DDR2(+LP) Compliance Testing Methods of Implementation
199
Clock Timing (CT) Tests
14
Measurement Algorithm
1 Acquire and split read and write burst of the acquired signal.
2 Take the first valid READ burst found.
3 Find all DQS middle cross points at V
REF
in the burst.
4 Find all Clock middle cross points at V
REF
in the burst.
5 Find the first DQS rising edge in the READ burst by searching for the earliest rising cross point
among all the DQS middle cross points. Take the first DQS rising edge as the tDQSCK strobe
point.
6 Find the closest Clock-DQS (the Clock rising middle crossing point that is closest to the first DQS
rising edge).
7 Find the tDQSCK clock point. It is the Clock middle crossing point right before the closest
Clock-DQS at tDQSCK Delay (cycle). By default, tDQSCK Delay is one cycle. For example, if
tDQSCK Delay = 1, then the tDQSCK clock point is the Clock middle crossing point right before
the closest Clock-DQS. If tDQSCK Delay = 3, then the tDQSCK clock point is the Clock middle
crossing point three clock cycles before the closest Clock-DQS. tDQSCK Delay is configurable in
the configuration page.
8 Compare the tDQSCK strobe point to the tDQSCK clock point as the test result. Mathematically,
test result = tDQSCK strobe point - tDQSCK clock point.
9 Display the test result by going to the measurement location on the waveform and locate the
marker to tDQSCK strobe point and tDQSCK clock point.
10 Compare the test result against the compliance test limit.
Содержание D9020DDRC
Страница 1: ...Keysight D9020DDRC DDR2 LP Compliance Test Application Methods of Implementation ...
Страница 10: ...10 DDR2 LP Compliance Testing Methods of Implementation ...
Страница 40: ...1 Installing the DDR2 Compliance Test Application 40 DDR2 LP Compliance Testing Methods of Implementation ...
Страница 46: ...2 Preparing to Take Measurements 30 DDR2 LP Compliance Testing Methods of Implementation ...
Страница 70: ...3 Measurement Clock Tests 54 DDR2 LP Compliance Testing Methods of Implementation ...
Страница 134: ...6 Single Ended Signals VIH VIL Data Mask Tests 118 DDR2 LP Compliance Testing Methods of Implementation ...
Страница 158: ...9 Single Ended Signals Overshoot Undershoot Tests 142 DDR2 LP Compliance Testing Methods of Implementation ...
Страница 186: ...10 Differential Signals AC Input Parameters Tests 170 DDR2 LP Compliance Testing Methods of Implementation ...
Страница 224: ...14 Clock Timing CT Tests 208 DDR2 LP Compliance Testing Methods of Implementation ...
Страница 270: ...15 Data Strobe Timing DST Tests 254 DDR2 LP Compliance Testing Methods of Implementation ...
Страница 342: ...17 Command and Address Timing CAT Tests 326 DDR2 LP Compliance Testing Methods of Implementation ...
Страница 366: ...19 Calibrating the Infiniium Oscilloscope and Probe 350 DDR2 LP Compliance Testing Methods of Implementation ...