18
2. Technical data
2.1 Dimensioned drawing
Sludge trap
(l)
17
130
360
LW
(mm)
400
800
1000
Qmax.
(l/s)
1.5
1.5
1.5
DN
100
100
100
L
(mm)
582
1091
1425
B
(mm)
520
1012
1300
D
min
max
231
324
518
942
570
995
Excess depth
(mm)
50
50
70
NS
1.5
1.5
1.5
h2
(mm)
389
508
630
h1
(mm)
342
461
583
Oil storage
(l)
17.6
70.5
110
Weight
(kg)
12
74
110
Separator capacity
(l)
43
230
580
Art. no.
99601.002B
99601.016B/D
99601.041B/D
Note and follow the chapter „Safety instructions“!
3.1 Transport
The tanks must be transported in such a way that they are not
subjected to excess loading and a change in position during
transport is prevented. Transport restraints must be used to pre-
vent damage to the tanks (e.g. use of textile straps, hemp ropes).
Use of wire ropes or chains is not permitted.
3.2 Storage
If it is necessary to store the tanks prior to installation, this may
only be done temporarily and on level ground that has been
cleared of any sharp-edged objects. In case of outdoor storage,
the tanks must be protected against damage, exposure to storms
and dirt.
3. Packaging, transport and storage