Security Guide

Safety Information

The following safety precautions should be observed before using this product 
and any associated instrumentation. This product is intended for use by 
qualified personnel who recognize shock hazards and are familiar with the 
safety precautions required to avoid possible injury. Read and follow all 
installation, operation, and maintenance information carefully before using the 
product.

If this product is not used as specified, the protection provided by the equipment could be 
impaired. This product must be used in a normal condition (in which all means for protection 
are intact) only.
The types of product users are:

— Responsible body is the individual or group responsible for the use and maintenance of 

equipment, for ensuring that the equipment is operated within its specifications and 
operating limits, and for ensuring operators are adequately trained.

— Operators use the product for its intended function. They must be trained in electrical 

safety procedures and proper use of the instrument.They must be protected from electric 
shock and contact with hazardous live circuits.

— Maintenance personnel perform routine procedures on the product to keep it operating 

properly (for example, setting the line voltage or replacing consumable materials). 
Maintenance procedures are described in the user documentation.The procedures 
explicitly state if the operator may perform them. Otherwise, they should be performed only 
by service personnel.

— Service personnel are trained to work on live circuits, perform safe installations, and repair 

products.Only properly trained service personnel may perform installation and service 
procedures.

Содержание M9383B VXG-m

Страница 1: ...Security Guide Keysight M9383B VXG m Microwave Vector Signal Generator...

Страница 2: ...use modify reproduce release perform display or disclose commercial computer software or commercial computer software documentation No additional government requirements beyond those set forth in the...

Страница 3: ...s and Service Offices 9 Memory Declassification Procedure Security Terms and Definitions 12 Product Memory Sanitization 13 M9383B VXG m Microwave Vector Signal Generator 14 Disk Drive Partitioning and...

Страница 4: ...4 Keysight M9383B Microwave Signal Generator Security Guide Contents...

Страница 5: ...sible for the use and maintenance of equipment for ensuring that the equipment is operated within its specifications and operating limits and for ensuring operators are adequately trained Operators us...

Страница 6: ...any unknown circuit before measuring Operators of this product must be protected from electric shock at all times The responsible body must ensure that operators are prevented access and or insulated...

Страница 7: ...re performing any maintenance disconnect the line cord and all test cables To maintain protection from electric shock and fire replacement components in mains circuits including the power transformer...

Страница 8: ...ed as Monitoring and Control instrumentation product Do not dispose in domestic household waste To return unwanted products contact your local Keysight office or for more information see http about ke...

Страница 9: ...Is your product software up to date Periodically Keysight releases software updates to fix known defects and incorporate product enhancements To search for software updates for your product go to the...

Страница 10: ...10 Keysight M9383B Microwave Signal Generator Security Guide Safety Information Contacting Keysight...

Страница 11: ...teps necessary to declassify the products through memory sanitization or removal For additional information on a particular product the Keysight Instrument Security Database may be accessed here www k...

Страница 12: ...ion procedures include memory sanitization or memory removal or both Keysight declassification procedures are designed to meet the requirements specified in DoD 5220 22 M Chapter 8 Sanitization As def...

Страница 13: ...sses for the following Keysight product models are covered in this document Instrument M9383B VXG m Microwave Vector Signal Generator PXI Modules M9043A PXI Chassis and Frequency Reference M9037A PXIe...

Страница 14: ...of the C drive is the only part of the instrument software restored by the Instrument Recovery process You must reload any other software that you have added in the instrument The D partition is rese...

Страница 15: ...documentation User Modifiable Yes Volatile No Memory Erase Processes To uninstall the PathWave instrument driver from the controller perform the relevant procedure below To erase 1 Select Start Contr...

Страница 16: ...ing information from the SSD SSD Removal and Installation Because it is virtually impossible to completely and selectively erase all user data on a hard drive without also destroying the operating sys...

Страница 17: ...oved from the M9037A do not attempt to power it up Always install the SSD before applying power to the M9037A If you do not then the SATA selection is eliminated from the boot option list If the SSD i...

Страница 18: ...date max assembly temperature and calibration data User Modifiable No Volatile No Memory Erase Processes None this is not user accessible Memory Type 2 Memory Type Flash Memory Memory Size 128 M Bit...

Страница 19: ...cal verify date max module temperature and calibration and alignment data User Modifiable No Volatile No Memory Erase Processes None this is not user accessible Memory Type 2 Memory Type Flash Memory...

Страница 20: ...perature and calibration and alignment data User Modifiable No Volatile No Memory Erase Processes None this is not user accessible Memory Type 2 Memory Type Flash Memory Memory Size 128 M Bit Memory F...

Страница 21: ...erature and calibration and alignment data User Modifiable No Volatile No Memory Erase Processes None this is not user accessible Memory Type 2 Memory Type Flash Memory Memory Size 128 M Bit Memory Fu...

Страница 22: ...dule temperature and calibration and alignment data User Modifiable No Volatile No Memory Erase Processes None this is not user accessible Memory Type 2 Memory Type Flash Memory Memory Size 128 M Bit...

Страница 23: ...verify date max module temperature and calibration and alignment data User Modifiable No Volatile No Memory Erase Processes None this is not user accessible Memory Type 2 Memory Type Flash Memory Mem...

Страница 24: ...This information is subject to change without notice Keysight Technologies 2020 Edition 1 June 2020 M9383 90021 www keysight com...

Отзывы: