11
CALIBRATION
,
cont.
PRESS OK
.
PRESS SAVE
.
Run the calibration a second time and compare the X, Y & Z values with the first
set of numbers and make sure that they do not change more than +/- 3.
EXAMPLE:
If the first calibration values are X= -44, Y= -51 and Z= -28
In the second calibration values can be:
X must be between -47 and -41
Y must be between -54 and -48
Z must be between -31 and -25
If the values are outside the +/- 3 variation run the calibration process a third time
and compare the second set of numbers to the third.
IMPORTANT