4

2.0 Conversion Guide

Often times KEP is asked to give the cable pin out for SMIC cables that have converter boxes in the middle. It
becomes impractical for the user to make the cable electronics but some insist on trying. Usually a
manufacturers programming cable to connect a PC RS232 port to the Controller is the same configuration as
our SMIC cable. The SMIC cable is usually less expensive than the manufacturers in these instances. However
the SMIC cannot be used with a PC. This is because the SMIC draws it power from the ZOID or MMI product
using it. Below is a list of cables with conversion type to use as a reference.

Cable

 PLC Compatibility

 Conversion type

SMICAB500
SMICABAIC

All Allen Bradley SLC500 types with
DH485 port

RS232   

!

   2 wire RS485

SMIC7AB500
SMIC15AB500

 All Allen Bradley SLC500 types with
DH485 port

2 wire RS485  No conversion

SMICABMICRO

Allen Bradley MicroLogix only

RS232  No conversion

SMICABDF1

Allen Bradley SLC5/03, 5/04 with DF1
port

RS232  No conversion

SMICFUJI

All Fuji Flex Series

RS232 

!

 4 wire RS485

SMICGE90

All GE 90 Series SNP Port

RS232 

!

 4 wire RS422

SMIC7GE90
SMIC15GE90

All GE 90 Series SNP-X Port

4 wire RS422  No conversion

SMICIDECM1

IDEC Micro 1 Series only

RS232 

!

 5V TTL Serial

SMICIDECM3

IDEC Micro 3 Series only

RS232 

!

 2 wire RS485

SMICIDECM3C

IDEC Micro 3 Series with RS232 port

RS232  No conversion

SMICK205

Koyo DL230, 240, 250

RS232  No conversion

SMICK305

Koyo 340, Siemens 335, 337

RS232  No conversion

SMICK405

Koyo 440, Siemens 425, 435

RS232  No conversion

SMICKEY

All Keyence KV series

RS232  No conversion

SMICMOD

Controllers with DB9 MODBUS RTU ports

RS232  No conversion

SMICMODMICRO

Modicon Micro 984

RS232  No conversion

300_A1S

Mitsubishi A Series

RS232 

!

 4 wire RS422

500_AnS

Mitsubishi A Series

RS232 

!

 4 wire RS422

SMICMITFX

Mitsubishi FX Series

RS232 

!

 4 wire RS485

SMIC7MITFX
SMIC15MITFX

Mitsubishi FX Series

RS232 

!

 4 wire RS485

SMICMITFXO

Mitsubishi FXo and FXn only

RS232 

!

 4 wire RS485

SMIC15MITFXO

Mitsubishi FXo and FXn only

RS232 

!

 4 wire RS485

SMICOMCH9

Omron CH Series

RS232  No conversion

SMICOMCK25

Omron C series (Host Link Modules)

RS232  No conversion

SMICOMCQM

Omron CQM1 Series

RS232  No conversion

SMICSIS5

Siemens S5 Series

RS232 

!

 Opto-isolated current loop serial

SMIC7S IS7

2 wire RS485  No conversion

SMICSIS7

Siemens S7 200 Series only

RS232 

!

 2 wire RS485

SMICTSBEX

Toshiba EX and M Series, program port
only

RS232 

!

 Current loop serial

SMICTSB485

Toshiba EX and M Series, Link port only

RS232 

!

 4 wire RS485

SMICTSBT1

Toshiba T Series T1 only

RS232  No conversion

SMICTSBT2

Toshiba T Series T2, T3

RS232  No conversion

 SMICTSX07

Telemecanique TSX 07 (nano) and 37
Series

RS232 

!

 2 wire RS485

 SMICTSX17

Telemecanique TSX 17 Series

RS232 

!

 2 wire RS485

 SMICTSX47

Telemecanique TSX 47-40, 47-20

RS232 

!

 Opto-isolated current loop serial

Содержание SMIC

Страница 1: ...0 SMIC Smart Cable Installation and Connection Guide Kessler Ellis Products 10 Industrial Way East Eatontown NJ 07724 Phone 732 935 1320 Fax 732 935 9344 www kep com 99719REV21JAN02 5 00 ...

Страница 2: ...ibed herein which are not present in all hardware Kessler Ellis Products assumes no obligation of notice to holders of this document with respect to changes subsequently made Information in this document is subject to change without notice and does not represent a commitment on the part of Kessler Ellis Products Contents 1 0 Connection guide 2 1 1 Installation Guidelines 2 1 2 SMIC port pinout 3 2...

Страница 3: ...es vapors or dusts Electrical Environment The circuitry is designed to resist the effects of electrical noise This does not guarantee noise immunity in severe cases Be sure to use proper wire routing and grounding to insure proper operation Note The SMIC cables with signal conversion electronics should only be extended at the PLC end of the cable Caution Restrict cable length to less than 500 150m...

Страница 4: ...Pin assignment of the 9 pole SUB D Male Connector Pin Symbol Function 1 Not used 2 TxD Transmitted Data RS232 signal levels 3 RxD Received Data RS232 signal levels 4 Not used 5 GND Signal Ground 6 Not used 7 CTS Clear to send input RS232 signal levels 8 RTS Ready to send output RS232 signal levels 9 RSV Grounding this pin signals the KEP device to begin establishing communications with the control...

Страница 5: ... IDEC Micro 3 Series with RS232 port RS232 No conversion SMICK205 Koyo DL230 240 250 RS232 No conversion SMICK305 Koyo 340 Siemens 335 337 RS232 No conversion SMICK405 Koyo 440 Siemens 425 435 RS232 No conversion SMICKEY All Keyence KV series RS232 No conversion SMICMOD Controllers with DB9 MODBUS RTU ports RS232 No conversion SMICMODMICRO Modicon Micro 984 RS232 No conversion 300_A1S Mitsubishi A...

Страница 6: ...s 335 337 X X SMICK405 Koyo 440 Siemens 425 435 X X X SMICKEY All Keyence KV series X X SMICMOD All PLC s and controllers with DB9 MODBUS RTU ports X X X X SMICMODMICRO Modicon Micro 984 X X X X 300_A1S Mitsubishi A Series X 500_AnS Mitsubishi A Series X SMICMITFX Mitsubishi FX Series X X SMIC7MITFX Mitsubishi FX Series X SMIC15MITFX Mitsubishi FX Series X SMICMITFXO Mitsubishi FXo only X X SMIC15...

Страница 7: ...sting operating and maintenance personnel in the efficient use of the instrument described herein Publication of this information does not convey any rights to use or reproduce or to use it for any purpose other than in connection with the installation operation and maintenance of the equipment described herein Copyright 2000 by Kessler Ellis Products We hope you will be pleased with our product I...

Отзывы: