SAUNA CONTROL CON3

1. Time indicator 2. Temperature display (or

display waiting time when in waiting mode)

3. Time indicator 4. Heat preserving indicator

5. Temperature and Time adjust button

6. Time setting button

7. ON/OFF

8. Fan

switch 9. Lamp switch 10. Heating indicator

Figure 1 Sauna control panel CON3

ON/OFF

Press “ON/OFF” button to turn on the control panel, system enters waiting

mode if applicable or heat-up mode depending on user's setting.

Press “ON/OFF” in waiting mode, system stops waiting and enters heat-up

mode immediately; Press “ON/OFF” in heat-up mode or heating-up time is up,
system switches off.

CHANGE TEMPERATURE UNIT

Press both “▲” and “▼” button for more than 3 seconds to switch between

temperature units, “

” and “

” appears on the screen by turns. Release both

button when the temperature unit you wish to choose appears, this will confirm
your choice. 3 seconds later, the temperature unit display disappears and screen
resume to display current temperature in the unit you have chosen.

CHANGE TEMPERATURE SETTING

Press “▲” or “▼” button to adjust temperature

the screen blinks and display

the previous setting temperature in the range of 158

194

℉(

70

90

℃)

. Press

“▲” to increase 2

℉(

1

℃)

or press “▼” to decrease 2

℉(

1

℃),

until you satisfied.

System will confirm your setting after 5 second no operation, and the screen
resumes displaying current temperature.

10

9

8

7

6

4

5

3

2

1

S A U N A  C O N T R O L

TIME

SET

3

C O N

OFF

ON

OFF

ON

Содержание CON3

Страница 1: ...CON3 140621...

Страница 2: ...off CHANGE TEMPERATURE UNIT Press both and button for more than 3 seconds to switch between temperature units and appears on the screen by turns Release both button when the temperature unit you wish...

Страница 3: ...mode Led screen displays the hour such as H10 and minute such as 45 information by turns If the wait time is less than 1 hour only minute information is displayed Once the waiting time is up system e...

Страница 4: ...e The yellow indicator turns on 6 Temperature sensor error If the sensor is not proper connected or not function well Led screen display SE CONNECTIONS OF THE SAUNA SYSTEM Please refer to figure 2 3 4...

Страница 5: ...trol Temp sensor Box Transform Light 40W High temp Switch Temperature sensor Relay Wiring Diagram CON3 Sauna Control System 3 9kW 240VAC 60Hz SAUNA CONTROL 12VAC Heating 12VDC Working TEMP SN JUMP N C...

Страница 6: ...1 2 3 6 4 5 Wiring Diagram 3 9kW 208 240V 3N 50 60Hz High temp Switch Temperature sensor CON3 Sauna Control System SAUNA CONTROL CON3 Control Fan 40W 120V 120V Light 40W 12VAC Heating 12VDC Working TE...

Страница 7: ...temp Switch Temperature sensor Mainboard Relay Wiring Diagram 10 5 25kW 240VAC 60Hz CON3 Sauna Control System SAUNA CONTROL CON3 Control Fan 40W 120V 120V Light 40W 12VAC Heating 12VDC Working TEMP S...

Страница 8: ...50 60Hz High temp Switch Temperature sensor Wiring Diagram 208 240V 3N 50 60Hz 10 5 25kW CON3 Sauna Control System SAUNA CONTROL CON3 Control Fan 40W 120V 120V Light 40W 12VAC Heating 12VDC Working TE...

Отзывы: