Page 22
Find us at
www.keysight.com
PNA Family Network Analyzer Upgrade Kits
(continued)
Application options
Upgrade kits are available to add options after initial purchase. To upgrade the PNA-X/PNA/PNA-L, order the corresponding
item number. The model and serial numbers of the instrument to be retrofitted are required as part of the order.
1 For measuring frequency converters, Option 082 or 083 is required.
2 Requires configurable test set for signal conditioning of noise figure measurements using standard receivers. Therefore it is not available with N522xA-200, -210,
-400 and -410.
3 Upgrading N5244A units with noise figure hardware requires serial-number prefixes of 5204 or higher, and upgrading N5245A units requires serial-number prefixes of
5205 or higher. For these two models, units with lower serial-number prefixes can be traded in for credit towards a new unit with the noise figure hardware.
4 Two-tone signal must be routed to R1 receiver after an external combiner; therefore it is not available with N522xA-200, -210, -400 and -410.
5 When used with an external signal generator, configurable test set is required to access a receiver. Therefore it is not available with N522xA-200 and -210.
6 To connect a multiport test set, configurable test set is required. Therefore it is not available with N522xA-200, -210, -400, -410, and N523xA-200, and -400.
7 The Windows 7 upgrade kit for PNAs containing CPU version 6 is model N8983A. This upgrade kit contains a new solid state drive with all of the necessary software
installed. For units with older CPUs, order the N8984A with Option PC7. This upgrade kit contains a new solid state drive and a version 7 CPU. For adding Option 090
to units with DSP version 4, add Option SP5 to the N8983A or N8984A order to get the DSP version 5.
8 A configurable test set is required for VMC measurements (to connect a reference mixer) or for SMC+Phase measurements using the comb-generator-based calibration.
When ordered with N522xA-200, -210, -400 and -410, Option 083 adds phase and delay measurements only by using SMC+Phase with a calibration mixer.
9 Optional receiver attenuators are recommended to avoid receiver compression for large-signal measurements.
10. Option 093 is a subset of Option 094; therefore they cannot be ordered together.
11. Some parameters are is restricted to 50 GHz.
Description
Required Option
For PNA-X
Series
For PNA
Series
For PNA-L
Series
User
Installable
Measurement applications
Automatic fixture removal
Windows 7 OS
7
.
N524xAU-007
N522xAU-007
N523xAU-007 Yes
Time-domain measurements
N524xAU-010
N522xAU-010
N523xAU-010 Yes
Noise figure measurements using standard receivers
Option 080
1,2
N524xAU-028
N522xAU-028
n/a
Yes
Fully-corrected noise figure measurements
for PNA-X, 2-ports
Option 080 and for N5241/42/49A, one of Op-
tions 219, 224 or H85
1
.
For N5244/45/47A, 080 and 224
N524xAU-924
3
n/a
n/a
No
Fully-corrected noise figure measurements
for PNA-X, 4-ports
Option 080 and for N5241/42/49A, one of Op-
tions 419, 423 or H85
1
.
For N5244/45/47A, 080 and 423
N524xAU-929
3
n/a
n/a
No
Frequency offset
N524xAU-080
N522xAU-080
N523xAU-080 Yes
Scalar-calibrated converter measurements
Option 080
N524xAU-082
N522xAU-082
N523xAU-082 Yes
Vector- and scalar-calibrated converter measurements
Option 080
8
N524xAU-083
N522xAU-083
n/a
Yes
Embedded LO measurements
Option 082 or 083
N524xAU-084
N522xAU-084
n/a
Yes
Gain compression application
See Footnote 1
N524xAU-086
N522xAU-086
n/a
Yes
Intermodulation distortion application
Option 080
1,4
N524xAU-087
N522xAU-087
n/a
Yes
Source phase control
See Footnote 5
N524xAU-088
N522xAU-088
n/a
Yes
Differential and I/Q devices application
Option 080 and 400, 401, 410, 417, or 419, and
Windows 7 OS
7
N524xAU-089
N522xAU-089
n/a
Yes
Spectrum analyzer
Option 080, Windows 7 OS, and
DSP version 5
7, 9
N524xAU-090 N522xAU-090
523xAU-090
Yes
Extended spectrum analyzer to 110 GHz
10
Option 090. Not available with N5241/49A or
N5221A
N524xAU-093
N522xAU-093
n/a
Yes
Extended spectrum analyzer above 110 GHz
10
Option 090. Not available with N5241/49A or
N5221A
N524xAU-094
N522xAU-094
n/a
Yes
Active hot parameters (export-controlled version)
Option 080 and 400, 400/419, or 400/419/423
N524xAU-110
n/a
n/a
Yes
Active hot parameters
11
Option 080 and 400, 400/419, or 400/419/423
N524xAU-111
n/a
n/a
Yes
Integrated true-mode stimulus application
Option 400, 401, 417, 419, or 423
N524xAU-460
N522xAU-460
n/a
Yes
N-port capabilities
See Footnote 6
N524xAU-551
N522xAU-551
N523xAU-551 Yes