background image

12

Simple Troubleshooting

Situation 1

Situation 2

Situation 3

Situation 4

After the installation of the lockset and batteries, the door cannot
be locked and three short beeps are emitted when you press the
Programming button.

After the installation of the lockset and batteries, no responses
when you press any button (no sounds are emitted, and the back
light does not work).

Fail in the first execution of the door-handing indentifying process
(the red light flashes three times, and three short beeps are emitted).

Although succeeded in the first execution of the door-handing
indentifying process, the latch does not work.

(Feeling that the motor runs powerlessly, the latch bolt is stuck,

and the turn-piece inside cannot be rotated.)

Causes
Solutions

Causes

Solutions

Causes
Solutions

Causes
Solutions

: The door-handing indentifying process is not yet complete.

: Please execute the door-handing indentifying process as soon as the

installation of the lockset is completed.

: It could be a problem caused by the batteries or the improper connection of

the cable.

: Check to see if the battery polarities have been reversed or if the battery is

dead.  If so, please re-install or change the battery.  If not, please check if
the cable is appropriately connected.

: Wrong door-handing or change of the door-handing in the memory.

: Press the R button to restore the system to factory default setting and

re-execute door-handing indentifying process.

: Low battery.

: Please replace with new batteries.

11

Programming Code (PC)

USER Code (UC)

Enter PC

6

Set Autolock Time Delay

Enter Seconds

(10~99)

Remark : 10-99 seconds delay-time available.

Toggle Mute On/Off

Enter PC

7

Remark : Repeat same steps to turn beeper On/Off.

LED illumination is still functioning when it's in mute.
But there will be no any warning alarm.

Enable/Disable All User Code

Enter PC

8

Create a disposable User Code

Enter PC

9

Enter new

disposable

UC

Remark : Auto-locking and Keypad locking function will be invalid when User Codes

are disabled. The lock can only be operated by key during the time.
Repeat the steps to enable the User Codes again.

Restore all preset lock settings

Press

R

Remark : Press “R” button for over 5 seconds, the programming will complete after

you hear 3 long beeps.
After restore, you need to run the door handing identifying process before
other function setting.

Remark : Disposable code will be no longer valid once being used.

Содержание KP250

Страница 1: ...TE 45 40 35 1 3 4 1 9 16 1 3 8 Fit here on door edge FOR BACKSET 70mm 2 3 4 FOR BACKSET 60mm 2 3 8 51 2 Mark 1 25 4mm hole at center of door edge 54mm 2 1 8 Attention Please do not use the electronic...

Страница 2: ...a hole 2 1 8 54mm through the door face for the lockset then a hole of 1 25 4mm for latch 2 a Insert the latch and ensure it is paralleled to the door face Mark the outline of the faceplate then take...

Страница 3: ...m outside the door is left handed if the hinge is on the left hand side of the door whereas the door is right handed if the hinge is on the right hand side of the door Interior Exterior Door Hinge Lef...

Страница 4: ...LED flashes green twice when successful programming 3 3 LED flashes red 3 times when there is an operation error 3 4 LED flashes red 5 times when codes input error the operation will stop for system...

Страница 5: ...d by key or pressing User Code on keypad from outside or by interior turn piece 12 2 To unlock the door on the keypad enter the User Code and then press the Programming Enter button The door will be l...

Страница 6: ...ttery in order to stabilize the power supply 2 Do not mix alkaline battery with regular zinc carbon ones or mixed brands 3 Do not use any chemical liquid or lubricating oil with additives to clean the...

Страница 7: ...have been reversed or if the battery is dead If so please re install or change the battery If not please check if the cable is appropriately connected Wrong door handing or change of the door handing...

Страница 8: ...ection of latch bolt position is abnormal Please take out one battery first then press any button on the front panel for electric discharge and put the battery back next The latch bolt will automatica...

Страница 9: ...e remote is still valid and won t occupy the number of available remotes 3 Up to 5 remote controls available 2 Delete All Remotes 1 Enter Programming Code Press Press Press 2 It s not available to del...

Отзывы: