damage After unpacking a module carefully inspect it for any shipping damage Rep...

Страница 10: ...the malfunctioning equipment Name and address of owner A Post Office box is not acceptable as a return address Product model number for example M9601A Product serial number for example MYXXXXXXXX The...

Страница 11: ...01A are shown in below Table 1 2 Consumable Supplies Model number Description Quantity M9601A PXIe Precision Source Measure Unit 1 25 MSa s 10 fA 210 V 315 mA 1 NA Quick Startup Poster 1 NA Certificat...

Страница 12: ...For setting up the controller and the PXIe chassis refer to the PXIe chassis documentation NOTE Minimum 1 GB free space is required on the controller for installing the M9601A software Installation P...

Страница 13: ...safe work station see Electrostatic Discharge ESD Precautions on page 8 And position it so that there is ample space between the chassis fan intake and exhaust vents Blockage by walls or obstructions...

Страница 14: ...o the front module guides top and bottom Slide the module to the rear of the chassis and assure that the injector ejector handle is pushed down in the unlatched downward position Slide the module comp...

Страница 15: ...ed off 2 If you are using a remote controller connect a PXIe cable between the chassis and the controller 3 Power up the chassis Verify that the chassis fans are operating and free of obstructions tha...

Страница 16: ...Panel the M960x SFP 3 Confirm that the Access indicator on the M9601A front panel turns green Refer to Figure 1 1 and Table 1 3 for LED status 4 Select Firmware Update from the Utilities menu The Fir...

Страница 17: ...es to connect and click the Connect button to launch the M960x SFP 3 Confirm that the Access indicator on the M9601A front panel turns green Refer to Figure 1 1 and Table 1 3 for LED status 4 Select S...

Страница 18: ...the M9601A front panel LED Indicators Measurement Terminals Trigger and Interlock Terminals Figure 1 1 M9601A Front Panel Access indicator Status indicator Low sense High force High sense Low force F...

Страница 19: ...current measurement WARNING There are potentially hazardous voltages 210 V present at the High force High sense and Guard terminals of this instrument To prevent electrical shock the following safety...

Страница 20: ...e Status indicator turns off Confirm that the Status indicator does not turn yellow Open the fixture cover or the shielding box access door open interlock Discharge any capacitors connected to a chann...

Страница 21: ...Ouvrez le couvercle d appareil ou la protection du bo tier de la porte d acc s verrouillage ouvert D chargez tous les condensateurs connect s au r seau D chargez tous les condensateurs connect s au r...

Страница 22: ...and frame chassis terminal These terminals are connected together by using the short bar when the M9601A is shipped from the factory The short bar must be connected to perform the grounded measurement...

Страница 23: ...input trigger must be the TTL level Intlk Interlock terminals These terminals are used to connect an interlock circuit which is installed in your test fixture or shielding box The interlock circuit c...

Страница 24: ...ge and heat to prevent electrical shock and burn Use gloves and any tool Also have enough time for discharge and radiation Afin d viter de toucher l extr mit du c ble d allongement ou l aire de la bor...

Страница 25: ...ive impact on the performance of the instrument Use coaxial cable and shielding technique to minimize the impact 2 Wire Connections or 4 Wire Connections When connecting a device under test DUT you ca...

Страница 26: ...3 2 Wire Connections and 4 Wire Connections A V High force 2 wire connections Low force Frame chassis A V High force 4 wire connections Low force Frame chassis High sense Low sense Short bar Short ba...

Страница 27: ...any of measurement circuit at any time while a floating measurement is in progress Also use accessories that comply with IEC 61010 031 All terminals and the extended conductors must be isolated by us...

Страница 28: ...er to the configuration guide 5992 4193EN Figure 1 4 Guard Technique for Grounded Measurement NOTE Low force signal comes from the outer shield of the HF connector In the grounded measurement the oute...

Страница 29: ...ding box The interlock circuit is important and necessary to prevent electrical shock when the user touches the measurement terminals Figure 1 5 Interlock Circuit WARNING Hazardous voltage instrument...

Страница 30: ...that the switches close when the access door is closed and open when the access door is opened See Figure 1 6 for the switch dimensions 2 Mount a BNC connector onto your shielding box Be sure that the...

Страница 31: ...Edition 2 31 Installing Interlock Circuit Figure 1 6 Dimension of the Interlock Switch Keysight N1254A 402 3 1 35 6 8 1 14 NC NO COM 6 4 22 2 27 8 2 8 6 3 15 9 18 8 4 75 10 3 4 3 2 8 2 8 3 2 10 3 2 8...

Страница 32: ...emical solvents Do not attempt to clean internally To clean the connectors use alcohol in a well ventilated area Allow all residual alcohol moisture to evaporate and the fumes to dissipate prior to en...

Страница 33: ...ides the self calibration function to maintain the measurement performance If the environmental temperature changes 5 C or more perform the self calibration This is effective for the accurate measurem...

Страница 34: ...the Run Self Cal button Calibration Calibration and adjustments must be performed periodically so that the instrument can meet its specifications and keep good condition It is recommended to perform t...

Страница 35: ......

Страница 36: ...This information is subject to change without notice Keysight Technologies 2019 Edition 2 December 2019 M9601 90000 M9601 90000 www keysight com...

Отзывы: