69
EN
10.12 - Power on
11 - OPERATING MODE
11.3 - Procedure of slowdown space autoset
At any time, by pressing and holding the down arrow key P2 for
at least 2 seconds until an acoustic signal and keeping it further
pressed for another 2 seconds until sounding of a further acoustic
signal, the message
AUTS
appears on the display.
The next two manoeuvres of the door will serve to re-learn the
slowdown spaces, if the conditions of the door (frictions, etc.) have
changed since the previous learning.
11.2 -
Learning procedure
At any time, by pressing and holding the down arrow key P2 for
at least 2 seconds until the sounding of an acoustic signal, the
message
APPR
appears on the display and it is possible to
command a learning manoeuvre.
This manoeuvre begins with a radar command and consists of six
manoeuvres, three openings and three closures, during which the
door learns the stroke and its weight class (displayed as
C0
,
C1
,
C2
,
C3
,
C4
,
C5
from the lightest to the heaviest).
Based on the weight class, all the operating parameters are
automatically set, which can however be changed manually later
(see Modification of parameters).
During the learning phase, the slowdown spaces at the end of the
stroke are also self-regulated, which then remain fixed until a new
possible learning. If over time it should be noted that the slowdown
spaces are no longer optimal, it is advisable to carry out a new
learning.
ESC
MENU
OK
PROGRAM MENÙ
P5
P4
P1
P2
AS
11.4 - Operation in Bidirectional mode
A
RAD
INT
or
RAD
ESt
command causes opening of the door,
which remains open for a stay time that can be modified by the
user (see Changing parameters) and then closes again.
A
RAD
INT
or
RAD
ESt
command during opening is ignored.
A
RAD
INT
or
RAD
ESt
command during closing causes
immediate reopening.
(*) With the use of the SMNPAE selector the
RESt
and
FArM
functions are no longer available. The Key logo indicates the
APAr
function.
If the selector is not installed (it is not detected when the appliance
is turned on), the default operating mode is bidirectional.
In the event that the selector is no longer detected during operation
(because it is disconnected or due to the interruption of the
connection), the operating mode becomes Bidirectional, unless
the Block or Free functions are active, which are maintained for
safety reasons .
11.1 -
The operating modes
When the device is switched on, the display of the control unit shows
the version of the installed firmware for 2 seconds (e.g. r2.11) and then
displays the currently selected type of motor (A4) for 2 seconds.
The displayed motor must be A4: if the control unit displays a different
motor, the motor type must be set with the following procedure.
Turn on the device by holding down the OK button (next to the display)
until sounding of the acoustic signal; at this point the display will show the
code: “0000”. With the keys “+” and “-” the first two and the last two digits
of the number can be modified separately. Enter “4444” and keep OK
pressed until sounding of the acoustic signal.
Restart the control unit and at this point the display will show the correct
A4 motor.
N.B. Until the first learning manoeuvre is completed, all parameters
will be reset to the default value each time the power is turned on
or reset.
When the electronic board is switched on, the first movement of
the door must be closed and performed at reduced speed.
CHANGE OF OPENING DIRECTION
Enter the control unit menu by pressing the “ESC” button for 2 sec
(until sounding of the acoustic signal): this enters the modification
of parameters. Use the “ESC” key to scroll through the parameters
until reaching parameter “H” (motion direction): bring the value to
“0” (The default is “1”). Press the “OK” button until sounding of the
acoustic signal to confirm. The control panel will perform a new
learning of the work dimensions.
ATTENTION !
Normally the display shows, at intervals of approximately 5
seconds, the operating mode set by the selector:
bdIr
- Bidirectional
FrEE
- Free
rInt
- Output
rESt
- Input (*)
APAr
- Partial Opening (*)
bLOC
- Block
OPEn
- Open
FArM
- Pharmacy (*)