10
EN
2 -
PRODUCT OVERVIEW
2.1 - Description of the product
The UNDER
gear motors are destined to be installed in systems for
the automation of gates with hinged doors.
The UNDER
gear motors have been designed and constructed to be
fitted onto hinged doors within the weight limits indicated in the
technical specifications table.
The use of gear motors for applications which differ from those
indicated above is prohibited.
2.2 - Model and technical characteristics
3 - PRELIMINARY CHECKS
Before installing this product, verify and check the following steps:
- Check that the gate or door are suitable for automation
- The weight and size of the gate or door must be within the maxi
-
mum permissible operating limits specified in Fig. 2
- Check the presence and strength of the security mechanical stops
of the gate or door
- Check that the mounting area of the product is not subject to flood
-
ing
- Conditions of high acidity or salinity or proximity to heat sources
could cause malfunction of the product
- Extreme weather conditions (for example the presence of snow,
ice, high temperature range, high temperatures) may increase the
friction and therefore the force required for the handling and initial
starting point may be higher than under normal conditions.
- Check that the manual operation of gate or door is smooth and
friction-free and there is no risk of derailment of the same
- Check that the gate or door are in equilibrium and stationary if left
in any position
- Check that the power line to supply the product is equipped with
proper grounding safety and protected by a magnetothermal and
differential security device
- Provide the power system with a disconnecting device with a gap
of contacts enabling full disconnection under the conditions dictated
by the overvoltage category III.
- Ensure that all materials used for the installation comply with cur-
rent regulations
Code Description
INT
For swing gates with maximum length 3,5 m, 230 Vac motor, with opening and closing mechanical stops.Cable length 1.5 m
INTOIL
For swing gates with maximum length 3,5 m, 230 Vac motor, with opening and closing mechanical stops.Cable length 1.5 m,
lubricated in oil bath
INT10
For swing gates with maximum length 3,5 m, 230 Vac motor, with opening and closing mechanical stops. Cable length 10 m
INT24
For swing gates with maximum length 3,5 m, 24 Vdc motor, without encoder, with opening and closing mechanical stops
TECHNICAL DATA
MODELS
INT
INTOIL
INT10
INT24
TECHNICAL SPECIFICATIONS
Torque
Nm
300
300
300
250
Working cycle
%
30
30
30
80
Opening time at 90°
sec
20
20
20
18-25
Control board
CT202
CT202
CT202
14AB2
Power supply
Vac (Vdc)
230
230
230
(24)
Absorption
A
1
1
1
5
Engine power
W
230
230
230
120
Capacitor
µF
10
10
10
-
Thermoprotection
°C
150
150
150
-
Degree of protection
IP
67
67
67
67
Dimensions (L - P - H)
mm
412 - 346 - 160
412 - 346 - 160
412 - 346 - 160
412 - 346 - 160
Weight
Kg
11
11
11
10,8
Operating temperature
°C
-20°+55°
-20°+55°
-20°+55°
-20°+55°
Leaves maximum weight
Kg
600
600
600
600