KEY RK-2006LSPz Скачать руководство пользователя страница 7

7

MINIMUM POWER OPERATION MODE.

When in this mode the controller operates fuel feeding and fan operation to

maintain firing to ensure the minimum fuel consumption. Fuel and air feeding rate is

adjusted by the technician. If in spite of boiler minimum power, increase temperature

follows of water temperature in relation to the top hysteresis parameter setting, the

controller will be switched into EXTINCTION(SHUT DOWN) mode. When the boiler

water temperature drops below the desired setting it will result in switching of the

controller into „max power operation mode”. Pressing STOP button, exceeding time

limit for cleaning, thermostat contacts opening or if water temperature in domestic

water tank is obtained during operation in MINIMUM POWER mode will result in

switching of the controller into EXTINCTION (SHUT DOWN) mode.

SCAVENGE (AIR PURGING).

During the operation with minimum power output, the controller will activate flue

scavenge (purging) to ensure removal of accumulated gases. Scavenge (purging) is

provided with temporary fan operation in higher speed.

EXTINCTION (SHUT DOWN).

When in this mode the controller turns off the fuel auger and engages the fan to

ensure complete fuel combustion and the burner cool down. Fan power when in

EXTINCTION (SHUT DOWN) mode is determined by the technician. When

EXTINCTION (SHUT DOWN) is finished the controller is switched into CLEANING,

STAND-BY or STOP mode, provided EXTINCTION (SHUT DOWN) followed as a

result of STOP button pressing.

CLEANING.

Automatic burner cleaning occurs after time set limit by programmer. In this mode

controller starts cleaning system for preset time. After this procedure controller

resets back to STANDBY mode.

AUGER (MANUAL) REFILLING.

User may activate auger manual refilling function. When device is in STOP mode,

press START and hold button for 5 seconds to start refilling. Refilling follows

according to the time programmed by the technician or until it is manually turned off

with STOP button.

AUGER EXTINCTION (EMERGENCY SHUT DOWN).

If the auger is equipped with a temperature sensor, a temperature increase above

the range programmed by the technician, it will result in activation of auger ignition

alarm. The controller turns off the fan and auger. If the burner is equipped with the

stoker, the device is switched additionally into AUGER EXTINCTION(EMERGENCY

SHUT DOWN) mode. During shut down the stoker is engaged for the time needed to

remove the ignited fuel from the stoker. In addition if the burner has cleaning

mechanism, the controller will activate the cleaning cycle and remove fuel from the

burner.

Содержание RK-2006LSPz

Страница 1: ...OPERATION MANUAL RK 2006LSPz AUGER FITTED SOLID FUEL BOILER TEMPERATURE CONTROLLER Version C820...

Страница 2: ......

Страница 3: ...electrical connection diagram For connection of stoker alarm indicator and ash removal system the additional module UM 1 shall be applied CAUTION Before plugging in the controller first check if the...

Страница 4: ...ere is 1 Display 2 Fan indicator 3 Auger indicator 4 Ignition glow plug indicator 5 Central heating circuit pump indicator 6 Hot tap water pump or mixing pump indicator 7 Room thermostat operation and...

Страница 5: ...ration mode Description STOP Boiler control stopped Controller maintains central heating and domestic water pump operation but automatic ignition does not follow STAND BY Controller maintains central...

Страница 6: ...the technician IGNITION mode follows till flame is detected If the flame is not detected within the specified time the controller activates Out of fuel alarm Pressing STOP button exceeding time limit...

Страница 7: ...ustion and the burner cool down Fan power when in EXTINCTION SHUT DOWN mode is determined by the technician When EXTINCTION SHUT DOWN is finished the controller is switched into CLEANING STAND BY or S...

Страница 8: ...s by pressing START button A L A RM O U T O F F U E L Emergency alarm Depending on construction type the boiler may be equipped with emergency sensor e g hopper cover sensor Activation of the alarm wi...

Страница 9: ...creases above 93 C it will activate STB system which will automatically engage power for central heating pump and will shut off blower Operation of STB will result in switching the controller to STAND...

Страница 10: ...omatically if repairs are made 4 Review of user settings Pressing parameter buttons 8 and 11 allows reviewing user s parameters while their activation is indicated with fast flashing of proper light F...

Страница 11: ...work time Burner start up counter 4 1 Fuel type selection RK 2006LSP controller enables programming ignition settings for four different fuel types Fuel type parameter enables switching between partic...

Страница 12: ...n follow at the same time H O T W A T E R P R I O R I T Y N O Bacterial flora liquidation in domestic water tank the controller enables manual activation of program for bacterial flora liquidation in...

Страница 13: ...ion of the temperature detector of burner fuel ignition If the system is fitted with optical fire burner detector parameters change and viewing is unavailable Burner measured temperature this paramete...

Страница 14: ...setting Table 3 Service settings Light Parameter Min Max No Language selection See description Fan Fan modulation during boiler start NO YES Min fan speed during heating up 1 100 Max fan speed during...

Страница 15: ...xtension time 1min 10min Mixing pump engaging temperature 30 C 60 C Mixing pump work hysteresis 1 C 9 C Thermostat Boiler minimum temperature 30 C 69 C Boiler maximum temperature 70 C 90 C Boiler uppe...

Страница 16: ...increase fan speed up to the selected Max fan speed during boiler start setting I G N I T I O N M O D U L S T A R T D E L A Y 5 0 s Fan speed during ignition this parameter describes power of the fan...

Страница 17: ...venge This setting is unavailable if Fan scavenge air purging setting was not selected F A N S C A V E N G E P A U S E T I M E 1 m i n Fan speed during scavenge air purging this parameter specifies fa...

Страница 18: ...programmed setting specifies feeding time in percent in relation to the time of whole work cycle F U E L D O S E F O R M A X P O W E R 5 0 Fuel feed for min burner power this parameter specifies fuel...

Страница 19: ...hed off S T O K E R E M P T Y I N G T I M E 4 0 s Auger ignition test this parameter provides functionalities of X emergency input If NO setting was selected then X input will be used for connection o...

Страница 20: ...lame of the light equals zero F D 1 C O R R E C T I O N 0 Hysteresis loss of flame depending on the type of flame detector this parameter specifies how many degrees or units in relation to the thresho...

Страница 21: ...ng mechanism In this case the output DATA is working as an external alarm CYCL means the mode in which the cleaning procedure is run after the firing and repeated at regular intervals until burner shu...

Страница 22: ...ies the minimum number of hours the burner must in order to start cleaning If the minimum time is not reached the cleaning will not run even if there was a required number of shut downs Setting the pa...

Страница 23: ...y heating system is provided with domestic water tank and charge pump this circuit may be switched off or used for control of the pump that mixes the return water in the boiler Domestic water path if...

Страница 24: ...ng is available if domestic water path EXISTS setting was selected H W P U M P W O R K E X T E N S I O N Y E S Domestic water pump extension time this parameter specifies the time lapse when domestic...

Страница 25: ...burner extinction shut down B O I L E R U P P E R H Y S T E R E S I S 5 c Burner power switching hysteresis when the programmed boiler water temperature is obtained the controller is switched to mini...

Страница 26: ...will result in cancelling of all parameters and restoration of default parameters programmed before by the fitter or technician S E R V I C E S E T T I N G S N O CAUTION Activation of this function wi...

Страница 27: ...has output DATA allows you to connect via the UM 1 module siren alarm or additional cleaning mechanism If you exit this mode the siren is in alarm it is activated in the event of sensor failure of th...

Страница 28: ...28 Figure 2 RK 2006LSP Controller connection diagram...

Страница 29: ...Settings 1 2 3 4 Thermostat Boiler max power HTW pump Domestic water desired temperature Domestic water heating priority Igniter Brightness when fuel ignition has occurred FD 1 Burner temperature with...

Страница 30: ...Fan scavenge air purging Fan scavenge air purging blow time Fan scavenge air purging pause time Fan speed during scavenge Auger Auger filling time Initial fuel feed Fuel feed cycle Fuel feed during i...

Страница 31: ...out cleaning CH pump Central heating pump work mode Central heating pump periodic work Central heating pump periodic work time HTW pump Domestic water path Domestic water heating hysteresis Boiler inc...

Страница 32: ...32...

Страница 33: ...33...

Страница 34: ...34...

Страница 35: ...0 4 11 2005 U PN EN 60730 1 2002 A1 2006 U A12 2004 A13 2005 PN EN 60730 1 2005 A14 2006 PN EN 60730 2 9 2006 PN EN 61000 3 2 2006 U PN EN 61000 3 3 1997 A1 2005 A2 2006 IS1 2006 Information on dispos...

Страница 36: ...Manufacturer Przedsi biorstwo Wielobran owe KEY 11 200 Bartoszyce ul Bohater w Warszawy 67 tel 89 763 50 50 fax 89 763 50 51 www pwkey pl e mail pwkey onet pl...

Отзывы: