37
5. Set the ZSAC control jumper as shown in Figure 3.28.
6. Install the amplifier bottom cover.
7. Ensure the amplifier is switched
OFF
.
8. Plug the amplifier into the AC mains.
The first portion of this test will re-confirm operation of the Step-Start and expected High-
Voltage operation. When switched
ON
, the High-Voltage will begin to “ramp” up, then
“plateau” until the Step-Start Relay is energized. At that moment, the High-Voltage should
reach normal levels (approximately 2kV when “MODE” switch is set to
CW
, and approxi-
mately 3kV with “MODE” switch set to
SSB
).
1. Set the “MODE” switch to
CW
.
2. Set the “METER” switch to
HV
.
3. Set the “LINEAR” switch to
STBY
.
4. While observing the “HV” meter, switch the amplifier
ON
.
Confirm Step-Start Operation.
Confirm HV ramps up initially, plateau, then reaches approximately 2kV after
Step-Start Relay activation.
Confirm that there is no anode current (
IP
reads “0”).
5. Switch the amplifier
OFF
.
6. Set the “MODE” switch to
SSB
.
7. While observing the “HV” meter, switch the amplifier
ON
.
Confirm HV ramps up initially, plateau, then reaches approximately 3kV after
Step-Start Relay activation.
Confirm that there is no anode current (
IP
reads “0”).
8. Switch the amplifier
OFF
.
The operation of the Electronic Bias will be confirmed.
1. Insert the amplifier keying line into the “RL CONT” jack.
2. Ensure the free-end of the keying line is electrically “Open”.
3. While observing the “HV” meter, switch the amplifier
ON
www.KesslerEngineeringLLC.com
Содержание TL-922 Revival (tm)
Страница 7: ...vii List of Tables 3 1 TL 922 Revival tm Modification Kit Contents 5 www KesslerEngineeringLLC com...
Страница 13: ...6 Figure 3 1 TL 922 Revival tm Upgrade Kit Contents www KesslerEngineeringLLC com...
Страница 18: ...11 Figure 3 4 LED Circuit Board Correctly Installed www KesslerEngineeringLLC com...
Страница 30: ...23 Figure 3 19 QSK PCB to QRO Output Connections www KesslerEngineeringLLC com...
Страница 34: ...27 Figure 3 23 Electronic Bias PCB Installed www KesslerEngineeringLLC com...
Страница 46: ...39 3 8 7 Electrical Schematics Figure 3 29 Step Start Schematic Diagram www KesslerEngineeringLLC com...
Страница 47: ...40 Figure 3 30 Step Start PCB www KesslerEngineeringLLC com...
Страница 48: ...41 Figure 3 31 QSK T R Relay Schematic Diagram Figure 3 32 QSK T R Relay PCB www KesslerEngineeringLLC com...
Страница 49: ...42 Figure 3 33 LED Schematic Diagram Figure 3 34 LED PCB www KesslerEngineeringLLC com...
Страница 50: ...43 Figure 3 35 Electronic Bias Schematic Diagram www KesslerEngineeringLLC com...
Страница 51: ...44 Figure 3 36 Electronic Bias PCB www KesslerEngineeringLLC com...
Страница 54: ...47 User Notes www KesslerEngineeringLLC com...
Страница 55: ...48 5 1 User Notes Continued www KesslerEngineeringLLC com...
Страница 56: ...49 5 2 User Notes Continued www KesslerEngineeringLLC com...
Страница 57: ...50 5 3 User Notes Continued www KesslerEngineeringLLC com...