background image

PRODUCT MARKINGS:

This symbol indicates the instrument is 
sensitive to electrostatic discharge (ESD). 
ESD can damage the highly sensitive 
components in your instrument. ESD 
damage is most likely to occur as the 
module is being installed or when cables 
are connected or disconnected. Protect 
the circuits from ESD damage by wear-
ing a grounding strap that provides a high 
resistance path to ground. Alternatively, 
ground yourself to discharge any built-
up static charge by touching the outer 
shell of any grounded instrument chassis 
before touching the port connectors.

The CE mark is a registered trademark of 
the European Community.

This symbol indicates product compliance 
with the Canadian Interference-Causing 
Equipment Standard (ICES-001). It also 
identifies the product is an Industrial 
Scientific and Medical Group 1 Class A 
product (CISPR 11, Clause 4).

To prevent electrical shock, disconnect 
the Keysight Technologies instrument from 
mains before cleaning. Use a dry cloth or 
one slightly dampened with water to clean 
the external case parts. Do not attempt to 
clean internally. To clean the connectors, 
use alcohol in a well-ventilated area. Allow 
all residual alcohol moisture to evaporate, 
and the fumes to dissipate prior to energiz-
ing the instrument.

This symbol represents the South Korean 
Class A EMC Declaration.  This equipment 
is Class A suitable for professional use and 
is for use in electromagnetic environments 
outside of the home.

Australian Communication and Media 
Authority mark to indicate regulatory com-
pliance as a registered supplier.

This symbol indicates the time period dur-
ing which no hazardous or toxic substance 
elements are expected to leak or deterio-
rate during normal use. Forty years is the 
expected useful life of the product.

This symbol on an instrument means 
caution risk of danger. You should refer to 
the operating instructions located in the 
user documentation in all cases where the 
symbol is marked on the instrument.

This symbol indicates separate collection 
for electrical and electronic equipment, 
mandated under EU law as of August 13, 
2005. All electric and electronic equipment 
are required to be separated from normal 
waste for disposal (Reference WEEE Direc-
tive, 2002/96/EC).

No operator serviceable parts inside. Refer 
servicing to qualified personnel. To prevent 
electrical shock do not remove covers. For 
continued protection against fire hazard, 
replace fuse with same type and rating.

WARNING

CLEANING PRECAUTIONS:

WARNING

A 급 기기 ( 업무용 방송통신기자재 ) 
이 기기는 업무용 (A 급 ) 전자파적합
기기로서 판 매자 또는 사용자는 이 점
을 주 의하시기 바라 며 , 가정외의 지역
에서 사용하는 것을 목적으 로 합니다.

Содержание 90015

Страница 1: ...Keysight Technologies M9391A PXIe Vector Signal Analyzer 1 MHz to 3 or 6 GHz Specifications Guide...

Страница 2: ...U S government may use modify distribute or disclose the Software This EULA and the license set forth herein does not require or permit among other things that Keysight 1 Fur nish technical informati...

Страница 3: ...st leads and jumpers for possible wear cracks or breaks before each use When installing equipment where access to the main power cord is restricted such as rack mounting a separate main input power di...

Страница 4: ...area Allow all residual alcohol moisture to evaporate and the fumes to dissipate prior to energiz ing the instrument This symbol represents the South Korean Class A EMC Declaration This equipment is...

Страница 5: ...technical specifications for all versions of the M9391A PXIe Vector Signal Analyzer Specifications published in the datasheet only apply to the current manufactur ing version of the equipment If a spe...

Страница 6: ...ated within the controlled temperature range Recommended best practices in use Use slot blockers and EMC filler panels in empty module slots to ensure proper operating temperatures Keysight chassis an...

Страница 7: ...nal can be digitized for further analysis or processing in the time frequency or modulation domain 2 When used with the M9018A PXIe chassis 2 link configuration 1 x 8 factory default and M9036A PXIe e...

Страница 8: ...ernal time base or external reference input Internal timebase Accuracy time since last adjustment x aging rate temperature effects calibration accuracy Frequency stability Aging rate Daily 0 5 ppb day...

Страница 9: ...solute amplitude accuracy is the total of all amplitude measurement errors This specification includes the sum of the following individual specifica tions linearity expected input level switching unce...

Страница 10: ...nal IF flatness 14 15 Analysis bandwidth IF filter Nominal 40 MHz 40 MHz 0 08 dB 100 MHz 160 MHz 0 09 dB 160 MHz 160 MHz 0 10 dB IF phase linearity 15 Analysis bandwidth Conversion type Peak to peak n...

Страница 11: ...0 64 dB 0 27 dB 0 21 dB Pre amp AUTO Crossing 37 dBm 0 95 dB 0 19 dB 0 12 dB Amplitude switching speed Arbitrary amplitude change Standard nominal Option UNZ nominal List mode switching speed 17 5 ms...

Страница 12: ...1 to 3 6 GHz 154 dBm Hz 158 dBm Hz 3 6 to 5 GHz 151 dBm Hz 156 dBm Hz 5 to 6 GHz 146 dBm Hz 153 dBm Hz Third order intermodulation distortion TOI 20 TOI23 Distortion24 Conversion type auto Frequency...

Страница 13: ...rs with 60MHz tone spacing for 3rd order intermodulation measurements 150 140 130 120 110 100 90 80 70 60 50 45 40 35 30 25 20 15 10 Nominal Dynamic Range at 5 8 GHz Pre Amp O Single High 3rd Order In...

Страница 14: ...3rd order intermodulation measurements 150 140 130 120 110 100 90 80 70 60 50 40 35 30 25 20 15 10 5 Nominal Dynamic Range at 2 GHz Pre Amp O Image Protect 3rd Order Intermodulation DANL 1Hz RBW DANL...

Страница 15: ...0 1000 10000 Phase Noise dBc Hz O set kHz Nominal Phase Noise at 1 GHz Image Protect Single Low Single High 150 140 130 120 110 100 90 80 0 1 1 10 100 1000 10000 Phase Noise dBc Hz O set kHz Nominal P...

Страница 16: ...Image responses 35 Conversion type Frequency Nominal Image protect All 68 dBc IF rejection 36 IF bandwidth filter Frequency Nominal 15 MHz 400 MHz 57 dBc 400 MHz 105 dBc 40 MHz 450 MHz 57 dBc 450 MHz...

Страница 17: ...apture IDs In particular the memory for the default single acquisition is allocated from the area unused by the list acquisitions If the available memory is not sufficient for the single acquisition t...

Страница 18: ...set 73 dBc 800 kHz offset 77 dBc 1200 kHz offset 80 dBc 1800 kHz offset 78 dBc EDGE 49 50 Parameters Nominal Residual EVM 0 9 1 8 1 9 2 0 2 1 2 2 GHz 0 23 rms ORFS dynamic range 200 kHz offset 37 dBc...

Страница 19: ...5 8 GHz 80 MHz BW 46 5 dB 44 3 dB 43 0 dB 43 6 dB 5 8 GHz 160 MHz BW 44 7 dB 43 4 dB 41 7 dB 43 3 dB Preamble pilots data EVM 55 5 8 GHz 80 MHz BW 49 4 dB 48 6 dB 47 3 dB 46 4 dB 5 8 GHz 160 MHz BW 4...

Страница 20: ...Hz bandwidth Figure 8 WLAN 802 11a g SEM at 2 4 GHz 20 MHz bandwidth Figure 9 WLAN 802 11a g SEM at 5 5 GHz 20 MHz bandwidth 60 50 40 30 20 10 0 Spectral Emissions Limit 70 60 50 40 30 20 10 0 Amplitu...

Страница 21: ...xing 0 9 GHz 49 8 dB 0 32 50 1 dB 0 31 2 0 GHz 49 2 dB 0 35 49 3 dB 0 34 LTE TDD MIMO 58 59 60 Parameters 2 channel nominal 4 channel nominal 10 MHz BW EVM R9 downlink 64 QAM open loop spacial multipl...

Страница 22: ...MB 001 This ISM device complies with Canadian ICES 001 Cet appareil ISM est conforme a la norme NMB 001 du Canada Warm up time 45 minutes Size M9300A M9301A M9350A M9214A 1 PXIe slot 1 PXIe slot 1 PXI...

Страница 23: ...rosoft NET Framework 3 5 SP1 67 100 MB for Keysight IO Libraries Suite Video Support for DirectX 9 graphics with 128 MB graph ics memory recommended Super VGA graphics is supported Browser Microsoft I...

Страница 24: ...89 Hong Kong 800 938 693 India 1 800 11 2626 Japan 0120 421 345 Korea 080 769 0800 Malaysia 1 800 888 848 Singapore 1 800 375 8100 Taiwan 0800 047 866 Other AP Countries 65 6375 8100 Europe Middle Eas...

Отзывы: