PLJ-N-BA-e-1333
65
15.5 Communication protocol / remote control commands
Instruction:
Meaning of Instruction:
Z
Set weight display at zero
T
Taring
S
Send weight value immediately
SI
Send stable weight value
SU
Send stable weighing value in current weighing value
SUI
Send weighing value immediately in current weighing unit
C1
Turn on continuous transmission in standard weighing unit
C0
Turn off continuous transmission in standard weighing unit
CU1
Turn on continuous transmission in current weighing unit
CU0
Turn off continuous transmission in current weighing unit
Complete each instruction with
CR LF
.
15.5.1 Manual output
The user may start output manually by pressing the
-key (For settings see
chapter 16.4.5, function “
P4.5 PStb
”, locked for verifiable devices).
Data record format:
1
2 3
4 - 12
13
14 - 16
17
18
S
tab
ili
ty
i
n
di
c
ato
r
B
lan
k
S
ign
s
W
ei
gh
t
B
lan
k
Uni
t
CR
LF