29
Figure 3.24: Amplifier
IG
connection
3.8.5
Filament Transformer Electrical Connections
The connections to the filament transformer will be completed next. When finished making
the electrical connections to the filament transformer, the results should appear as shown in
Figure 3.23.
The
Filament Transformer
includes an isolated 8V secondary winding to provide meter
illumination current and an isolated 80V secondary winding to provide current necessary to
operate the T/R relay.
Note:
While reference is made to the labels printed on the outer layer of the transformer,
often these labels are partially obscured by the warning label. Please refer to the orientation
of the connecting wires shown in Figure 3.23 as a guide.
CT Electrical Connection
•
Solder the
CT
wire lead to the filament transformer
CT
terminal. The
CT
terminal
is the upper left terminal as shown in Figure 3.23.
80V Winding Electrical Connections
The filament transformer 80V secondary winding feeds a full-wave bridge rectifier DC power
supply used to power the QSK T/R relays. The label for the 80V winding may be partially
obscured by the transformer warning label. However, the 80V windings are the two terminals
shown on the right side of the transformer just below the
E
(Ground) terminal (Figure 3.23).
•
Solder the first
80V
wire to the 80V terminal labeled “0.25A” on filament transformer.
•
Solder the second
80V
wire to the 80V terminal labeled “80V” on filament transformer.
www.KesslerEngineeringLLC.com
Содержание TL-922 Revival (tm)
Страница 7: ...vii List of Tables 3 1 TL 922 Revival tm Modification Kit Contents 5 www KesslerEngineeringLLC com...
Страница 13: ...6 Figure 3 1 TL 922 Revival tm Upgrade Kit Contents www KesslerEngineeringLLC com...
Страница 18: ...11 Figure 3 4 LED Circuit Board Correctly Installed www KesslerEngineeringLLC com...
Страница 30: ...23 Figure 3 19 QSK PCB to QRO Output Connections www KesslerEngineeringLLC com...
Страница 34: ...27 Figure 3 23 Electronic Bias PCB Installed www KesslerEngineeringLLC com...
Страница 46: ...39 3 8 7 Electrical Schematics Figure 3 29 Step Start Schematic Diagram www KesslerEngineeringLLC com...
Страница 47: ...40 Figure 3 30 Step Start PCB www KesslerEngineeringLLC com...
Страница 48: ...41 Figure 3 31 QSK T R Relay Schematic Diagram Figure 3 32 QSK T R Relay PCB www KesslerEngineeringLLC com...
Страница 49: ...42 Figure 3 33 LED Schematic Diagram Figure 3 34 LED PCB www KesslerEngineeringLLC com...
Страница 50: ...43 Figure 3 35 Electronic Bias Schematic Diagram www KesslerEngineeringLLC com...
Страница 51: ...44 Figure 3 36 Electronic Bias PCB www KesslerEngineeringLLC com...
Страница 54: ...47 User Notes www KesslerEngineeringLLC com...
Страница 55: ...48 5 1 User Notes Continued www KesslerEngineeringLLC com...
Страница 56: ...49 5 2 User Notes Continued www KesslerEngineeringLLC com...
Страница 57: ...50 5 3 User Notes Continued www KesslerEngineeringLLC com...