background image

Notices

© Keysight Technologies, Inc. 

1989–2021

No part of this manual may be 

reproduced in any form or by any 

means (including electronic storage 

and retrieval or translation into a 

foreign language) without prior 

agreement and written consent from 

Keysight Technologies, Inc. as 

governed by United States and 

international copyright laws.

Trademark Acknowledgments

Manual Part Number

11612-90001

Edition

Edition 1, August 2021

 

Supersedes: January 2015

Printed in USA/Malaysia

Published by:

Keysight Technologies

1400 Fountaingrove Parkway 

Santa Rosa, CA 95403

Warranty

THE MATERIAL CONTAINED IN THIS 

DOCUMENT IS PROVIDED “AS IS,” 

AND IS SUBJECT TO BEING 

CHANGED, WITHOUT NOTICE, IN 

FUTURE EDITIONS. FURTHER, TO 

THE MAXIMUM EXTENT PERMITTED 

BY APPLICABLE LAW, KEYSIGHT 

DISCLAIMS ALL WARRANTIES, 

EITHER EXPRESS OR IMPLIED WITH 

REGARD TO THIS MANUAL AND 

ANY INFORMATION CONTAINED 

HEREIN, INCLUDING BUT NOT 

LIMITED TO THE IMPLIED 

WARRANTIES OF 

MERCHANTABILITY AND FITNESS 

FOR A PARTICULAR PURPOSE. 

KEYSIGHT SHALL NOT BE LIABLE 

FOR ERRORS OR FOR INCIDENTAL 

OR CONSEQUENTIAL DAMAGES IN 

CONNECTION WITH THE 

FURNISHING, USE, OR 

PERFORMANCE OF THIS 

DOCUMENT OR ANY INFORMATION 

CONTAINED HEREIN. SHOULD 

KEYSIGHT AND THE USER HAVE A 

SEPARATE WRITTEN AGREEMENT 

WITH WARRANTY TERMS 

COVERING THE MATERIAL IN THIS 

DOCUMENT THAT CONFLICT WITH 

THESE TERMS, THE WARRANTY 

TERMS IN THE SEPARATE 

AGREEMENT WILL CONTROL.

Technology Licenses

The hardware and/or software 

described in this document are 

furnished under a license and may be 

used or copied only in accordance 

with the terms of such license.

U.S. Government Rights

The Software is “commercial 

computer software,” as defined 

by Federal Acquisition Regulation 

(“FAR”) 2.101. Pursuant to FAR 

12.212 and 27.405-3 and 

Department of Defense FAR 

Supplement (“DFARS”) 227.7202, 

the U.S. government acquires 

commercial computer software 

under the same terms by which 

the software is customarily 

provided to the public. 

Accordingly, Keysight provides 

the Software to U.S. government 

customers under its standard 

commercial license, which is 

embodied in its End User License 

Agreement (EULA), a copy of 

which can be found at 

http://www.keysight.com/find/sweula

The license set forth in the EULA 

represents the exclusive authority 

by which the U.S. government 

may use, modify, distribute, or 

disclose the Software. The EULA 

and the license set forth therein, 

does not require or permit, 

among other things, that 

Keysight: (1) Furnish technical 

information related to 

commercial computer software 

or commercial computer 

software documentation that is 

not customarily provided to the 

public; or (2) Relinquish to, or 

otherwise provide, the 

government rights in excess of 

these rights customarily provided 

to the public to use, modify, 

reproduce, release, perform, 

display, or disclose commercial 

computer software or 

commercial computer software 

documentation. No additional 

government requirements 

beyond those set forth in the 

EULA shall apply, except to the 

extent that those terms, rights, or 

licenses are explicitly required 

from all providers of commercial 

computer software pursuant to 

the FAR and the DFARS and are 

set forth specifically in writing 

elsewhere in the EULA. Keysight 

shall be under no obligation to 

update, revise or otherwise 

modify the Software. With 

respect to any technical data as 

defined by FAR 2.101, pursuant 

to FAR 12.211 and 27.404.2 and 

DFARS 227.7102, the U.S. 

government acquires no greater 

than Limited Rights as defined in 

FAR 27.401 or DFAR 227.7103-5 

(c), as applicable in any technical 

data.

Safety Notices

CAUTION

 notice denotes a hazard. It 

calls attention to an operating 

procedure, practice, or the like that, 

if not correctly performed or adhered 

to, could result in damage to the 

product or loss of important data. Do 

not proceed beyond a CAUTION 

notice until the indicated conditions 

are fully understood and met. 

WARNING

 notice denotes a hazard. 

It calls attention to an operating 

procedure, practice, or the like that, 

if not correctly performed or adhered 

to, could result in personal injury or 

death. Do not proceed beyond a 

WARNING notice until the indicated 

conditions are fully understood and 
met.

Содержание 11612A

Страница 1: ...Operating and Service Manual Includes Option 001 Serial Numbers This manual applies directly to Keysight 11612A Bias Networks with serial number prefix 2301A and higher Keysight 11612A Bias Network...

Страница 2: ...Software to U S government customers under its standard commercial license which is embodied in its End User License Agreement EULA a copy of which can be found at http www keysight com find sweula Th...

Страница 3: ...1 Keysight Technologies 11612A Bias Network Operation and Service Manual 11612A Bias Network Figure 1 11612A Dimensions In the following graphic all dimensions are in millimeters...

Страница 4: ...contents of this manual apply to bias networks having a serial number equal to or higher than the serial number listed on the title page of this manual Incoming Inspection If the bias network or its...

Страница 5: ...GHz 14 dB 1 to 18 GHz 18 dB 18 to 26 5 GHz 14 dB Insertion Loss Maximum 0 4 to 12 4 GHz 1 0 dB 12 4 to 26 5 GHz 1 5 dB Maximum Bias Current 2 amps dc up to 32 amps in pulsed mode Refer to Figure 5 on...

Страница 6: ...lb Dimensions nominal not including connectors 30 mm x 33 mm x 25 mm 1 2 in x 1 3 in x 1 0 in a The electrical performance of the bias network is independent of its pin depth within the range stated...

Страница 7: ...capacitance acts as a low pass filter Bias Network Schematic Diagram Figure 3 shows the 11612A bias network connected in a typical measurement setup Although other applications are possible the gener...

Страница 8: ...k so the correct bias level and repetition rate can be set before the bias network is connected Transistors and negative resistance devices may oscillate if the bias port of the 11612A bias network is...

Страница 9: ...and repetition rate are within the allowed limits remove the resistor and insert the bias network Storage and Shipment Store and ship the bias network within the following limits Returning a Device t...

Страница 10: ...for a standard reflection measurement 2 Calibrate the system with an open and a short 3 Connect the appropriate RF port of the 11612A to the network analyzer test port Terminate the opposite port with...

Страница 11: ...nput Port Input Port 0 045 to 8 GHz 0 4 to 1 GHz 8 to 18 GHz 1 to 18 GHz 18 to 26 5 GHz 18 to 26 5 GHz Output Port Output Port 0 045 to 8 GHz 0 4 to 1 GHz 8 to 18 GHz 1 to 18 GHz 18 to 26 5 GHz 18 to...

Страница 12: ...10 Operation and Service Manual 11612 90001 11612A Bias Network Figure 5 11612A Option 001 Duty Cycle Curves Overall View...

Страница 13: ...measurement needs and information on finding a local Keysight office are available on the Web at www keysight com find assist In any correspondence or telephone conversation refer to the Keysight pro...

Страница 14: ...12 Operation and Service Manual 11612 90001 11612A Bias Network...

Страница 15: ...Installation Note Xxxxx xxxxx 3...

Страница 16: ...This information is subject to change without notice Keysight Technologies 1989 2021 Edition 1 August 2021 www keysight com...

Отзывы: