PRIMARY REPACKING PROCEDURE – EARLY DESIGN BEFORE (1988)
CONDITION 1 – VALVE UNDER PRESSURE
10.
Place upper thrust washer (6) on stem (10) if removed. Position gasket (5) and gland
(4) on cover. Insert cap screws (3) fully and tighten to torque shown in Table I. Place
operating square (2) on stem and then secure with nut (1).