34/120
2016/02
TECHNICAL DATA
5.
Technical data
Current
4.9 A /cos
ɸ = 1
Operating mode pump
S3 - 30% at 35°C
Delivery rate at 0.3 bar backwater pressure
Q = 2.8 l/s
Mains voltage (primary)
230 V AC 50 Hz (plug)
Standby power
approx. 2.5 W
Power
1200 W max.
Potential-free contact (accessory)
42 V DC / 0.5A
Application temperature control unit
0°C to + 50°C
Protective rating
IP 54 (control unit),
IP 68, 0.3 bar (pump, probe) 24 h
Protective class
I
Protective rating (complete system without control unit)
IP 68 with max. 3 mWS and max. 24 h
Connection type
Safety plug
Cable length
1.4m
Required fuse protection
C 16 A 1-pole
battery, 9V type MN, Duracell, order no. 197-081 *2)
2 x
Alternatively, the following can be used (9V, ANSI 1604): Energizer Alcaline 522, Ultralife U9VLBP
5.1.
Shortening or lengthening the pump/probe connection cable
Extensions to be ordered (length 10m)
• Art. # 80889 Probe
• Art. # 80890 Motor
• Art. # 80891 Pump
The maximum cable length of 30 m must not
per hour.
If a connection cable is shortened, the wires must
be placed as shown in Fig. [30].
[16]
2.
3.
1.
Содержание Control Unit Ecolift 230V
Страница 19: ...19 120 2016 02 KONFORMIT TSERKL RUNG 7 Konformit tserkl rung...
Страница 39: ...39 120 2016 02 DECLARATION OF CONFORMITY 7 Declaration of conformity...
Страница 59: ...59 120 2016 02 D CLARATION DE CONFORMIT...
Страница 79: ...79 120 2016 02 DICHIARAZIONE DI CONFORMIT 7 Dichiarazione di conformit...
Страница 99: ...99 120 2016 02 CONFORMITEITSVERKLARING 7 Conformiteitsverklaring...
Страница 119: ...119 120 2016 02 DEKLARACJA ZGODNO CI 7 Deklaracja zgodno ci...