Kerotest Manufacturing
–
SHANNON & PAF III OPERATORS MANUAL - REV 3
Page 27 of 60
If no errors were encountered, the
Kerotest Electrofusion Processor
will display a screen similar to the
following:
VERIFY SETUP
INNO 2
” CO
UPL
40.0V 60 sec
PRESS START
The VERIFY SETUP screen allows the operator a final opportunity to verify that the fusion parameters
displayed are correct and match the parameters specified by the fitting manufacturer before starting the
fusion.
ALWAYS pay close attention and verify the information on this screen is correct before pressing
START.
IT IS THE RESPONSIBILITY OF THE OPERATOR TO VERIFY THAT ALL THE INFORMATION DISPLAYED IS
CORRECT PER THE FITTI
NG MANUFACTURER’S RECOMMENDATIONS FOR FUSING
THE ATTACHED FITTING
UNDER THE CURRENT AMBIENT CONDITIONS.
The processor will BEEP once per second and the text “PRESS START” on the bottom line of the display will
flash on and off.
Once you have verified that all measurements and parameters are correct, press the
START button
to begin
the fusion.
If errors were encountered while decoding the barcode number that was manually entered, you will receive
an Error Message and will be forced to check the number and reenter it.
FAILURE TO VERIFY THAT THE FUSION INFORMATION IS CORRECT BEFORE STARTING A FUSION COULD
RESULT IN SIGNIFICANT DAMAGE TO PROPERTY, PERSONAL INJURY, AND/OR DEATH.
NOTE:
If Calculated Resistance is enabled and the operator receives a Warning Code 55, refer to the appropriate
section on page 42 for instructions that detail how to proceed.
See page 29 for instructions on monitoring the progress of a fusion.
Manual Data Entry
**The Barcode Fusion Method is always preferred and should be used whenever possible
.
Manual Mode
should only be used when the barcode is malfunctioning or unavailable
.
FOR EXPERT OPERATORS
ONLY.
Manual Data Entry Fusions require additional care and attentiveness on the part of the operator to
ensure that the appropriate fusion parameters are entered. For this reason, Manual Fusions should ONLY be
performed by a fully trained operator using specifications provided by the fitting manufacturer.
NOTE:
The
Kerotest Electrofusion Processor
provides outputs for a complete fusion based on parameters
manually entered by the operator. Remember to enter all parameters
EXACTLY
as specified by the fitting
manufacturer.
Содержание Shannon Portafuse III
Страница 1: ......
Страница 2: ......
Страница 59: ...Kerotest Manufacturing SHANNON PAF III OPERATORS MANUAL REV 3 Page 57 of 60 Page Intentionally Left Blank ...
Страница 60: ...Kerotest Manufacturing SHANNON PAF III OPERATORS MANUAL REV 3 Page 58 of 60 Page Intentionally Left Blank ...
Страница 61: ...Kerotest Manufacturing SHANNON PAF III OPERATORS MANUAL REV 3 Page 59 of 60 Page Intentionally Left Blank ...
Страница 62: ...Kerotest Manufacturing SHANNON PAF III OPERATORS MANUAL REV 3 Page 60 of 60 Page Intentionally Left Blank ...
Страница 63: ......