External Paging Amplifier Power Control
5.14. When the system is equipped with an external paging amplifier for page zone 8, it is
possible to use a power control relay to turn the paging amplifier off when not in use.
The optional paging amplifier power control is connected at the optional equipment
terminal block (CK1) located on the right side of the cabinet. The power control relay
is rated at a maximum of 3 amperes.
5.15. In the default state, the relay is open. When a paging call is made to page zone 8,
the relay closes, enabling the power circuit to the external paging amplifier. When
the paging call is terminated, the relay opens, disconnecting the power circuit.
Loud Bell / Music Source Power Control
5.16. The system has a power control relay which support two options. The function of the
power control relay is set by element 2 of the system DIP switch located on the
MCB. The optional power control is connected at the optional equipment terminal
block (CK2) located on the right side of the cabinet. In the default state, the relay is
open.
5.17. When DIP switch element 2 is set ON, it is used as Dry Contact closure for power
control relay for a loud bell which rings for incoming calls, etc. When an incoming call
is ringing the system, the relay closes, enabling the power circuit to the loud bell.
When the incoming call is answered or the ringing stops, the relay opens,
disconnecting the power circuit. Each trunk can be set to ring the loud bell in system
programming (Mode 18).
5.18. When DIP switch element 2 is set OFF, it is used as Dry Contact closure for the
external music source, etc. When background music or music-on-hold is used, the
relay closes, enabling the power circuit to the external music source. When the
music is not required, the relay opens, disconnecting the power circuit.
Auto Attendant
5.19. The system can be equipped with a proprietary Auto Attendant unit to respond to
incoming calls and direct them to a station from a hunt group, an individual station, or
the operator console. The auto attendant occupies a Keyphone port and requires a
2-pair connection.