background image

Notices

© Keysight Technologies 2020
No part of this manual may be 

reproduced in any form or by any 

means (including electronic storage 

and retrieval or translation into a 

foreign language) without prior 

agreement and written consent from 

Keysight Technologies as governed by 

United States and international 

copyright laws.

Edition

Edition 2, May 2020
Published by:

Keysight Technologies 

1400 Fountaingrove Parkway

Santa Rosa, CA 95403-1738

United States

Warranty

THE MATERIAL CONTAINED IN THIS 

DOCUMENT IS PROVIDED "AS IS," 

AND IS SUBJECT TO BEING 

CHANGED, WITHOUT NOTICE, IN 

FUTURE EDITIONS. FURTHER, TO THE 

MAXIMUM EXTENT PERMITTED BY 

APPLICABLE LAW, KEYSIGHT 

DISCLAIMS ALL WARRANTIES, EITHER 

EXPRESS OR IMPLIED WITH REGARD 

TO THIS MANUAL AND ANY 

INFORMATION CONTAINED HEREIN, 

INCLUDING BUT NOT LIMITED TO THE 

IMPLIED WARRANTIES OF 

MERCHANTABILITY AND FITNESS FOR 

A PARTICULAR PURPOSE. KEYSIGHT 

SHALL NOT BE LIABLE FOR ERRORS 

OR FOR INCIDENTAL OR 

CONSEQUENTIAL DAMAGES IN 

CONNECTION WITH THE 

FURNISHING, USE, OR 

PERFORMANCE OF THIS DOCUMENT 

OR ANY INFORMATION CONTAINED 

HEREIN. SHOULD KEYSIGHT AND THE 

USER HAVE A SEPARATE WRITTEN 

AGREEMENT WITH WARRANTY 

TERMS COVERING THE MATERIAL IN 

THIS DOCUMENT THAT CONFLICT 

WITH THESE TERMS, THE WARRANTY 

TERMS IN THE SEPARATE AGREEMENT 

WILL CONTROL.

Technology Licenses

The hardware and/or software 

described in this document are 

furnished under a license and may be 

used or copied only in accordance with 

the terms of such license.

U.S. Government Rights

The Software is "commercial computer 

software," as defined by Federal 

Acquisition Regulation ("FAR") 2.101. 

Pursuant to FAR 12.212 and 27.405-3 

and Department of Defense FAR 

Supplement ("DFARS") 227.7202, the 

U.S. government acquires commercial 

computer software under the same 

terms by which the software is 

customarily provided to the public. 

Accordingly, Keysight provides the 

Software to U.S. government 

customers under its standard 

commercial license, which is embodied 

in its End User License Agreement 

(EULA), a copy of which can be found at 

http://www.keysight. com/find/sweula. 

The license set forth in the EULA 

represents the exclusive authority by 

which the U.S. government may use, 

modify, distribute, or disclose the 

Software. The EULA and the license set 

forth therein, does not require or 

permit, among other things, that 

Keysight: (1) furnish technical 

information related to commercial 

computer software or commercial 

computer software documentation that 

is not customarily provided to the 

public; or (2) relinquish to, or otherwise 

provide, the government rights in 

excess of these rights customarily 

provided to the public to use, modify, 

reproduce, release, perform, display, or 

disclose commercial computer software 

or commercial computer software 

documentation. No additional 

government requirements beyond 

those set forth in the EULA shall apply, 

except to the extent that those terms, 

rights, or licenses are explicitly required 

from all providers of commercial 

computer software pursuant to the FAR 

and the DFARS and are set forth 

specifically in writing elsewhere in the 

EULA. Keysight shall be under no 

obligation to update, revise or 

otherwise modify the Software. 

Safety Notices

A WARNING notice denotes a hazard. 

It calls attention to an operating 

procedure, practice, or the like that, if 

not correctly performed or adhered to, 

could result in personal injury or death. 

Do not proceed beyond a WARNING 

notice until the indicated conditions are 

fully understood and met.

A CAUTION notice denotes a hazard. 

It calls attention to an operating 

procedure, practice, or the like that, if 

not correctly performed or adhered to, 

could result in damage to the product  

or loss of important data. Do not 

proceed beyond a CAUTION notice until 

the indicated conditions are fully 

understood and met.

Содержание E9986E

Страница 1: ...Keysight i3070 Series 5i Inline In Circuit Test System Replacing the Power Supply ...

Страница 2: ...tware is customarily provided to the public Accordingly Keysight provides the Software to U S government customers under its standard commercial license which is embodied in its End User License Agreement EULA a copy of which can be found at http www keysight com find sweula The license set forth in the EULA represents the exclusive authority by which the U S government may use modify distribute o...

Страница 3: ... i3070 Inline In Circuit Test System Replacing the Power Supply Parts 4 i3070 Inline System E9988E 5 i3070 Lean Inline System E9988EL 10 i3070 4 mod Inline System E9986E 17 Tools required Allen key Screwdriver ...

Страница 4: ...on For i3070 Inline System E9988E E9988 61208 Omron Cosel Power Supply Bracket with DIN Rail Standard Inline E9988 61615 Cables Set for Omron Power Supply 20A Replacement Standard Inline For i3070 Lean Inline System E9988EL E9988 61209 Omron Power Supply Bracket Lean Inline EMU E9988 61616 Cables Set for Omron Power Supply 20A Replacement Lean Inline E9988 61210 Cosel Power Supply Bracket Lean Inl...

Страница 5: ...f installing the Omron 20 A AC DC power supply remove PS1 and PS2 If installing the Cosel 6 4 A AC DC power supply remove PS3 a Open the protective cover and loosen the screws to release all cables at the AC DC power supply terminal point of the power supply to be replaced b Remove the button screws and any cable ties securing the power supply to be replaced Remove the power supply and bracket Tur...

Страница 6: ...ing the Omron 20 A AC DC power supply follow step 5 through step 13 5 Locate and remove the cables labeled PF F E L5 and N2 that were connected to PS2 as they are no longer needed 6 Locate and remove these cables brown cable labeled L4 that connects F 4 and K B terminal contact 4 brown cable labeled L5 that connects TB 2 and K B terminal contact 3 TB 2 K B F 4 ...

Страница 7: ...onnections remain the same If using the existing cables the connector heads have to be replaced with ferrule heads to connect to the Omron power supply If the existing cables are not long enough replace them with the new cables that have the same labels Be sure to connect the new cables to the same locations as the old cables 10 Locate the cable labeled F1 TB 1 to F 5 Disconnect the cable from TB ...

Страница 8: ...nline System E9988E 11 Connect a new cable labeled from F 5 to TB 1 12 Connect a new cable labeled L4 from F 4 to TB 2 13 At TB 1 connect a new cable labeled as shown below Continue with Completing the installation TB 1 F 5 TB 2 F 4 TB 1 ...

Страница 9: ...DC power supply 15 Connect the cables labeled ST ST E N1 L7 formerly from PS3 to the Cosel power supply Tighten the screws to secure the cables and close the protective cover Completing the installation 16 Make sure all the cables are routed properly in the trunking then close all the trunking covers 17 Ensure all connections are correct before securing the system s top cover Cosel 6 4 A AC DC pow...

Страница 10: ...E9988EL 1 Remove the button screws securing the system s top cover and remove the top cover 2 Remove the cap screws to remove the cover to the electrical panel 3 Remove the trunking covers to access the cables Turn off the main switch before beginning any replacement work electrical panel ...

Страница 11: ...n 20 A AC DC power supply remove PS1 and PS2 If installing the Cosel 6 4 A AC DC power supply remove PS3 a Open the protective cover and loosen the screws to release all cables at the AC DC power supply terminal point of the power supply to be replaced b Remove the button screws and any cable ties securing the power supply to be replaced Remove the power supply and bracket F 3 protective cover PS1...

Страница 12: ...ep 6 through step 15 6 Locate and remove the cables labeled PF F E L5 and N2 that were connected to PS2 as they are no longer needed 7 Locate and remove these cables cable labeled F that connects K 2 terminal contact 12 and TB 4 brown cable labeled L4 that connects K B terminal contact 12 and F 4 brown cable labeled L5 that connects K B terminal contact 8 and TB 2 ...

Страница 13: ...n power supply The terminal point connections remain the same If using the existing cables the connector heads have to be replaced with ferrule heads to connect to the Omron power supply If the existing cables are not long enough replace them with the new cables that have the same labels Be sure to connect the new cables to the same locations as the old cables 11 Connect a new cable labeled from F...

Страница 14: ...8EL 12 Connect a new cable labeled from K 2 terminal contact 12 to TB 4 13 Disconnect the blue cable labeled F1 from TB 3 and connect it to K B terminal contact 8 14 Connect a new cable labeled F2 from K B terminal contact 12 to TB 3 TB 4 K 2 TB 3 K B TB 3 K B ...

Страница 15: ...er supply If installing the Cosel 6 4 A AC DC power supply follow step 16 through step 20 16 Install the bracket and mount the new Cosel 6 4 A AC DC power supply 17 Connect the cables labeled ST ST E N1 and L7 formerly from PS3 to the Cosel power supply Tighten the screws to secure the cables and close the protective cover TB 2 F 4 Cosel 6 4 A AC DC power supply with bracket protective cover ...

Страница 16: ...9988EL Completing the installation 18 Make sure all the cables are routed properly in the trunking then close all the trunking covers 19 Ensure all connections are correct before securing the electrical panel cover 20 Close and secure the system s top cover ...

Страница 17: ...utton screws securing the system s top cover at the electrical panel side then remove the top cover 2 Remove the trunking covers to access the cables 3 Open the F 3 fuse holder and replace the 2 5 A slow blow fuse with a new 6 0 A slow blow fuse Turn off the main switch before beginning any replacement work F 3 ...

Страница 18: ...d b Remove the button screws and any cable ties securing the power supply to be replaced Remove the power supply and bracket Installing the Omron 20 A AC DC power supply If installing the Omron 20 A AC DC power supply follow step 5 through step 14 5 Locate and remove the cables labeled PF F E L5 and N2 that were connected to PS2 as they are no longer needed 6 Mount the bracket for the new Omron 20...

Страница 19: ... the connector heads have to be replaced with ferrule heads to connect to the Omron power supply If the existing cables are not long enough replace them with the new cables that have the same labels Be sure to connect the new cables to the same locations as the old cables 9 Connect a new cable labeled from F 5 to TB 3 10 Remove the cables labeled L4 and L5 which are connected between K B and TB 1 ...

Страница 20: ...2 to F 5 Disconnect the cable from TB 2 and connect it to K B 12 Connect a new cable labeled F2 to K B Connect the other end to TB 2 in the space previously occupied by F1 13 At TB 1 move the cable labeled L4 to the space previously occupied by L5 which was removed in step 5 TB 2 K B TB 2 K B TB 1 ...

Страница 21: ... AC DC power supply If installing the Cosel 6 4 A AC DC power supply follow step 15 through step 18 15 Install the bracket and mount the new Cosel 6 4 A AC DC power supply 16 Connect the cables labeled ST ST E N1 L7 formerly from PS3 to the Cosel power supply Tighten the screws to secure the cables and close the protective cover TB 2 Cosel 6 4 A AC DC power supply with bracket protective cover ...

Страница 22: ...070 4 mod Inline System E9986E Completing the installation 17 Make sure all the cables are routed properly in the trunking then close all the trunking covers 18 Ensure all connections are correct before securing the system s top cover ...

Страница 23: ......

Страница 24: ...This information is subject to change without notice 2020 Keysight Technologies Edition 2 May 2020 www keysight com ...