11
Differential Signal AC Output Parameters Tests
174
DDR2(+LP) Compliance Testing Methods of Implementation
V
OX ,
AC Differential Output Cross Point Voltage - Test Method of Implementation
The purpose of this test is to verify the crossing point of the output differential test signals pair is
within the conformance limits of the V
OX(AC)
as specified in the JEDEC specification.
The value of V
DDQ
which directly affects the conformance lower limit is set to 1.8V. User may choose
to use the UDL (User Defined Limit) feature in the application to perform this test against a
customized test limit set based on the different values of V
DDQ
.
Signals of Interest
Mode Supported: DDR2 only
Signal cycle of interest: READ
Signal(s) of Interest:
• Data Strobe Signal (supported by Data Signal)
Signals required to perform the test on the oscilloscope:
• Pin Under Test, PUT - any signal of interest, as defined above
• Supporting Pin - a corresponding DQ signal
Test Definition Notes from the Specification
Table 107
Differential AC Output Parameters
Symbol
Parameter
Min
Max
Units
Notes
V
OX(AC)
AC differential cross point voltage
0.5 * V
DDQ
- 0.125
0.5 * V
DDQ
+ 0.125
V
1
Table 108
Differential AC Output Parameters (DDR2-1066)
Symbol
Parameter
Min
Max
Units
Notes
V
OX(AC)
AC differential cross point voltage
0.5 * V
DDQ
- 0.125
0.5 * V
DDQ
+ 0.125
V
1
Содержание D9020DDRC
Страница 1: ...Keysight D9020DDRC DDR2 LP Compliance Test Application Methods of Implementation ...
Страница 10: ...10 DDR2 LP Compliance Testing Methods of Implementation ...
Страница 40: ...1 Installing the DDR2 Compliance Test Application 40 DDR2 LP Compliance Testing Methods of Implementation ...
Страница 46: ...2 Preparing to Take Measurements 30 DDR2 LP Compliance Testing Methods of Implementation ...
Страница 70: ...3 Measurement Clock Tests 54 DDR2 LP Compliance Testing Methods of Implementation ...
Страница 134: ...6 Single Ended Signals VIH VIL Data Mask Tests 118 DDR2 LP Compliance Testing Methods of Implementation ...
Страница 158: ...9 Single Ended Signals Overshoot Undershoot Tests 142 DDR2 LP Compliance Testing Methods of Implementation ...
Страница 186: ...10 Differential Signals AC Input Parameters Tests 170 DDR2 LP Compliance Testing Methods of Implementation ...
Страница 224: ...14 Clock Timing CT Tests 208 DDR2 LP Compliance Testing Methods of Implementation ...
Страница 270: ...15 Data Strobe Timing DST Tests 254 DDR2 LP Compliance Testing Methods of Implementation ...
Страница 342: ...17 Command and Address Timing CAT Tests 326 DDR2 LP Compliance Testing Methods of Implementation ...
Страница 366: ...19 Calibrating the Infiniium Oscilloscope and Probe 350 DDR2 LP Compliance Testing Methods of Implementation ...