background image

Notices

© Keysight Technologies, Inc.     

20

14

, 2016

No part of this manual may be 

reproduced in any form or by any 

means (including electronic storage 

and retrieval or translation into a 

foreign language) without prior 

agreement and written consent from 

Keysight Technologies, Inc. as 

governed by United States and 

international copyright laws.

Trademark Acknowledgments

Manual Part Number

U30

20

-900

13

Edition

Edition 1, 

Ju

ly

 2016

Supersedes: 

August 2014

Printed in USA/Malaysia

Published by:

Keysight Technologies

1400 Fountaingrove Parkway 

Santa Rosa, CA 95403

Warranty

THE MATERIAL CONTAINED IN THIS 

DOCUMENT IS PROVIDED “AS IS,” 

AND IS SUBJECT TO BEING 

CHANGED, WITHOUT NOTICE, IN 

FUTURE EDITIONS. FURTHER, TO 

THE MAXIMUM EXTENT PERMITTED 

BY APPLICABLE LAW, KEYSIGHT 

DISCLAIMS ALL WARRANTIES, 

EITHER EXPRESS OR IMPLIED WITH 

REGARD TO THIS MANUAL AND 

ANY INFORMATION CONTAINED 

HEREIN, INCLUDING BUT NOT 

LIMITED TO THE IMPLIED 

WARRANTIES OF 

MERCHANTABILITY AND FITNESS 

FOR A PARTICULAR PURPOSE. 

KEYSIGHT SHALL NOT BE LIABLE 

FOR ERRORS OR FOR INCIDENTAL 

OR CONSEQUENTIAL DAMAGES IN 

CONNECTION WITH THE 

FURNISHING, USE, OR 

PERFORMANCE OF THIS 

DOCUMENT OR ANY INFORMATION 

CONTAINED HEREIN. SHOULD 

KEYSIGHT AND THE USER HAVE A 

SEPARATE WRITTEN AGREEMENT 

WITH WARRANTY TERMS 

COVERING THE MATERIAL IN THIS 

DOCUMENT THAT CONFLICT WITH 

THESE TERMS, THE WARRANTY 

TERMS IN THE SEPARATE 

AGREEMENT WILL CONTROL.

Technology Licenses

The hardware and/or software 

described in this document are 

furnished under a license and may be 

used or copied only in accordance 

with the terms of such license.

U.S. Government Rights

The Software is “commercial 

computer software,” as defined 

by Federal Acquisition Regulation 

(“FAR”) 2.101. Pursuant to FAR 

12.212 and 27.405-3 and 

Department of Defense FAR 

Supplement (“DFARS”) 227.7202, 

the U.S. government acquires 

commercial computer software 

under the same terms by which 

the software is customarily 

provided to the public. 

Accordingly, Keysight provides 

the Software to U.S. government 

customers under its standard 

commercial license, which is 

embodied in its End User License 

Agreement (EULA), a copy of 

which can be found at 

http://www.keysight.com/find/sweula 

The license set forth in the EULA 

represents the exclusive authority 

by which the U.S. government 

may use, modify, distribute, or 

disclose the Software. The EULA 

and the license set forth therein, 

does not require or permit, 

among other things, that 

Keysight: (1) Furnish technical 

information related to 

commercial computer software 

or commercial computer 

software documentation that is 

not customarily provided to the 

public; or (2) Relinquish to, or 

otherwise provide, the  

government rights in excess of 

these rights customarily provided 

to the public to use, modify, 

reproduce, release, perform, 

display, or disclose commercial 

computer software or 

commercial computer software 

documentation. No additional 

government requirements 

beyond those set forth in the 

EULA shall apply, except to the 

extent that those terms, rights, or 

licenses are explicitly required 

from all providers of commercial 

computer software pursuant to 

the FAR and the DFARS and are 

set forth specifically in writing 

elsewhere in the EULA. Keysight 

shall be under no obligation to 

update, revise or otherwise 

modify the Software. With 

respect to any technical data as 

defined by FAR 2.101, pursuant 

to FAR 12.211 and 27.404.2 and 

DFARS 227.7102, the U.S. 

government acquires no greater 

than Limited Rights as defined in 

FAR 27.401 or DFAR 227.7103-5 

(c), as applicable in any technical 

data.

Safety Notices

CAUTION

 notice denotes a hazard. It 

calls attention to an operating 

procedure, practice, or the like that, 

if not correctly performed or adhered 

to, could result in damage to the 

product or loss of important data. Do 

not proceed beyond a CAUTION 

notice until the indicated conditions 

are fully understood and met. 

WARNING

 notice denotes a hazard. 

It calls attention to an operating 

procedure, practice, or the like that, 

if not correctly performed or adhered 

to, could result in personal injury or 

death. Do not proceed beyond a 

WARNING notice until the indicated 

conditions are fully understood and 

met.

Содержание U3020AS22

Страница 1: ...Multiport Test Set User s and Service Guide Notice This document contains references to Agilent Please note that Agilent s Test and Measurement business has become Keysight Technologies For more info...

Страница 2: ...oftware to U S government customers under its standard commercial license which is embodied in its End User License Agreement EULA a copy of which can be found at http www keysight com find sweula The...

Страница 3: ...Connection using Your Company s Intranet 10 Test Set Control Commands 11 Adding Instruments to the LAN Interface 17 Configuring the LAN Interface 17 Locating the Instrument 17 Configuring the GPIB Int...

Страница 4: ...nformity 40 Statement of Compliance 40 Before Applying Power 41 Connector Care and Cleaning Precautions 42 Regulatory Information 44 Instrument Markings 44 Battery Collection 45 Electrical Safety Comp...

Страница 5: ...Keysight U3020AS22 User s and Service Guide 1 U3020AS22...

Страница 6: ...e reverse path b1 4 that allow the user to connect a full 12 Port matrix There are two AUX output ports that allow the unit to connect to another multiport test set or for some other application This...

Страница 7: ...ded with the shipment Inspect the shipping container If the container or packing material is damaged it should be kept until the contents of the shipment have been checked mechanically and electricall...

Страница 8: ...al voltage Air conditioning equipment or other motor operated equipment should not be placed on the same ac line that powers the Test Set U3022AS22 maximum power is 50 W Environmental Tests The U3020A...

Страница 9: ...stomer provided lab bench or table top of adequate size and strength General RF Switch Specifications Table 1 Test Set Dimensions Item Length Weight Width 42 5 cm 16 73 in Depth 58 cm 22 83 in Height...

Страница 10: ...tics Freq Range Limits Insertion Loss dB 300 kHz to 26 5 GHz 8 0 Return Loss1 dB 1 All front panel ports when internally terminated 300 kHz to 20 GHz 10 0 20 to 26 5 GHz 6 0 Isolation dB 300 kHz to 26...

Страница 11: ...UX1 Port is switched to an A Port that port LED will display green When a Test Port or AUX2 Port is switched to a B Port that port LED will display amber When A Port and B Port are connected their res...

Страница 12: ...e LED Definitions LED Color Instrument State ATTN LAN PWR Off Green Green Instrument in ready state LAN connection established instrument has an IP address firmware download complete ATTN LAN PWR flas...

Страница 13: ...dily identifiable and is easily reached by the operator The detachable power cord is the instrument disconnecting device It disconnects the mains circuits from the mains supply before other parts of t...

Страница 14: ...est Set and your controlling computer to an active instrument LAN line Open the Internet browser application on the computer Enter this default web address on your browser application http U3020AS22 x...

Страница 15: ...meters Refer to Table5 for the commands used to control the Test Set s predefined switch configurations Measurement Setup Example With the following sequence commands a2p5 and b2p10 the Test Set will...

Страница 16: ...ted Ports are terminated 13 a1aux A Port 1 to Aux 1 unselected Ports are terminated 14 a2p1 A Port 2 to Test Port 1 unselected Ports are terminated 15 a2p2 A Port 2 to Test Port 2 unselected Ports are...

Страница 17: ...ed 43 a4p4 A Port 4 to Test Port 4 unselected Ports are terminated 44 a4p5 A Port 4 to Test Port 5 unselected Ports are terminated 45 a4p6 A Port 4 to Test Port 6 unselected Ports are terminated 46 a4...

Страница 18: ...d 72 b2p7 B Port 2 to Test Port 7 unselected Ports are terminated 73 b2p8 B Port 2 to Test Port 8 unselected Ports are terminated 74 b2p9 B Port 2 to Test Port 9 unselected Ports are terminated 75 b2p...

Страница 19: ...e terminated 101 b4p10 B Port 4 to Test Port 10 unselected Ports are terminated 102 b4p11 B Port 4 to Test Port 11 unselected Ports are terminated 103 b4p12 B Port 4 to Test Port 12 unselected Ports a...

Страница 20: ...4 unselected Ports are terminated 121 atem A Ports 1 to 4 terminated A port paths terminated 122 bterm B ports 1 to 4 terminated B port paths terminated 123 LED_GRN all green LEDs on display diagnosi...

Страница 21: ...C 2 Turn On the Test Set 3 Select IO Control icon Agilent Connection Expert from the application window Figure 5 Agilent Connection Expert Locating the Instrument Agilent Connection Expert opens with...

Страница 22: ...network for instruments 2 Select Add LAN Instrument on LAN TCPIP0 OK Agilent Connection Expert performs an automatic find of all instruments on the same subnet as the computer 3 Select the desired ins...

Страница 23: ...ert Adding Instruments to the GPIB Configuration 1 Select Add Instrument on the tool bar 2 Select GPIB Interface OK 3 Select U3020A s Address in the GPIB address drop down list OK Factory set address...

Страница 24: ...IP address it was assigned to Example The following command sets the IP address SYST COMM IPAD 169 254 149 35 The following query returns the IP address currently being used by the instrument quotes a...

Страница 25: ...n IP address from the DHCP server If a DHCP server is found it will assign a Dynamic IP address Subnet Mask and Default Gateway to the instrument When the DHCP is disable or unavailable the instrument...

Страница 26: ...5 232 4 DNS Command This command assigns the IP address of the Domain Name System DNS server Contact your network administrator to determine if DNS is being used and for the correct address Syntax SYS...

Страница 27: ...ommand This command assigns a Default Gateway for the U3020A The specified IP Address sets the Default Gateway which allows the instrument to communicate with systems that are not on the local subnet...

Страница 28: ...nes a Host Name SYST COMM LAN HOST U3020AS22 0101 The following query returns the Host Name currently being used by the instrument the quotes are also returned SYST COMM LAN HOST Typical Response U302...

Страница 29: ...ight U3020AS22 User s and Service Guide U3020AS22 Controlling the Test Set 1 Typical Response 26 For a complete list of SCPI commands refer to the Keysight L449xA RF Switch Platform User s Guide L4490...

Страница 30: ...ange RF coaxial cables with 3 5 mm connectors Equipment Setup 1 Configure PNA and Test Set as shown in Figure 7 2 Turn On the PNA and Test Set The Test Set LED Indicators should indicate the following...

Страница 31: ...he LAN connection 7 Execute the sequence command ROUT SEQ TRIG a1p1 to create A Port 1 to Test Port 1 signal path Figure 10 is representation of the S21 response trace Markers shown are not provided i...

Страница 32: ...Keysight U3020AS22 User s and Service Guide 28 U3020AS22 Performance Verification Figure 11 Typical Insertion Loss Plot Figure 12 Typical Port Isolation Plot...

Страница 33: ...e agreements for this product These servicing instructions are for use by qualified personnel only To avoid electrical shock do not perform any servicing unless you are qualified to do so Replaceable...

Страница 34: ...from the packaging in an anti static area ensuring that the correct anti static precautions are taken Two types of ESD protection are listed below Purchase acceptable ESD accessories from your local s...

Страница 35: ...and use a grounded wrist strap to prevent damage from electrostatic discharge ESD See Electrostatic Discharge Protection on page 30 Test Set System Operation Figure 13 illustrates the components and...

Страница 36: ...3 Y1154A P103 P104 P105 P106 P107 P108 Bank 4 Y1154A P103 P104 P105 P106 P107 P108 S2 S3 S4 S5 S6 S7 S8 S9 S10 S11 S12 S18 S17 S15 S13 J1 Exp Bus Port 1 TEST PORTS 34945EXT SLAVE Switch Status Displa...

Страница 37: ...all the communication between the Controller and the Test Set via LAN or GPIB connectivity 39495EXT Module This module provides the bias and control signals for the RF Switches Distribution Board The...

Страница 38: ...ing the front panel button continue with the following procedure a Remove the top cover of the instrument b Ensure that the ribbon cable and 2 wire connector are properly in place c Measure the DC vol...

Страница 39: ...resent suspect the front panel Input Port LED board or the Controller Module I O section RF Switch is Not Switching 1 If the RF Switches are not operating continue with the following procedure a Deter...

Страница 40: ...bnormal follow the steps on page 34 3 To confirm that the instrument sequences are correct access the instrument web page at http U3020AS22 xxxx xxxx last four digits of the serial number 4 On the ins...

Страница 41: ...re 14 Top View Component Locations R S2 S1 S4 S3 S6 S5 S8 S7 S10 S9 S12 S11 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 87104C x2 87106C x6 N1810UL x12 S17 S18 S19 S20 S13 S15 S16 S14 37 Keysight...

Страница 42: ...22 Service Information 1 Figure 15 Bottom View Component Locations A B Controller Module Power Supply Digital I O Relay Driver 34945 Ext 34945 Ext Slave Master Keysight U3020AS22 User s and Service Gu...

Страница 43: ...U3020AS22 Service Information Figure 16 34945 EXT Distribution Boards Master Slave Y1154A Y1154A Y1151A Y1151A Y1151A Y1151A 39 Keysight U3020AS22 User s and Service Guide...

Страница 44: ...tact Any interruption of the protective conductor inside or outside of the product is likely to make the product dangerous Intentional interruption is prohibited Always use the three prong AC power co...

Страница 45: ...th this product Failure to ensure adequate earth grounding by not using this cord may cause product damage and the risk of electrical shock This product is designed for use in Installation Category II...

Страница 46: ...se the user to dangerous voltages Disconnect the instrument from all voltage sources before opening No operator serviceable parts inside Refer servicing to qualified personnel To prevent electrical sh...

Страница 47: ...th or one slightly dampened with water to clean the external case parts Do not attempt to clean internally If flammable cleaning materials are used the material shall not be stored or left open in the...

Страница 48: ...is a registered trademark of the European Community If accompanied by a year it is when the design was proven The CSA mark is a registered trademark of the CSA International This mark designates the...

Страница 49: ...10 1 3rd Edition Acoustic statement European Machinery Directive 2022 42 EC 1 7 4 2U Acoustical noise emission LpA 70 dB Operator position Normal operation mode Per ISO 7779 EMI and EMC Compliance EMC...

Страница 50: ...entative can determine the warranty status of your unit Shipping Your Product to Keysight for Service or Repair IMPORTANT Keysight Technologies reserves the right to reformat or replace the internal h...

Страница 51: ...47 Keysight U3020AS22 User s and Service Guide...

Страница 52: ...This information is subject to change without notice Keysight Technologies 2014 2016 Edition 1 July 2016 Supersedes August 2014 www keysight com...

Отзывы: