![Kettler Quadriga Duo Speed 45 Скачать руководство пользователя страница 111](http://html1.mh-extra.com/html/kettler/quadriga-duo-speed-45/quadriga-duo-speed-45_operating-and-maintenance-instructions-manual_1958686111.webp)
MY20K10 - 12_1.0_11.01.2021
111
Documents
Inspection
Tests
Maintenance
Accept-
ance
Rejection
Light system
Rechargeable
battery
6 months
First examination
O.K.
Error message
Contact battery
manufacturer;
take out of
service
, new battery
Light cabling
6 months
Connections, correct
wiring
O.K.
Cable defective,
no light
New cabling
Rear light
6 months
Side light
Functional check
O.K.
No constant light
New rear light as specified in
parts list; replace if
necessary
Front light
6 months
Side light, daytime
riding light
Functional check
O.K.
No constant light
New front light as specified
in parts list; replace if
necessary
Reflectors
6 months
All complete, state,
fastening
O.K.
Damaged or not
all complete
New reflectors
Drive/gear shift
Chain/cassette/
pinion/
chainring
6 months
Check for damage
O.K.
Damage
Refasten if necessary or
replace as specified in parts
list
Chain guard/
spoke guard
6 months
Check for damage
O.K.
Damage
Replace as specified in parts
list
Bottom bracket
axle/crank
6 months
Check mount fastening
O.K.
Loose
Retighten screws
Pedals
6 months
Check mount fastening
O.K.
Loose
Retighten screws
Shifter
6 months
Check mount fastening Functional check
O.K.
Loose
Retighten screws
Shift cables
6 months
Check for damage
Functional check
O.K.
Loose or
defective
Adjust shift cables; new shift
cables if necessary
Front derailleur
6 months
Check for damage
Functional check
O.K.
Gear shift difficult
or not possible
Adjust
Rear derailleur
6 months
Check for damage
Functional check
O.K.
Gear shift difficult
or not possible
Adjust
Electric drive
Display
6 months
Check for damage
Functional check
O.K.
No screen,
defective screen
display
Restart, test battery, new
software, or new display –
take out of service
,
Electric drive
control panel
6 months
DriveCheck for
damage
Functional check
O.K.
No response
Restart; contact control
panel manufacturer, new
control panel
Tachometer
6 months
Speed measurement
O.K.
S pedelec
travelling 10%
too fast/slow
Take the S pedelec out of
service until the source of
the error is found
Cabling
6 months
Visual inspection
O.K.
Failure in
system, damage,
kinked cables
New cabling
Battery mount
6 months
Firmly in position, lock,
contacts
Functional check
O.K.
Loose; lock
doesn't close, no
contacts
New battery mount
Motor
6 months
Visual inspection and
mount
O.K.
Damage, loose
Refasten motor, contact
motor manufacturer, new
motor;
take out of service
Software
6 months
Check version
In latest
version
Not latest version Import update
Components
Frequency
Description
Criteria
Measures if rejected
Содержание Quadriga Duo Speed 45
Страница 113: ...MY20K10 12_1 0_11 01 2021 113 Documents Notes...
Страница 114: ...MY20K10 12_1 0_11 01 2021 114 Documents 11 4 Charger operating instructions 0123435678 9 78 7 3951 8 ABC D ABC D ABC...
Страница 116: ...MY20K10 12_1 0_11 01 2021 116 Documents D Compact Charger A G A C EBE D F...
Страница 117: ...MY20K10 12_1 0_11 01 2021 117 Documents D EBE D F A G A C...
Страница 118: ...MY20K10 12_1 0_11 01 2021 118 Documents D A G A C EBE D F...