19
ENGLISH
FUNCTIONS \ VALUES
ELECTRONIC CLUTCH
(sensitivity)
--
Maximum
Average
maximum
Average
minimum
mini-
mum
Sensitivity selection parameter:
Maximum sensitivity= minimum
force
MOTOR SPEED
--
Minimum
Maximum
Motor speed selection parameter
AUTOMATIC CLOSURE
(seconds)
NO
YES
pedes-
trian only
Automatic closure selection parameter
OPEN COMMAND
Open
Stop
Close
Open Close
Activating the P/P function prevents the automation from stop-
ping; remember that this enabled function may be critical for
automations with great inertia
CONDOMINIUM
(OPENING ONLY)
NO
YES
Activating the condominium function, the first P/P impulse opens
and only accepts reopening while the door is closing
ELECTRIC LOCK
BATTERING RAM
NO
YES
(only when
opening)
YES
(when
opening /
closing)
Selecting the Battering ram parameter, the control
unit will permit the releasing and coupling of the
electric lock, commanding the closing motors for a
brief period of time
SP/LC OUTPUT
Indicator
on
Courtesy
light
Selection parameter for output as an open gate indicator or courtesy light
Parameter G=0 enables the gate open indicator where the
flasher frequency indicates the automation status :
•
slow while opening
•
quick while closing
•
on steady when the gate has stopped open
•
it turns off with the gate closed
Parameter G=1 enables the courtesy light timed for 90 sec. from
the first opening or closing impulse
% SLOW MOTION
NO
10%
20%
30%
40%
% of travel in slow motion
selection parameter
SLOW MOTION SPEED
--
low
Medium
low
Medium
high
High
Speed during slow motion
selection parameter
LIMIT SWITCH
NO
YES
Motors with electric limit switch selection parameter (SN50-24)
No. OF MOTORS
--
1
2
1 or 2 motor automation selection parameter
PRE-FLASH
NO
1 sec
2 sec.
3 sec.
8 sec.
Activating the Pre-flash func
-
tion, the flasher is activated
for the selected period of time
before each closing movement
CLOSE AFTER TRANSIT
NO
YES
Activating the Close after Transit function, with automatic closure
activated, permits the closure of the automation in the shortest
period of time without waiting for the automatic reclosure
TIMER / MAGNETIC LOOP
(to be connected on P/P)
NO
YES
When you activate the function Timer / Magnetic Coil via parameter P after
terminating total opening if step/step contact is kept closed the automatic
closing time is locked so that the gate never closes until the step/step
contact is opened again, if there are several step/step impulses during the
standby time for automatic closing the time will be continuously reset
SOFT START
NO
YES
Activating the Soft Start function, during the first seconds of
movement of the automation, the control unit will command the
motor to operate at a reduced speed for a softer start
SOFT STOP
NO
YES
Activating the Soft Stop function, during the last seconds of
movement of the automation, the control unit will command the
motor to operate at a reduced speed for a softer arrival
PHOTOCELL F2
OPERATION
active
only
when
opening
active when
opening and
closing
Selection parameter for F2 operation when opening or when
closing
MOTOR TYPES
PS-200
PS300-
24/400-24
SN-20
SN50-24 INT-24 Motorisation type selection
parameter
COUNTER
NO
4=40000
Activating the function, selecting a value between 1 and 9 (1 value
=10000 manoeuvres) it is possible to set a maximum number of ma-
noeuvres that as they decrease will signal the request for service with
regular luminous flasher signals upon automation closure. To reset the
count hold down the S2 enter and S1 up/dwn buttons together for 5 sec.
N.B.: each function variation is confirmed upon completion of closure