![Key Automation CT202 Скачать руководство пользователя страница 6](http://html.mh-extra.com/html/key-automation/ct202/ct202_instructions-and-warnings-for-installation-and-use_1960074006.webp)
18
EN
4 - PRODUCT INSTALLATION
POWER SUPPLY CONNECTOR AND MOTOR
L
230 Vac (120 Vac) 50-60 Hz power supply phase
N
230 Vac (120 Vac) 50-60 Hz power supply
neutral
L1
Motor phase
L2
Motor phase
COM
Motor common
L1
Motor phase
L2
Motor phase
COM
Motor common
COURTESY L.
Courtesy light, 230 Vac (120 Vac) 100 W
FLASH
Flashing light, 230 Vac (120 Vac) 40 W
POWER SUPPLY CONNECTOR
Set on “ON” to disable inputs EDGE, PH2, PH1, STOP.
Eliminates the need to bridge the terminal board inputs.
WARNING - with the dip switch ON, the safety devi-
ces are disabled
4.1 - Electrical connections
WARNING - Before making the connections, ensure that the control unit is not powered up.
2
3 4
1
1 2
TX
RX
NC
PH2
2
3 4
1
1 2
TX
RX
PH1
N
L
+24 Vdc
24 Vac
24 Vac
EL
EL
GND
+ 24 TX PH
EDGE
EDGE PH2
PH1
STOP
OPEN
CLOSE
PED
SS
COM
L
N
UP
DOWN
MENU
SS
COURTESY L.
COURTESY L.
FLASH
FLASH
OUTPUT 24 Vdc
OUTPUT 24 Vac
GND
_
12/24
AC/DC
GND
_ 12/24
AC/DC
COM OUT
GND
_ 12/24
AC/DC
GND
_ 12/24
AC/DC
COM OUT
NC
M
1
M
2
COM
L1
L2
COM
L1
L2
M1
M2
1 = EDGE
2 = FOTO 2
3 = FOTO 1
4 = STOP