KERN VHT Скачать руководство пользователя страница 5

2  Declaration of conformity 

KERN & Sohn GmbH 

D-72322 Balingen-Frommern 
Postbox 4052 
email: [email protected] 

Phone: 0049-[0]7433- 9933-0 
Fax: 0049-[0]7433-9933-149 
Internet: www.kern-sohn.de 

Declaration of conformity 

EC-Konformitätserklärung 

 

  EC-Declaration 

of 

-Conformity 

EC-

 

Déclaration de conformité 

 

 

 

EC-Declaración de Conformidad 

EC-Dichiarazione di conformità 

 

 

 

EC-Conformiteitverklaring 

EC- Declaração de conformidade 

 

 

 

EC- Prohlášení o shode 

EC-Deklaracja zgodno

ś

ci 

 

  EC-

Заявление

 

о

 

соответствии

 

 

Konformitäts-
erklärung 

Wir erklären hiermit, dass das Produkt, auf das sich diese Erklärung bezieht, 
mit den nachstehenden Normen übereinstimmt. 

GB 

Declaration of 
conformity 

We hereby declare that the product to which this declaration refers conforms 
to the following standards.  

CZ 

Prohlášení o 
shode 

Tímto prohlašujeme, že výrobek, kterého se toto prohlášení týká, je v souladu 
s níže uvedenými normami. 

Declaración de 
conformidad 

Manifestamos en la presente que el producto al que se refiere esta 
declaración está de acuerdo con las normas siguientes 

Déclaration de 
conformité 

Nous déclarons avec cela responsabilité que le produit, auquel se rapporte la 
présente déclaration, est conforme aux normes citées ci-après. 

Dichiarazione di 
conformitá 

Dichiariamo con ciò che il prodotto al quale la presente dichiarazione si 
riferisce è conforme alle norme di seguito citate. 

NL 

Conformiteit-
verklaring 

Wij verklaren hiermede dat het product, waarop deze verklaring betrekking 
heeft, met de hierna vermelde normen overeenstemt. 

Declaração de 
conformidade 

Declaramos por meio da presente que o produto no qual se refere esta 
declaração, corresponde às normas seguintes. 

PL 

Deklaracja 
zgodno

ś

ci 

Niniejszym o

ś

wiadczamy, 

ż

e produkt, którego niniejsze o

ś

wiadczenie 

dotyczy, jest zgodny z poni

ż

szymi normami. 

RUS 

Заявление

 

о

 

соответствии

 

Мы

 

заявляем

что

 

продукт

к

 

которому

 

относится

 

данная

 

декларация

соответствует

 

перечисленным

 

ниже

 

нормам

 

Electronic Scale: 

KERN VHB, VHE, VHS, VHT  

 

 
 

Mark applied 

EU Directive  Standards 

2004/108/EC 
 

EN 55022 :1994 /A1 : 1995/A2 : 1997 Class A 
EN 50082-1 : 1992 
EN 61000-3-2 : 1995/A1: 1998 / A2:1998 
EN 61000-3-3 : 1995 

 

2006/95/EC 

EN 60950 : 1992/A1: 1993 / A3: 1995 / A4: 1997 / A11: 1997 

 

Date: 24.09.2008 

Signature:

 

 

 

Gottl. KERN & Sohn GmbH 

 

 

 

Management 

 

 

 

Gottl. KERN & Sohn GmbH, Ziegelei 1, D-72336 Balingen, Tel. +49-[0]7433/9933-0,Fax +49-[0]7433/9933-149

 

 

 

VHT-BA-e-0910 

5

Содержание VHT

Страница 1: ...bH Ziegelei 1 D 72336 Balingen email info kern sohn com Phone 49 0 7433 9933 0 Fax 49 0 7433 9933 149 Internet www kern sohn com Operating Manual Pallet truck scales KERN VHT Version 1 0 01 2009 GB VH...

Страница 2: ...4 1 Pay attention to the instructions in the Operation Manual 7 4 2 Personnel training 7 5 TRANSPORTATION STORAGE 7 5 1 Testing upon acceptance 7 5 2 Packaging 7 6 UNPACKING SETUP AND COMMISSIONING 8...

Страница 3: ...y placing the parts 16 7 7 2 Piece counting by means of input piece weight 17 7 8 Adding 18 7 9 Weighing units switch over 18 7 10 PRINTING 19 7 11 PAPER CHANGE 21 7 12 Change of date and time on the...

Страница 4: ...00 kg 2000 kg Reproducibility 200 g 500 g 1000 g Linearity 200 g 500 g 1000 g Warm up time 10 min Allowable ambient temperature 10 C 40 C Humidity of air max 95 Weighing Units kg Rechargeable battery...

Страница 5: ...s normas siguientes F D claration de conformit Nous d clarons avec cela responsabilit que le produit auquel se rapporte la pr sente d claration est conforme aux normes cit es ci apr s I Dichiarazione...

Страница 6: ...This may damage the measuring system Impacts and overloading exceeding the stated maximum load max of the balance minus a possibly existing tare load must be strictly avoided Balance may be damage by...

Страница 7: ...rd fast and at moderate cost 4 Basic safety instructions for scales 4 1 Pay attention to the instructions in the Operation Manual Carefully read this operation manual before setup and commissioning ev...

Страница 8: ...load centre is between the forks The forks are easily bent and twisted when the load is off centre This may result in diminished accuracy In verifiable models off centre loads or slants affecting acc...

Страница 9: ...35 hours without interruption system without printer If the loading status of the rechargeable battery is too low the display shows LO BA If the battery is completely exhausted the lifting truck switc...

Страница 10: ...rview of display PRE PRINT TOTAL C ZERO NET Max 200 kg d 0 2 kg Max 500 kg d 0 5 kg Max 2000 kg d 1 kg ON UNIT OFF pcs kg lb The seven displays provide the following information The weighing system in...

Страница 11: ...d piece quantity Display of adjustment value Taring carried out dosing process Confirmation dosing carried out Display of parameter number Dosing process cancelled Display of hours setting Display of...

Страница 12: ...otal Entering numeric values Increases the numeric value of flashing digit by 1 Calculation of the piece weight Input of the piece weight Entering numeric values Confirms the flashing value ON UNIT OF...

Страница 13: ...provides automatic zero adjustment This means that small deviations from the zero point are corrected automatically If the display unit does not correct the zero point automatically you will have to c...

Страница 14: ...RE button for approx 3 seconds Press the numeric up PRINT TOTAL or down PRE button until the flashing number has reached the desired value To move to the next segment press the button Repeat this acti...

Страница 15: ...ata Press button for approx 3 seconds On the display device appears the code entered as last The right hand cipher flashes Press anew the button when the displayed code shall be maintained The code is...

Страница 16: ...indicator will show ERR05 Press any button to return to the piece counting mode and increase the quantity to be calculated 7 7 1 Piece counting by placing the parts Press the button In the display app...

Страница 17: ...layed piece weight The weighed piece quantity is displayed or Change the piece weight using PRINT TOTAL or PRE button The new piece weight will be displayed Press the button in order to use the new pi...

Страница 18: ...ays for 3 seconds the consecutive numbers number of weighings and the total value of the weighings in the memory As long as the total value is displayed press the PRINT TOTAL button for approx 3 secon...

Страница 19: ...inted out Date and time are only printed out if this option has been installed Press button A printout will be made The current weight is added to the addition memory On the printout a gross weight wi...

Страница 20: ...4 5 kg T 34 5 kg N 1200 0 kg No 1 10 11 08 17 45 Example piece counting printout without code B G 1234 5 kg T 34 5 kg N 1200 0 kg PcWt 1 234 kg Qty 12345 PCs No 1 10 11 08 17 45 Example piece counting...

Страница 21: ...ply too much force in order to avoid damage Insert the paper roll the loose side has to point forwards over the printer Hold fast the loose side of the paper roll when the printer is being closed so t...

Страница 22: ...Remove the old paper roll and insert the new one as shown above so that the roll is unspooled in the correct sense Unspool the roll a little and close the cover Thereby hold fast the paper end at the...

Страница 23: ...cipher and set the desired value also by means of PRINT TOTAL or PRE Use to confirm the desired hours setting In the display appears m_00 or the last minutes setting Set the desired value as describe...

Страница 24: ...aged by overloading General rules As the steering wheels are mounted at the front it is better to pull rather than push the manual pallet truck If the lifting device is not used the manual lever shoul...

Страница 25: ...atically to correction and input Err07 Load cell signal too low Automatically to correction and input Err08 Calibration outside the range negative Automatic Err09 Calibration outside the range signal...

Страница 26: ...Sites with vibration Loading fork is in contact with foreign matter Electromagnetic fields static charging choose different location switch off interfering device if possible The weighing value is ob...