8
CALIBRATION
,
cont.
Run the Tracer Setup process a second time and compare the X & Y values of this
process with the previous set. The values should not change more than +/- 3.
EXAMPLE:
If during the first calibration process X= 0 and Y= -4.
In the second calibration process:
X must be between values -3 and +3
Y must be between values -7 and -1.
If the values are outside the +/- 3 variation run the calibration process a third time
and compare the second set of numbers to the third.
IMPORTANT
PRESS START
.
Press
TRACER ADJUSTMENT
.
REMOVE CALIBRATION TRACER
T00 from the cutter spindle.
PRESS OK