background image

4

External Boot Drive for Keysight Logic Analysis Systems Installation Guide

Safety Symbols

Table 1

 Safety Symbol

CAUTION

A CAUTION notice denotes a hazard. It calls attention to an operating procedure, 

practice, or the like that, if not correctly performed or adhered to, could result in 

damage to the product or loss of important data. Do not proceed beyond a CAUTION 

notice until the indicated conditions are fully understood and met.

WARNING

A WARNING notice denotes a hazard. It calls attention to an operating procedure, 
practice, or the like that, if not correctly performed or adhered to, could result in 
personal injury or death. Do not proceed beyond a WARNING notice until the 
indicated conditions are fully understood and met.

Symbol

Description

Direct current

Alternating current

Both direct and alternating current

Three phase alternating current

Three phase alternating current

Earth ground terminal

Protective earth ground terminal

Frame or chassis ground terminal

Terminal is at earth potential

Содержание 16900 series

Страница 1: ...Installation Guide External Boot Drive for Keysight Logic Analysis Systems...

Страница 2: ...icense and may be used or copied only in accordance with the terms of such license Restricted Rights Legend If software is for use in the performance of a U S Government prime contract or sub contract...

Страница 3: ...ent chassis and cover must be connected to an electrical ground to minimize shock hazard The ground pin must be firmly connected to an electrical ground safety ground terminal at the power outlet Any...

Страница 4: ...ns are fully understood and met WARNING A WARNING notice denotes a hazard It calls attention to an operating procedure practice or the like that if not correctly performed or adhered to could result i...

Страница 5: ...isconnected from the mains supply when the power switch is in the standby position In position of a bi stable push switch Out position of a bi stable push switch Equipment protected throughout by DOUB...

Страница 6: ...for Keysight Logic Analysis Systems Installation Guide Ionizing radiation CAT I IEC Measurement Category I CAT II Measurement Category II CAT III Measurement Category III CAT IV Measurement Category...

Страница 7: ...e compliance with the Safety requirements The C tick mark is a registered trademark of the Spectrum Management Agency of Australia This signifies compliance with the Australia EMC Framework regulation...

Страница 8: ...8 External Boot Drive for Keysight Logic Analysis Systems Installation Guide...

Страница 9: ...Step 5 Install the SATA interface adapter 22 Step 6 Replace the CPU tray 24 Step 7 Replace the cover 24 Step 8 Connect and power up the external boot drive 24 Step 9 Power up the logic analysis system...

Страница 10: ...ation Guide Contents Step 6 Replace the front panel assembly 36 Step 7 Replace the cover 36 Step 8 Connect and power up the external boot drive 36 Step 9 Power up the logic analyzer 37 Step 10 Recover...

Страница 11: ...rive option Option 009 and have ordered this external boot drive as a replacement or extra additional drive the frame s internal hard disk drive has already been removed and the SATA interface adapter...

Страница 12: ...stems will need to image the external drive by using the recovery software disk that was shipped with your original system Begin with Step 1 Prepare the instrument for disassembly on page 13 CAUTION E...

Страница 13: ...ou are running remote desktop click Start Settings Windows Security Shut Down This software power off does the following Closes all programs that are running WARNING Hazardous voltages exist on the po...

Страница 14: ...own Clicking the yes button results in the above events Clicking no will prevent the shutdown and not answering the dialog box neither clicking Yes or No will have no effect Further short presses on t...

Страница 15: ...cover 1 Using a Torx T20 screwdriver remove the handle assembly 2 Using a Torx T10 screwdriver remove 3 screws that secure the cover to the chassis 3 Slide the cover back and up to remove CAUTION Whe...

Страница 16: ...rews from the back of the CPU tray using a Torx T10 screwdriver CAUTION Before removing the CPU tray after the cover is removed attach a grounding wrist strap to the chassis CAUTION Do not loosen the...

Страница 17: ...stems Installation Guide 17 Installation on 16900 Series Logic Analysis Systems 1 3 Use the tray levers to pry and disconnect the CPU board from the module interface board and slide the tray out being...

Страница 18: ...module interface board 2 Remove 9 screws from the back of the CPU tray using a Torx T10 screwdriver CAUTION Do not loosen the other screws on the rear sheet metal they position the rear sheet metal wi...

Страница 19: ...rnal Boot Drive for Keysight Logic Analysis Systems Installation Guide 19 Installation on 16900 Series Logic Analysis Systems 1 3 Slide the tray out being careful not to catch the loose cables on anyt...

Страница 20: ...the IDE 80 wire cable and the power 4 wire cable from the internal hard disk drive 2 Remove the internal hard disk drive cables a Disconnect the IDE cable from the motherboard and remove it b If you h...

Страница 21: ...ms Installation Guide 21 Installation on 16900 Series Logic Analysis Systems 1 3 Using a Torx T15 screwdriver remove the 4 screws that secure the hard drive to the hard drive plate These screws are ac...

Страница 22: ...as shown in the following figure and remove the filler panel 3 To install the SATA interface adapter ensure that the tab at the bottom of the card is aligned with the slot in the bottom of the CPU tra...

Страница 23: ...position so there is adequate room to disconnect and reconnect the SATA cable after the installation is complete 6 Swing the plate back into place 7 Replace the screw s NOTE If you do not adjust the i...

Страница 24: ...n page 15 Step 8 Connect and power up the external boot drive 1 If the eSATA cable is not already connected to the port on the SATA interface adapter in the 16900 series logic analysis system frame do...

Страница 25: ...external drive will light up to show that the drive is recognized and is active The new E5862A external drive must be imaged prior to use to be compatible with the legacy 16900A 16902A or 16903A frame...

Страница 26: ...erating system Follow the instructions that come with the recovery DVD 2 Install the Keysight Logic Analyzer application software Follow the installation upgrade instructions provided on the web downl...

Страница 27: ...re install software 38 For a logic analysis system that runs the Windows 7 operating system system serial numbers of MY51420101 or higher If you ordered the E5862A external boot drive conversion kit...

Страница 28: ...tems to You will need to image the external drive by using the recovery software disk that was shipped with your original system Begin with Step 8 Connect and power up the external boot drive on page...

Страница 29: ...Down or if you are running remote desktop click Start Settings Windows Security Shut Down This software power off does the following Closes all programs that are running WARNING Hazardous voltages ex...

Страница 30: ...down Clicking the yes button results in the above events Clicking no will prevent the shutdown and not answering the dialog box neither clicking Yes or No will have no effect Further short presses on...

Страница 31: ...2 Using a Torx T10 screwdriver remove 6 screws that secure the cover to the chassis Optional for 16901A Removing the shroud may make it easier to remove and replace the cover In this case remove 4 T10...

Страница 32: ...motherboard Display cable from the display board or from the motherboard if applicable use care when disconnecting to avoid damage Touchscreen cable from the touch screen controller board if the frame...

Страница 33: ...ive cables from the hard drive 3 Using a Torx T10 screwdriver remove the 4 screws that secure the hard drive to the hard drive bracket These screws are accessible through holes in the bottom of the tr...

Страница 34: ...ear of the frame 2 Remove the filler panel 3 To install the SATA interface adapter ensure that the tab at the bottom of the card is aligned with the slot in the bottom of the CPU tray between the moth...

Страница 35: ...external port on the interface card This adjusts the interface card s position so there is adequate room to disconnect and reconnect the SATA cable after the installation is complete 6 Replace the sc...

Страница 36: ...Remove the cover on page 31 Step 8 Connect and power up the external boot drive 1 If the eSATA cable is not already connected to the port on the SATA interface adapter in the 16800 Series or 16901A l...

Страница 37: ...e operating system frame drivers and application software installed In this case you are done with the external disk installation procedure and should continue with the first time set up procedures in...

Страница 38: ...e appropriate recovery DVD restore the operating system Follow the instructions that come with the recovery DVD 3 Install the Keysight Logic Analyzer application software Follow the installation upgra...

Страница 39: ...onment Characteristics Shock 80 g 64 in sec Temperature 5 C to 55 C 41 F to 131 F Humidity 5 to 95 relative humidity non condensing Altitude 304 8 to 3 048 m 1 000 to 10 000 ft Vibration Linear 10 to...

Страница 40: ...Shock 54 g 292 in sec Temperature 40 C to 65 C 40 F to 149 F Humidity 5 to 95 relative humidity non condensing Altitude 304 8 to 12 192 m 1 000 to 40 000 ft Vibration Low frequency 5 to 20 Hz 0 195 in...

Страница 41: ...External Boot Drive for Keysight Logic Analysis Systems Installation Guide 41...

Страница 42: ...This information is subject to change without notice Keysight Technologies 2005 2006 2011 2014 Fifth Edition November 2014 E5862 97003 www keysight com...