8. Control of the septic system
8.3.3 Maintenance deadline
Input of the next maintenance deadline by the main-
tenance partner.
8.4.1 Parameters
Change of parameters stored at the factory.
Note: Every change is immediately accepted when
the OK key is pressed. In addition, on quitting this
menu it is possible to save these values in the para-
meter memory (see point 8.4.2) under a separate
name.
8.4.2 Parameter memory
Loading of the values accepted on initialisation and
of the values added under a new name (see 8.4.1).
8.4.3 Date / time
Setting the current date and time.
8.4.4 Floater
Switching the two floaters on and off (second floater
is an optional accessory). The status is displayed in
the system information menu.
8.4.5 Pressure sensor
Activation / deactivation of the pressure sensor. De-
activation deactivates the high water and low water
module and the pressure monitoring system.
8.4.6 High water module
Switching on and off the high water alarm. The height
for the alarm signal preset at the factory is 150 cm.
Parameter
Parameterspeicher
Datum / Uhrzeit
Schwimmer
Drucksensor
Stromüberwachung
HW Modul
UW Modul
Drucküberwachung
Kommunikation
Klassen
Nenngrößen
Sprache
Reset
Informationen
Wartung
Einstellungen
Systeminfo
8.4 Setting menu
8.4.7 Low water module
Switching on and off the low water alarm. The height for the alarm signal preset at the
factory is 80 cm.
8.4.8 Pressure monitoring
Continuous pressure measurement (monitoring) of the INNO-CLEAN® system. The
preset values should not be changed. The pressure monitoring system is deactivated
by deactivating the pressure sensor (see 8.4.5)
8.4.9 Communication
Input / change of the station name, the device number, the modem type, the PINS and
the number of the mobile phone to which possible malfunctions can be sent via SMS
(for a detailed description see separate operating instructions).
8.4.10 Classes
Display / change of purification class.
8.4.11 Nominal sizes
Display / change of nominal size.
8.4.12 Language
Display / change of language
8.4.13 Reset
Resetting the control unit to the factory setting (operating hours are not reset).
8.4.14 Current monitoring
Continuous current measurement (monitoring) of the
INNO-CLEAN
®
system. The pre-
set values should not be changed. Current monitoring is deactivated by setting the bot-
tom current limit to 0.0 A.
Information
Maintenance
Positions
Float
Date/time
Pressure sensor
Classes
Parameter
Nominal size
Parameter storage
Pressure monitor
Communication
Language
Reset
Electricity control
Inno-Clean_2. Generation_3-sprachig_132Seiten:010-341 Stand 05/07 26.11.2009 12:44 Uhr Seite 118
Содержание INNO-CLEAN
Страница 128: ...Spare Parts Inno Clean_2 Generation_3 sprachig_132Seiten 010 341 Stand 05 07 26 11 2009 12 44 Uhr Seite 128 ...
Страница 130: ... Notice 130 Inno Clean_2 Generation_3 sprachig_132Seiten 010 341 Stand 05 07 26 11 2009 12 44 Uhr Seite 130 ...
Страница 131: ... Notice 131 Inno Clean_2 Generation_3 sprachig_132Seiten 010 341 Stand 05 07 26 11 2009 12 44 Uhr Seite 131 ...