5.   GENERAL INFORMATION
TO SHUT DOWN THE BOILER

Note.  The inbuilt frost protection for the boiler 

will not function if there is no mains supply 

to the boiler.

1.  For short periods

Set the external controls to OFF.  Wait 4 

minutes and then isolate the mains supply 

to the boiler.

2. For longer periods

Set the external controls to OFF.  Switch 

the electricity supply to OFF.  For longer 

periods the entire system should be drained, 

including the domestic hot water supply.

TO RELIGHT THE BOILER

Refill the system if it has been drained, 

taking care to ensure no air is in the boiler 

or system.
Repeat the procedure detailed in ‘To light 

the boiler’.

FROST PROTECTION

The KESTON HEAT2 boiler has built into its 

control system the facility to protect the boiler 

only against freezing.  

Note

. This may not protect remote parts of 

the system, in which case a separate frost 

thermostat should be fitted.

BOILER OVERHEAT THERMOSTAT

Boiler overheating is detected by electrical 

sensors connected to the boiler control 

module.  If the boiler overheats it will shut 

down and the display will show Overheat 

Lockout.  Press the reset button and the 

boiler will relight.  If the fault recurs turn off 

the  boiler  and  consult  a  suitably  qualified 

Gas Safe registered engineer or in IE a 

competent person. 

CONDENSATE DRAIN

This appliance is fitted with a siphonic 

condensate trap system that reduces the risk 

of the appliance condensate from freezing.  

However should the condensate pipe to 

this appliance freeze, please follow these 

instructions:
a. If you do not feel competent to carry out 

the defrosting instructions below please call 

your local Gas Safe Registered installer for 

assistance.
b. If you do feel competent to carry out the 

following instructions please do so with care 

when handling hot utensils.  Do not attempt to 

thaw pipework above ground level.
If this appliance develops a blockage in its 

condensate pipe, its condensate will build 

up to a point where it will make a gurgling 

noise prior to locking out displaying “Ignition 

Lockout” on the display.  If the appliance is 

reset it will make a gurgling noise prior to it 

locking out displaying “Ignition Lockout” on 

the display.
To unblock a frozen condensate pipe;
1. Follow the routing of the plastic pipe from 

its exit point on the appliance, through its 

route to its termination point.
Locate the frozen blockage.  It is likely that 

the pipe is frozen at the most exposed point 

external to the building or where there is 

some obstruction to flow.  This could be at 

the open end of the pipe, at a bend or elbow, 

or where there is a dip in the pipe in which 

condensate can collect.  The location of the 

blockage should be identified as closely as 

possible before taking further action.
2. Apply a hot water bottle, microwaveable 

heat pack or a warm damp cloth to the frozen 

blockage area.  Several applications may 

have to be made before it fully defrosts.  

Warm water can also be poured onto the 

pipe from a watering can or similar.  DO NOT 

use boiling water .
3. Caution when using warm water as 

this may freeze and cause other localised 

hazards.

Содержание Heat2 45

Страница 1: ...conform to the safety and performance specification that we require Do not use reconditioned or copy parts that have not been clearly authorised by Keston For the very latest copy of literature for sp...

Страница 2: ...3 Installer Connections 20 4 Faults 21 Faults Hardware Thermistors Actuators 22 Faults Temperature Supervisions 23 Faults System Flame Fan Hydraulic etc 24 Faults Internal System 25 5 General Informat...

Страница 3: ...s or rules in force In your own interest and that of safety it is the law that this boiler must be installed and maintained by a suitably qualified Gas Safe registered engineer or in IE a competent pe...

Страница 4: ...rials giving off flammable vapours must not be stored in the same room as the appliance This appliance can be used by children 8 years and above Also persons with reduced physical sensory or mental ca...

Страница 5: ...normal operation screen and highlight the first menu item Enter the highlighted menu sub menu or parameter if in a menu or sub menu If in a parameter setting select a parameter which will then flash f...

Страница 6: ...o Day If there is a local DHW circuit set the DHW Operating mode DHW1 Boiler 1 to Day If there is an extension module configured with Heating circuits or DHW circuits set the Operating mode to Day e g...

Страница 7: ...acity Set point 40 Capacity 0 KESTON HEAT 2 55kW Status OpenTherm Operation Day Room set point 20 0 C Flow set point 60 0 C KESTON HEAT 2 55kW Status Operation Night Tank temperature 45 0 C Flow set p...

Страница 8: ...e holiday HC1 Boiler 1 1 Operating mode Standby Room temperature HC1 Boiler 1 1 HC2 Boiler 1 2 1 Heating Circuits a Operating mode selection Every heating circuit can be individually set to one of the...

Страница 9: ...Day Night Holiday e g Flow temperature day 70 0 Heating circuits Flow temperature Settings Time clock Holiday program Settings HC1 Boiler 1 1 d Settings Each heating circuit has a number of settings t...

Страница 10: ...imit Heating limit switch Heating limit temperature Heating limit Heating limit switch Heating limit temperature Heating limit switch On Off ii Heating Limit Heating limit can be enabled for a heating...

Страница 11: ...onfigured for a heating circuit the switching differential may be set HC1 Boiler 1 1 Room temp switch diff Pump Frost protection Pump Overrun time Overrun speed Maximum speed iv Pump The heating circu...

Страница 12: ...ction Flow temperature Outside temperature Room temperature v Frost Protection The heating circuit frost protection can be set to be triggered on a number of temperature sources if configured Frost Pr...

Страница 13: ...ysteresis Temperature 0 C Hysteresis 5 C Frost protection Flow temperature Outside temperature Room temperature Room temperature Temperature Hysteresis Temperature 6 C Hysteresis 2 C Frost protection...

Страница 14: ...grammed to a specific time clock with three periods per day single days individually Monday through to Sunday or multiple days Monday to Friday or Saturday and Sunday Single Multiple e g Heating circu...

Страница 15: ...any of the following The DHW circuit when configured has the following settings DHW1 Boiler 1 Standby DHW Operating mode Tank temperature Flow temperature DHW1 Boiler 1 Tank temp day Tank temp night...

Страница 16: ...are only accessible at Installer access levels Day Night Holiday e g DHW1 Boiler 1 One time boost Primar pump Legionalla On Off One time boost One time boost On Off Temperature On Off One time boost O...

Страница 17: ...mp Overrun time Overrun speed Minimum speed Maximum speed ii Primary pump This is where the pump control parameters for the Hot Water Tank primary charge pump may be set Overrun time 10secs Overrun sp...

Страница 18: ...peration mode Temperture Interval Legionella Temperture Interval iii Legionella The legionella functionality can be set to either a fixed weekday or a time interval The temperature can also be set iv...

Страница 19: ...grammed to a specific time clock with three periods per day single days individually Monday through to Sunday or multiple days Monday to Friday or Saturday and Sunday Single Multiple e g DHW circuits...

Страница 20: ...Multifunctional 230V 50Hz Typical setting SL1 Heating Circuit 1 SL2 Heating Circuit 2 DHW l3 Optional Interlock input 230V 50Hz l4 Auxiliary Mains Supply Output 230V 50Hz Live Neutral Internal Pump Po...

Страница 21: ...button whilst in this display If there are multiple faults then a list of faults will be shown e g Each fault may be highlighted and selected to show the detail as above KESTON HEAT 2 55kW Operation H...

Страница 22: ...cking 6 W DHW thermistor open circuit 7 W DHW thermistor short circuit 8 W Outside thermistor defect open short 9 B Water pressure sensor defect 10 L Flow thermistor open circuit lockout after 24h 11...

Страница 23: ...to flue overheat 32 B Flow return reversed 33 B Thermistor pipe fit supervision active blocking 34 L Thermistor pipe fit supervision lockout 35 B Flow gradient supervision 36 B Flue gradient supervisi...

Страница 24: ...e used 56 L False flame with heat demand 57 L No flame after restarts 58 B L Fan speed stand still check 59 L Fan speed not achieved e g Pre purge test post purge test etc 60 B L Error fan speed durin...

Страница 25: ...RIPTION ERROR CODE OpenTherm INTERNAL SYSTEM L Request for re update 94 B Blocking due to programming mode 95 L Lockout parameter mismatch 96 L Lockout parameter set 97 B L Internal blocking error 98...

Страница 26: ...uld the condensate pipe to this appliance freeze please follow these instructions a If you do not feel competent to carry out the defrosting instructions below please call your local Gas Safe Register...

Страница 27: ...ginal setting once cold spell is over Place the heating on continuous and turn the room stat down to 15 C overnight or when unoccupied Return to normal after cold spell ESCAPE OF GAS Should a gas leak...

Страница 28: ...policy of continuing improvement in the design and performance of its products The right is therefore reserved to vary specification without notice E V E R Y T H I N G I S P O S S I B L E SYSTEM SET...

Отзывы: