Key System US Atlas IIE KSX 32i Скачать руководство пользователя страница 54

Explanation

ST

Station number.

TK

Trunk number.(20 digits)

Telephone No.  : 

”*********” represents an internal call.

TRF

Transfer the call.

Acc. No. 

Account number.

Date

Date of call (MM/DD).

Start

Starting time of call (HH:MM).

Duration

Length of calls (HH:MM:SS).

Ring

Ring time for incoming call (MM:SS).

Case Explanation

1) On October 12, 10:10 AM, Station 100 made an outgoing call on Trunk 1. The

number dialed was 29579711. The conversation lasted 1 minute and 10 seconds
and then the call was transferred to Station 113.

2) Station 113 continued the call on Trunk 1 for 5 minutes and 20 seconds. Total

time on Trunk 1 was 6 minutes 30 seconds.

3) Incoming call on trunk 4 rang for 15 seconds and was answered by station 143.

Account number 223344 was entered and the call lasted 12 minutes and 16
seconds.

4) Incoming call rang on Trunk 6 for 58 seconds but was not answered.
5) A station alarm rang Station 107 at 12:15 PM.
6) Station 104 completed an Intercom Call to Station 143 at 12:18 PM.

Содержание Atlas IIE KSX 32i

Страница 1: ...KSX 32i INSTALLATION MANUAL...

Страница 2: ...han 30 days after such malfunction whichever occurs first This warranty does not cover defects as arise from accidents neglect misuse failure of electric power air conditioning humidity control or cau...

Страница 3: ...nner to assist the installer in planning and performing the installation task system operation and feature operation Notice The information contained in this document is believed to be correct and acc...

Страница 4: ...e this device is designed to be reasonably secure against intrusions from fraudulent callers it is by no means invulnerable to fraud Therefore no expressed or implied warranty is made against such fra...

Страница 5: ...ctric shock 10 NEVER push objects of any kind into this product through the cabinet slots as they may touch dangerous voltage points or short out parts that could result in the risk of fire or electri...

Страница 6: ...Links 05 Circuit Control 05 Number Dialing Requirements 06 Power Failure 06 Equipment Description 07 Main Cabinet KSU 07 Main Control Board MCB 08 Power Supply Unit PSU 10 Trunk Card COU 11 Keyphone...

Страница 7: ...ns 22 Power Requirements 22 Grounding Requirements 22 Environmental Requirements 23 Equipment Location 24 Unpacking and Inspecting 25 Main Cabinet KSU Installation 26 Installation of Cards 27 Keyphone...

Страница 8: ...t RS 232C 44 SMDR to Serial Printer Connections 45 SMDR Format 45 Explanation 46 Case Explanation 46 Start Up Procedure 47 Power Up Procedure 47 Initialisation Procedure 48 Battery Backup Connection 4...

Страница 9: ...rations 2 03 The system uses CMOS technology space division switching to assure non blocking operation 2 04 The system is available in various hardware configurations The system cabinet has a minimum...

Страница 10: ...or Universal Cards Each Keyphone Card supports 8 Keyphone interface circuits for proprietary Keyphone connections Each Universal card supports 8 universal interface circuits supporting either Keyphone...

Страница 11: ...t the problem and must advise customers of their right to bring complaint procedures Central Office Requirements Rules and regulations for the operation and installation of telephone equipment have be...

Страница 12: ...binet Trunk lines 8 Stations Max 24 Single line Telephones Max 16 if SLU 23 if Universal Power Requirements Input Voltage 110 10 Volt 50 60Hz single phase 220 20 Volt 50 60Hz single phase Power supply...

Страница 13: ...eyphone Diameter 0 4 mm 26 gauge Max effective length 140 m 460 feet Diameter 0 5 mm 24 gauge Max effective length 230 m 750 feet Diameter 0 65 mm 22 gauge Max effective length 350 m 1150 feet Single...

Страница 14: ...E Digit period 70 ms 3 Memory dial Two types Last Number Redial and Speed Dial System speed dial 400 100 499 numbers Station speed dial 9 001 009 numbers Max digits per number 16 for Station and 24 f...

Страница 15: ...oard MCB up to two Trunk Cards COU and up to three Station Cards LNU or SLU or Universal Providing the maximum capacity of 8 trunks and 24 stations 4 03 Two metal brackets are used to attach the cabin...

Страница 16: ...ystem control software is in a 256 Kb EPROM 2 Mbit which can be upgraded and the stored program database is in battery protected RAM 4 08 The following are located on the MCB refer to Figure 2 A Memor...

Страница 17: ...FIGURE 2 Main Control Board MCB...

Страница 18: ...equipment 4 10 The fuse protection for system circuit protection is as following Fuse by Power Cord connection Power module input phased line 1 5 Amp 250 Volt Power Supply Unit F1 Battery input 3 15...

Страница 19: ...ignaling Trunk dialing output can be DTMF or pulse Mode 11 For pulse dialing the pulse per second rate Mode 13 and make break ratio Mode 14 can be set For DTMF dialing the tone duration is adjustable...

Страница 20: ...ring at up to eight flexible ring stations during day service Mode 41 and night service Mode 42 Ringing can be simultaneous or ring one station at a time in a step pattern Mode 43 l Trunk Ring at Comm...

Страница 21: ...ge of features There are also set function keys which have a range of common uses 4 22 All Keyphones are equipped with a speaker and microphone for handsfree operation and Executive Keyphones have ful...

Страница 22: ...n pickup l Locking a Station Stations can be set by the use to restrict usage When locked a station can only make intercom calls and answer incoming calls that ring on the station l DSS Unit A Keyphon...

Страница 23: ...equipped with one two or three Universal Station Cards Universal Each Universal Card supports 8 universal interface circuits for connection to proprietary Keyphones or to industry standard single line...

Страница 24: ...battery capacity Normal life expectancy for a 24 volt battery is 1 hour SMDR Unit Refer to Figure 15 5 04 The SMDR unit is an optional proprietary unit for providing Station Message Detail Records Th...

Страница 25: ...nal external source is connected at the optional equipment terminal block MOHS located on the right side of the cabinet The impedance of the music source must be less than 32 ohms with a power level o...

Страница 26: ...ipment terminal block CK2 located on the right side of the cabinet In the default state the relay is open 5 17 When DIP switch element 2 is set ON it is used as Dry Contact closure for power control r...

Страница 27: ...assign specific lines to ring at specific machines or select a machine from a station hunt group Mode 67 and set it to ring Mode 39 and 40 5 22 Outgoing calls can be set to one line exclusively or sim...

Страница 28: ...uires knowledge of proper handling techniques and the use of safeguard equipment necessary for protecting static sensitive devices 6 03 Static electricity can easily accumulate a high voltage charge i...

Страница 29: ...lines Connecting Power Cords WARNING Do not attach power supply cords to building surfaces 6 05 The basic system is supplied with a detachable power supply cord The cord should be dressed for appeara...

Страница 30: ...pe protected by a dedicated 1 5 Amp circuit breaker for 110 220 Volt AC The third wire grounding conductor of the power distribution circuits must be connected to the single point grounding bus in the...

Страница 31: ...ies Avoid installation near radio and television transmitting equipment or in buildings adjacent to broadcast antennas 6 13 The selected location for the equipment and MDF should be clean no dust dry...

Страница 32: ...WARNING The area should not be carpeted or have curtains or other material that may generate static electricity See Environmental Requirements in this section 6 16 The main cabinet is designed for wa...

Страница 33: ...e cabinet Make a note of any damages 6 23 Observing electronic equipment handling precautions remove each piece of equipment from its shipping container As each item is unpacked place it on a level wo...

Страница 34: ...net using the ten 3 mm x 6 mm screws The two keyhole slots for hanging the brackets should be above the main cabinet The power switch and power cable should be at the bottom of the cabinet Once the br...

Страница 35: ...nnections are run directly to the exterior of the cabinet Each Trunk Card COU has a single flat cable that must be connected in the correct way for the Trunk Cards to work correct 6 30 Above the Main...

Страница 36: ...FIGURE 7 Card Installation...

Страница 37: ...lephone SLU or Universal The exception being the first bottom of stack must be either Keyphone LNU or Universal The common ribbon cable requires that any Universal Card be installed at the bottom of t...

Страница 38: ...FIGURE 9 Station Card Cable Attachments...

Страница 39: ...alled Common cable connects to J11 on SLU if installed Common cable connects to J5 on Universal if installed Each Station card installed requires an individual 26 pin flat cable which connects to the...

Страница 40: ...with 0 5 mm 24 gauge wire and 140 m 460 feet with 0 4 mm wire 26 gauge Single line telephones can use a cable length of up to 1600 m 5250 feet using 0 65 mm 22 gauge cable 6 34 Each Keyphone is suppl...

Страница 41: ...run station cables inside electrical conduit already occupied by AC power cable To do so is a violation of the National Electrical Code l DO NOT run station cables near a reproduction or copying mach...

Страница 42: ...Refer to Figure 10 WARNING If the black and yellow pair is reversed the Keyphone will not function 6 40 Install the Keyphones by plugging the 1 8 m 12 foot base cord into the back of the Keyphone and...

Страница 43: ...ORN WHT GRN RED BLK YEL STATION 3 32 7 33 8 RED ORN ORN RED RED GRN GRN RED 13 14 15 16 Tip Ring DA4R DA4T WHT BLU BLU WHT WHT ORN ORN WHT GRN RED BLK YEL STATION 4 34 9 35 10 RED BRN BRN RED RED SLT...

Страница 44: ...5 6 Tip Ring STATION 2 30 5 31 6 WHT SLT SLT WHT RED BLU BLU RED 9 10 Tip Ring STATION 3 32 7 33 8 RED ORANGE ORANGE RED RED GRN GRN RED 13 14 Tip Ring STATION 4 34 9 35 10 RED BRN BRN RED RED SLT SL...

Страница 45: ...mm 8 x 0 5 inch pan head screw at each marked location Partially tighten the screws leaving approximately 6 to 8 mm protruding approx 0 25 inch l Attach the base stand to the underside of the Keyphone...

Страница 46: ...ice Announce with Answer Back allows for calls to be announced while the user is on line The OHVA module takes an additional port on the station card and two extra wires in the base cord There may be...

Страница 47: ...rt 4 Port 5 Port 5 Port 4 Port 6 Port 3 Port 7 Port 2 Port 8 Port 1 FIGURE 13 Off hook Voice Announce Connection Red Green Black Yellow White Blue White Blue Audio Tip Orange White Power 24 Volt White...

Страница 48: ...Optional Equipment Connections 7 01 Connections for most optional equipment are made on the right side of the main cabinet FIGURE 14 KSU Site Panel...

Страница 49: ...lifier input leads to the PAGE terminals on the optional equipment terminal block This provides paging output for paging zone 8 The paging output for paging zones 1 7 must be connected through station...

Страница 50: ...ANGER To reduce the risk of fire or injury to persons read and follow these instructions l Do not dispose of the battery in a fire The cell may explode Check with local codes for possible special disp...

Страница 51: ...phone activity The information is provided through either a parallel or serial port connection to a printer or computer This information includes station number trunk telephone number dialed account c...

Страница 52: ...be output via the Serial port If it is OFF then the call records will be output via the Parallel port The call records must be se to Parallel when using PC Programming 4 Intercom Calls If DIP switch...

Страница 53: ...rinter ready indication GND GND SMDR Format 8 04 The SMDR unit allows the user to analyze the systems telephone activity This information includes station number trunk telephone number dialed account...

Страница 54: ...ed was 29579711 The conversation lasted 1 minute and 10 seconds and then the call was transferred to Station 113 2 Station 113 continued the call on Trunk 1 for 5 minutes and 20 seconds Total time on...

Страница 55: ...ition Also check the interior that no loose or frayed wiring is present All stations and trunk lines should be connected and wiring checked for circuit continuity 9 03 To power up the system following...

Страница 56: ...em DIP switch element 1 to ON 6 Set the memory battery disconnect selector switch to ON up Memory protection indicator lamp red is on Battery Backup Connection WARNING Improper battery connections wil...

Страница 57: ...fully equipped and configured for operation as required by the customer and that the Power Up Procedure was accomplished successfully Station Equipment 9 07 Verify each telephone station for dial tone...

Страница 58: ...eived and the stations DSS button should be on red 2 Select trunk line key assigned by default The trunk key indicator lights green and outside dial tone is received 3 Dial the directory number of an...

Страница 59: ...26 Figure 7 Card Installation 28 Figure 8 Main Control Board MCB and COU Cable Attachments 29 Figure 9 Station Card Cable Attachments 30 Figure 10 Wiring to Modular Box 33 Figure 11 Mounting the Keyp...

Отзывы: