Calibration Procedures
3
Keysight E3631A Service Guide
69
CC Load Regulation
This test measures the immediate change in output current resulting from a
change in the load from full rated output voltage to short circuit.
1
Turn off the power supply and connect the output to tested as shown in Figure
3-1 with the digital voltmeter connected across the 0.1
W
current monitoring
resistor (R
M
).
2
Turn on the power supply and select the desired output to be tested using the
meter and adjust selection key on the front panel. Enable the outputs and set
the display to the limit mode. When the display is in the limit mode, program
the voltage to the maximum programmable value and the current to the full
rated value (see
3
Operate the electronic load in constant voltage mode and set its voltage to the
full rated value of the output to be tested (see
annunciator is on. If it is not, adjust the load so that the output voltage drops
slightly. Record the current reading by dividing the voltage reading on the
digital voltmeter by the resistance of the current monitoring resistor.
4
Operate the electronic load in short (input short) mode. Record the current
reading within two seconds by dividing the voltage reading on the digital
voltmeter by the resistance of the current monitoring resistor. The difference
between the current readings in step (3) and (4) is the load regulation current.
The difference of the readings during the immediate change should be within
the limit specified below for each output tested.
5
Repeat steps (1) through (4) for the remaining outputs.
Output
Difference
+6V Output
0.75 mA
+25V Output
0.35 mA
-25V Output
0.35 mA
Содержание E3631A
Страница 1: ...Keysight E3631A Triple Output DC Power Supply Service Guide ...
Страница 18: ...18 Keysight E3631A Service Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK ...
Страница 22: ...Keysight E3631A Service Guide 22 THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK ...
Страница 24: ...24 Keysight E3631A Service Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK ...
Страница 26: ...26 Keysight E3631A Service Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK ...
Страница 32: ...1 Specifications 30 Keysight E3631A Service Guide Figure 1 1 Dimensions of Keysight E3631A power supply ...
Страница 33: ...Keysight E3631A Triple Output DC Power Supply Service Guide 31 2 Quick Start ...
Страница 50: ...2 Quick Start 48 Keysight E3631A Service Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK ...
Страница 67: ...Calibration Procedures 3 Keysight E3631A Service Guide 65 Figure 3 5 Transient response time ...
Страница 98: ...3 Calibration Procedures 96 Keysight E3631A Service Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK ...
Страница 101: ...Theory of Operation 4 Keysight E3631A Service Guide 97 Block Diagram ...
Страница 110: ...4 Theory of Operation 106 Keysight E3631A Service Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK ...
Страница 122: ...5 Service 118 Keysight E3631A Service Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK ...
Страница 124: ...6 Component Drawings 120 Keysight E3631A Service Guide E3631 60002 Component Locator for the Main Board Top ...
Страница 125: ...Component Drawings 6 Keysight E3631A Service Guide 121 E3631 60003 Component Locator for the Front Panel ...
Страница 126: ...6 Component Drawings 122 Keysight E3631A Service Guide E3631 60004 Component Locator for the Main Board Bottom ...
Страница 127: ...Component Drawings 6 Keysight E3631A Service Guide 123 Component Locator for the Main Board Top serial MY53xx6xxx ...
Страница 128: ...6 Component Drawings 124 Keysight E3631A Service Guide Component Locator for the Front Panel serial MY53xx6xxx ...
Страница 129: ...Component Drawings 6 Keysight E3631A Service Guide 125 Component Locator for the Main Board Bottom serial MY53xx6xxx ...
Страница 130: ...6 Component Drawings 126 Keysight E3631A Service Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK ...