Getting Started Guide 75
Operating Tasks
Port Configuration
Configuration Example (TxRx 4)
Setting up RFIO 4 for full duplex. (See
“RF power in full duplex mode” on
.)
Figure 5-18
Example: TxRx 4
Set up the RF Input using this menu setting or its equivalent command:
Input/Output > Input > RF Input Port > RFIO 4
Command:
:FEED:RF:PORT:INP RFIO4
Then set up the RF Output using this menu setting or its equivalent command:
Input/Output > RF Source > RF Output > RFIO 4
Command:
:FEED:RF:PORT:OUTP RFIO4