Keysight Technologies E5053A Скачать руководство пользователя страница 2

Notices

© 

Keysight Technologies

 

2005-2019

No part of this manual may be 

reproduced in any form or by any 

means (including electronic storage 

and retrieval or translation into a 

foreign language) without prior 

agreement and written consent from 

Keysight Technologies, Inc. as 

governed by United States and 

international copyright laws.

Trademark Acknowledgments
Manual Part Number

E5053-90020

Edition

Edition 4, April 2019

Printed in Malaysia

Published by:

Keysight Technologies International 
Japan G.K,

1-3-3 Higashikawasaki-cho

Chuo-ku 

Kobe-shi, Hyogo, Japan

Warranty

THE MATERIAL CONTAINED IN THIS 

DOCUMENT IS PROVIDED “AS IS,” 

AND IS SUBJECT TO BEING 

CHANGED, WITHOUT NOTICE, IN 

FUTURE EDITIONS. FURTHER, TO 

THE MAXIMUM EXTENT PERMITTED 

BY APPLICABLE LAW, KEYSIGHT 

DISCLAIMS ALL WARRANTIES, 

EITHER EXPRESS OR IMPLIED WITH 

REGARD TO THIS MANUAL AND 

ANY INFORMATION CONTAINED 

HEREIN, INCLUDING BUT NOT 

LIMITED TO THE IMPLIED 

WARRANTIES OF 

MERCHANTABILITY AND FITNESS 

FOR A PARTICULAR PURPOSE. 

KEYSIGHT SHALL NOT BE LIABLE 

FOR ERRORS OR FOR INCIDENTAL 

OR CONSEQUENTIAL DAMAGES IN 

CONNECTION WITH THE 

FURNISHING, USE, OR 

PERFORMANCE OF THIS 

DOCUMENT OR ANY INFORMATION 

CONTAINED HEREIN. SHOULD 

KEYSIGHT AND THE USER HAVE A 

SEPARATE WRITTEN AGREEMENT 

WITH WARRANTY TERMS 

COVERING THE MATERIAL IN THIS 

DOCUMENT THAT CONFLICT WITH 

THESE TERMS, THE WARRANTY 

TERMS IN THE SEPARATE 

AGREEMENT WILL CONTROL.

Technology Licenses

The hardware and/or software 

described in this document are 

furnished under a license and may be 

used or copied only in accordance 

with the terms of such license.

Declaration of Conformity

Declarations of Conformity for this 
product and for other Keysight 

products may be downloaded from 

the Web. Go to 

http://www.keysight.com/go/confor

mity

. You can then search by product 

number to find the latest Declaration 
of Conformity.

U.S. Government Rights

The Software is “commercial 
computer software,” as defined by 

Federal Acquisition Regulation 

(“FAR”) 2.101. Pursuant to FAR 

12.212 and 27.405-3 and 

Department of Defense FAR 

Supplement (“DFARS”) 227.7202, the 

U.S. government acquires 

commercial computer software 

under the same terms by which the 

software is customarily provided to 

the public. Accordingly, Keysight 

provides the Software to U.S. 

government customers under its 

standard commercial license, which 

is embodied in its End User License 

Agreement (EULA), a copy of which 

can be found at 

http://www.keysight.com/find/sweu

la

The license set forth in the EULA 

represents the exclusive authority by 

which the U.S. government may use, 

modify, distribute, or disclose the 

Software. The EULA and the license 

set forth therein, does not require or 

permit, among other things, that 

Keysight: (1) Furnish technical 

information related to commercial 

computer software or commercial 

computer software documentation 

that is not customarily provided to 

the public; or (2) Relinquish to, or 

otherwise provide, the  government 

rights in excess of these rights 

customarily provided to the public to 

use, modify, reproduce, release, 

perform, display, or disclose 

commercial computer software or 

commercial computer software 

documentation. No additional 

government requirements beyond 

those set forth in the EULA shall 

apply, except to the extent that those 

terms, rights, or licenses are 

explicitly required from all providers 

of commercial computer software 

pursuant to the FAR and the DFARS 

and are set forth specifically in 

writing elsewhere in the EULA. 

Keysight shall be under no obligation 

to update, revise or otherwise modify 

the Software.  With respect to any 

technical data as defined by FAR 

2.101, pursuant to FAR 12.211 and 

27.404.2 and DFARS 227.7102, the 

U.S. government acquires no greater 

than Limited Rights as defined in FAR 

27.401 or DFAR 227.7103-5 (c), as 
applicable in any technical data.

Safety Notices

CAUTION

 notice denotes a hazard. It 

calls attention to an operating 

procedure, practice, or the like that, 

if not correctly performed or adhered 

to, could result in damage to the 

product or loss of important data. Do 

not proceed beyond a CAUTION 

notice until the indicated conditions 

are fully understood and met. 

WARNING

 notice denotes a hazard. 

It calls attention to an operating 

procedure, practice, or the like that, 

if not correctly performed or adhered 

to, could result in personal injury or 

death. Do not proceed beyond a 

WARNING notice until the indicated 

conditions are fully understood and 
met.

Содержание E5053A

Страница 1: ...User s Guide Keysight E5053A Microwave Downconverter...

Страница 2: ...uter software under the same terms by which the software is customarily provided to the public Accordingly Keysight provides the Software to U S government customers under its standard commercial lice...

Страница 3: ...appropriate for the instrument being used refer to your instrument s Function Reference Electrostatic discharge ESD can damage the highly sensitive microcircuits in your instrument ESD damage is most...

Страница 4: ...ent unless another person capable of rendering first aid and resuscitation is present Do NOT Substitute Parts or Modify the Instrument To avoid the danger of introducing additional hazards do not inst...

Страница 5: ...facilities of other International Standards Organization members Exclusive Remedies The remedies provided herein are Buyer s sole and exclusive remedies Keysight Technologies shall not be liable for a...

Страница 6: ...Keysight E5053A Microwave Downconverter Caution Safety Symbols For any assistance contact your nearest Keysight Technologies Sales and Service Office Addresses are provided at the back of this manual...

Страница 7: ...t 15 Mounting handle kit Option 1CN 16 Mounting rackmount kit Option 1CM 17 Mounting rackmount handle kit Option 1CP 17 Power supply and fuse 18 Checking the power supply 18 Setting up the fuse 18 Che...

Страница 8: ...rconnection Ports and Test Ports 31 Cleaning a Display Other than Interconnection Ports and Test Ports 31 Cautions Applicable to Requesting Repair Replacement Regular Calibration etc 32 Devices to be...

Страница 9: ...ny of the following in the inspection contact you nearest Keysight Technologies sales office 1 If the shipping container or cushioning material is damaged or the cushioning material shows signs of unu...

Страница 10: ...1 Option o Manual Option ABA 3 User s Guide E5053 900x0 1 o Handle kit Option 1CN 4 5063 9227 1 o Rackmount kit Option 1CM 5 5063 9214 1 E5053 61623 2 E5053 61624 2 o Rackmount handle kit Option 1CP 5...

Страница 11: ...Keysight E5053A Microwave Downconverter 11 Installation Incoming inspection Figure 1 1 Accessories...

Страница 12: ...nvironmental conditions Temperature 10 C to 40 C Temperature range for error correction 23 C 5 C 1 C deviation from the temperature when performing the error correction Humidity 20 to 80 at wet bulb t...

Страница 13: ...rmation on ambient temperature to satisfy the specifications and measurement accuracy of the product refer to the Specifications and supplemental performance characteristics Chapter in the User s Guid...

Страница 14: ...ing space to disconnect the power cable s plug As described in Cutting power supply on page 20 the disconnecting device the device to cut the supply of power of the E5053A is the plug of the power cab...

Страница 15: ...o move transport it Option 1CN and how to mount it into a rack as part of a measurement system Option 1CM without handles Option 1CP with handles Option Name Keysight part number 1CN Handle kit 5063 9...

Страница 16: ...low these steps to mount it referring to the Figure 1 4 Step 1 Remove the trim strips 1 stuck to both the sides of the front panel stuck to the frame Step 2 Mount the front handles 3 to both the sides...

Страница 17: ...on Step 4 Mount the E5053A into the rack Mounting rackmount handle kit Option 1CP The rackmount handle kit is a kit that contains both the flanges for rackmount and the front handles for the E5053A Fo...

Страница 18: ...t meets the following specifications UL CSA type Slo Blo 5x20 mm miniature fuse 3A 250V Keysight part number 2110 1017 Spare fuses are available from Keysight Technologies sales offices To check or re...

Страница 19: ...from shock hazards Step 1 Check the power cable you use for damage Step 2 Connect the attached power cable between the power cable receptacle on the rear panel of the E5053A see Figure 1 5 on page 18...

Страница 20: ...at the switch pushed in is pulled up Cutting power supply For the E5053A the disconnecting device the device to cut the power supply is the power cable s plug on the power outlet side or the E5053A si...

Страница 21: ...of Product This chapter presents an overview of the E5053A microwave downconverter About This Product The Keysight E5053A is a microwave downconverter associated with the E5052B signal source analyzer...

Страница 22: ...hannel 2 input output port When using an external mixer disconnect this port 3 IF LO channel 1 input output port When using an external mixer disconnect this port 4 RF channel 2 input output port Conn...

Страница 23: ...1010 1 Do not apply a DC voltage greater than 0 V to the connection port In particular there is the risk of the capacitor remaining charged Connect the measurement sample DUT after the analyzer has be...

Страница 24: ...cts female 2 External reference signal input connector channel 1 channel 2 Ref In A reference signal input connector in order to phase lock the E5053A measurement signal with an external frequency ref...

Страница 25: ...onnector for outputting the internal frequency reference signal from the E5053A By connecting this output connector to the external reference signal input connector of another device the device can be...

Страница 26: ...26 Keysight E5053A Microwave Downconverter Overview of Product Names and Functions of Parts 2...

Страница 27: ...5053A Microwave Downconverter User s Guide 3 Connecting Devices to E5052B for Operation This chapter describes how to connect the E5052B signal source analyzer and the E5053A microwave downconverter f...

Страница 28: ...cable supplied with the E5053A Keysight part number E5053 61621 E5053 61622 USB cable supplied with the E5053A Keysight part number 8121 0770 BNC m BNC m cable 61 cm supplied with the E5053A Keysight...

Страница 29: ...el As shown in Figure 3 2 connect the E5052B and the rear panel of the E5053A with the USB cable BNC cable and BNC adapter Figure 3 2 Connecting E5052B and E5053A Rear Panel Do not connect disconnect...

Страница 30: ...the Measurement Using the E5053A and a External Mixer chapter in the E5052B Signal Source Analyzer User s Guide If the E5052B is turned on first the E5053A cannot be recognized and the downconverter...

Страница 31: ...onnectors free from stains and dust Do not touch the contact surface on the connectors Do not plug damaged or scratched connectors into the test ports Use compressed air for cleaning connectors Do not...

Страница 32: ...calibration of the unit by our Service Center send only the E5053A main unit without any installed option you may have ordered Unless specifically instructed it is not necessary to send accessories a...

Страница 33: ...ier than the current printing date of this manual Manual Changes To adapt this manual to your E5053A refer to Table A 1 Keysight Technologies uses a two part ten character serial number that is stampe...

Страница 34: ...34 Keysight E5053A User s Guide Manual Changes Manual Changes...

Страница 35: ...tion incoming inspection 9 Interconnection Ports Maintenance 31 Internal Reference Signal Output Connector 25 M manual changes 33 N names and functions of parts 22 O operating environment 12 P power s...

Страница 36: ...Keysight E5053A User s Guide Index 36...

Страница 37: ...This information is subject to change without notice Keysight Technologies 2005 2019 Edition 4 April 2019 E5053 90020 E5053 90020 www keysight com...

Отзывы: