Technical data
41 / 148
2018/02
6
Technical data
Comfort Plus SD 400V
Maximum power at switching output [kW]
(with cos Phi = 1)
9.7
15.9
Nominal current range* [A]
(in operation, 2 each)
9-14
17-23
Weight [kg]
12.1
Dimensions (LxWxD), [mm]
558x378x180
Operating voltage
400 V AC / 50Hz
Standby power
7W
Potential-free contact
max. 42 V DC / 0.5 A
Battery
2 x 9V 6LR614
Working temperature
0 - 40°C
Protective rating
IP 54
Protection class
I
Connection type
Direct connection
Mono fusing required
3xC16A
3xC32A (3xK32A**)
Duo fusing required
3xC32A
3xC63A
RCD
30 mA