CAUTION

!

WARNING

!

Your Kestrel Weather/Environmental Meter is designed to provide accurate 

measurement of current conditions only. Depending on your location and 

environment, conditions may change rapidly.

Rapid temperature and humidity changes (i.e., moving your meter from indoors to outdoors) may cause inaccurate readings of 

temperature and humidity as well as all readings that rely on either of these values. Before relying on readings from your Kestrel Meter, be 

sure to either a) force air flow over the sensors by waving or slinging your meter through the air; or b) wait until your unit’s readings have 

stabilized, indicating it has equilibrated to its new environment.

To maximize the accuracy and reliability of your readings:

•  Ensure that your Kestrel Meter is in good repair and within factory calibration.

•  Take readings frequently and carefully according to the guidelines above.

•  Allow your meter’s readings to stabilize after significant changes in temperature or humidity (i.e., changing location from indoors 

to outdoors).

•  Allow a margin of safety for changing conditions and reading errors (2-3% of reading is recommended).

Use care and good judgment when referring to your Kestrel Meter to make any decisions regarding safety, 

health or property protection.

To reduce the risk of injury or death to persons, read and follow these guidelines! 

Your Kestrel Weather/Environmental Weather Meter may provide one or more of these measurements relating to estimation of danger of 

injury to people or animals from heat or cold: Heat Stress Index, Wind Chill Index, Wet Bulb Globe Temperature (“WBGT”), Thermal Work 

Limit (“TWL”). Note that guidance tables based on these values are based on typical physiological response. Certain individuals or animals 

may be more susceptible to harm relating to environmental conditions and require additional precautions. For example, very young or 

elderly individuals, individuals with asthma, and individuals who have not become acclimatized to hot conditions are likely to be more 

prone to heat injury. 

•   Know yourself and the individuals and items you are responsible for.  

 

•  Where appropriate, seek the guidance of a medical professional. 

•  Know what to do in the event of heat or cold injury and be prepared with supplies.

•  In the case of heat illness, remember the rule – “Cool first, transport second.” An inexpensive ice bath can mean the difference 

between life and death.   

 

Your Kestrel Weather/Environmental Meter is not a medical device. It is only one source of information and 

must be employed with care and good judgment.

We recommend that ONLY Lithium AA batteries 
be used in your Kestrel Weather/Environmental 
Meter to provide the widest operating 
temperature range and to avoid damage caused 
by leaking lead-acid batteries. If you must use 
conventional AA batteries, please do not store 
your Kestrel Meter with the batteries in place. 
Damage caused by battery corrosion is not 
covered under warranty.

WARNING: Lithium is a toxic substance and 
ingestion may cause serious injury or death. Keep 
lithium batteries out of the reach of children. If 
swallowed, immediately seek medical help. Have 
doctor phone 24-hour hotline at (202) 625-3333, 
call collect if necessary. Dispose of batteries 
properly and according to local regulations. Do 
not puncture or burn batteries. If the battery 
compartment does not close securely, stop using 
the product and keep it away from children.

BATTERIES

This Quick Start Guide contains only the information you 
need to get started using your Kestrel meter. For a full 
user manual with in-depth explanations of these topics, 
FAQ’s, chat and e-mail support, visit  

www.kestrelinstruments.com.

CONTACT US AT 

(800) 784-4221 Toll Free North America

(610) 447-1555

Email: [email protected]

Facebook: Fb.com/KestrelMeters

Twitter: @KestrelWeather

Содержание 5500

Страница 1: ...QUICK START GUIDE Kestrel 5500 Weather Meter www kestrelinstruments com ...

Страница 2: ...ions Forexample veryyoungor elderlyindividuals individualswithasthma andindividualswhohavenotbecomeacclimatizedtohotconditionsarelikelytobemore pronetoheatinjury Knowyourselfandtheindividualsanditemsyouareresponsiblefor Whereappropriate seektheguidanceofamedicalprofessional Knowwhattodointheeventofheatorcoldinjuryandbepreparedwithsupplies Inthecaseofheatillness remembertherule Coolfirst transports...

Страница 3: ...sary 17 Impeller Replacement 18 Warranty Certificate 19 MEASUREMENTS Icon 5000 Environmental 5100 Racing 5200 Professional 5500 Weather 5400 HST Wind Speed Air Speed mph fpm Bft m s km h kt Temperature F C Wind Chill F C Relative Humidity Heat Stress Index F C Dewpoint Temp F C Wet Bulb Temp F C Station Pressure inHg hPA psi mb Barometric Pressure inHg hPA psi mb Altitude m ft Density Altitude m f...

Страница 4: ... Wet Bulb Temp F C FEATURES 5000 Environmental 5100 Racing 5200 Professional 5500 Weather 5400 HST LiNK Connectivity Kestrel LiNK Mobile App N A o o o o o Backlit Display switchable white or Night Vision preserving red N A o optional GETTING TO KNOW YOUR KESTREL BACK DATA TRANSFER PORT SERIAL NUMBER AA BATTERY 1 Lithium recommended LANYARD ATTACHMENT PRESSURE SENSOR FRONT OPTIONS EXIT POWER BACKLI...

Страница 5: ...reen or the main Targeting Screen BLUETOOTH Bluetooth On Off Conct DATA PORT MEMORY OPTIONS Clear Log Auto Store Store Rate Overwrite GRAPH SCALE DISPLAY Auto Shutdown Contrast Backlight SYSTEM Time Date Compass Cal Measurements Units Lang Batt Factory Restore ABOUT Version Legal KESTREL OPTIONS MENU KESTREL MENU NAVIGATION TYPES OF MENU ITEMS Tasks are executed by highlighting the field and press...

Страница 6: ...s possibleformaximumaccuracy 5 EXIT OPTIONS MENU ADDITIONAL SETTINGS All additional settings are accessed from the options menu 1 SET AUTO STORE RATE Scroll to and select Memory Options Scroll to Auto Store and ensure it is set to ON Scroll to Store Rate and adjust to desired frequency of automatic weather data logging 2 SET OVERWRITE GETTING STARTED Scroll to and select Memory Options Scroll to O...

Страница 7: ... all measurements Each new Min Avg Max capture overwrites the previously captured value from all measurements CAPTURING MIN AVG MAX VALUES Scroll to the Min Avg Max Screen of the desired measurement This can be done by scrolling right from the desired Current Measurement Screen or scrolling vertically from another measurement s Min Avg Max Screen Press Select to Start a new Min Avg Max capture Pre...

Страница 8: ... stamped data log of all measurements at the logging interval you set Additional log points can also be captured manually Logged data can be accessed four ways Viewed on the Kestrel Meter on the Data Graph Screen and Data Log Detail Screens Exported to an iOS or Android mobile device using the Kestrel LiNK mobile apps available in the App Store and Google Play Store Requires a Kestrel LiNK enabled...

Страница 9: ...oose a file export directory on your computer and click on the Ok button DIRECTION Compass heading in true or magnetic WIND SPD Wind Speed is the measurement of the wind passing through the impeller For greatest accuracy point the back of the Kestrel directly into the wind CROSWND Crosswind uses the internal compass and a user selected heading to calculate the crosswind component of the full wind ...

Страница 10: ...t caused by a manufacturing defect normal usage wear and failed batteries Measurement accuracy is warranted to be within the specifications on the supplied Certificate of Conformity including specified drift since date of manufacture If no warranty registration or proof of purchase is provided the warranty period will be measured from the meter s date of manufacture Except for the warranties set f...

Страница 11: ... designed and manufactured in the USA NIELSEN KELLERMAN 21 Creek Circle Boothwyn PA 19061 Phone 610 447 1555 Fax 610 447 1577 Web NKhome com Email info NKhome com By Please register your Kestrel Meter at www kestrelinstruments com 319039_0_15 10 16 ...

Отзывы: