BATTERY KIT

A system with the CT-824S can operate even if there is a mains power outage by installing two 12V 

2.2Ah batteries (not supplied) without making any change to the system. 

Connection sequence:

• 

Disconnect the 230Vac power supply

• 

Connect the two batteries in sequence paying attention to the terminal polarity No.33 BAT+ 

and No. 34 BAT-

• 

Check that the safety LED’s come on

• 

Re-connect the mains power supply

• 

New batteries charge up after about ten hours.

The number of manoeuvres that can be performed with the battery supply depends on many fac-

tors; an approximate example could be 4 complete cycles under the following conditions:

• 

hinged doors 3 mt 250 kg

• 

system with 1 pair of photocells, snap-in receiver and 1 flasher (20W max.) 

• 

batteries charged

• 

within 5 hours of 230V power supply failure

FINAL WARNINGS

• 

The installation of the automation must be performed properly by qualified personnel in pos

-

session of legal requirements and in compliance with machine directive. 

• 

Check the solidity of existing structures (columns, hinges, doors) in relation to the force gen

-

erated by the motor. 

• 

Check that there are suitably sturdy mechanical stops at the end of opening and closing 

travel of the doors. 

• 

Analyze the risks of the automation and adopt necessary safety measures and warnings. 

• 

install controls (such as the key selector) so that the user is not in a hazardous position. 

• 

Upon completion of installation, check the safety devices several times, as well as those for 

signalling and automation release. 

• 

Provide the automation with the EC label or tag that contains the danger information and 

identification data. 

• 

Give the final user the instructions for use, safety warnings and the EC declaration of con

-

formity. 

• 

Make sure the user understands proper automatic, manual and emergency operation of the 

automation.

• 

Inform the user in writing (for example in the instructions for use) of any unprotected residual 

risks and foreseeable improper use. 

• 

Provide a maintenance schedule for the system (at least every 6 months for the safeties) 

with an appropriate register of work performed. 

• 

Keep this instruction manual for future reference.

• 

Key Automation S.p.A. reserves the right to make, at any time, any modifications which may 

be required to improve appearance and/or operation.

DISPOSAL

This product is composed of various components which may in turn contain pollutants. 

Do not dispose of it in the environment! Find out about the method for recycling or dis-

posing of the product in compliance with current local laws

Содержание 900CT-824S

Страница 1: ...L DE INSTRUCCIONES MANUAL DE INSTRUÇÕES INSTRUKCJA OBSŁUGI GEBRUIKSHANDLEIDING Centrale elettronica Electronic control unit Centrale électronique Elektronische Steuereinheit Central electrónica Central electrónica Elektroniczna jednostka sterująca Electrische zekering 900CT 824S Key Automation S p A ...

Страница 2: ...after removing the cause replace it with another one of the same type Install the various safety devices limit switches photocells sensitive rib stop button If one or more of the safety devices are not installed the corresponding terminals must be short circuited with the controls common All contacts N C Assigned to the same input must be connected in series All contacts N O Assigned to the same i...

Страница 3: ...PTION CN1 Power supply 95 255 Vac CN2 Supply engines and accessory CN3 Connection safeties CN4 Connection exit Controls and safeties CN5 Connection antenna and second radio channel CN6 Connection batteries and accessory supplyes 24Vdc CN7 Connection encoder JP1 Connector for radio receiver DSP1 Display for signalling functions and safety inputs S1 Button for scrolling programming functions see tab...

Страница 4: ...ic lock output connection 9 ELS Electric lock output connection At the opening command it turns on for 1 sec Before activating door M1 10 LAMP Flasher connection max 25W 24Vdc 11 COM OUT Common link Blinking light gate open courtesy light 12 SP LC Gate open indicator courtesy light max 3Watt 24Vdc for higher power levels it is recommended to connected a relay sized for the applied load to this out...

Страница 5: ...ep Step Function N O contact Normally Open Input of the Open Close or Open Stop Close command based on the selection of Parameter D 20 F1 Connection of the Close Photocell F1 N C contact Normally Closed This input is considered a safety the contact can be interrupted at any time during closing of the automation causing an immediate stop in movement and reversing the direction of movement 21 F2 Con...

Страница 6: ...pply of the encoders 30 ENC1 M1 Signal of the encoder for motor M1 31 ENC2 M2 Signal of the encoder for motor M2 32 Negative power supply of the encoders The electronic brake is always active in both operating directions when it intervenes the operation reverses for both doors for 2 seconds then the movement is stopped for 1 second then it continues motion in the direction opposite of the obstacle...

Страница 7: ...ns of use the LCD dots must not flash or be on steady they turn on or flash if the corresponding safety is tripped By using a new P P command check that the complete opening of the door is carried out up to the stop At this point press the P P button again and check the complete closing of the door up to the stop After having verified the correct complete opening and closing enable the deceleratio...

Страница 8: ...n will cause the M1 door to close in order to self learn the desired door delay time N B If you want to have the door delay time equal to 0 simply press the P P button two times after learning the automatic closure time 6 Once both doors have closed completely the programming procedure will end automatically N B Depending on the maximum opening stop point in normal operation the control unit will ...

Страница 9: ...r PRE FLASH NO 1 sec 2 sec 3 sec 8 sec Activating the Pre flash func tion the flasher is activated for the selected period of time before each closing movement CLOSE AFTER TRANSIT NO YES Activating the Close after Transit function with automatic closure activated permits the closure of the automation in the shortest period of time without waiting for the automatic reclosure TIMER MAGNETIC LOOP to ...

Страница 10: ...the end of opening and closing travel of the doors Analyze the risks of the automation and adopt necessary safety measures and warnings install controls such as the key selector so that the user is not in a hazardous position Upon completion of installation check the safety devices several times as well as those for signalling and automation release Provide the automation with the EC label or tag ...

Страница 11: ...ndro Volta 30 30020 Noventa di Piave Ve Italia T 39 0421 307 456 F 39 0421 656 98 info keyautomation it P IVA 03627650264 C F 03627650264 Capitale Sociale Euro 400 000 00 i v Reg Imprese di Venezia n 03627650264 REA VE326953 www keyautomation it 580ISCT 824 rev05 ...

Отзывы: