background image

       Operating Instructions  Hanging Balance

 

GB 

 

 

1 Technical 

Data 

KERN 

MH5K5 

MH10K10 

Readout 5 

10 

Weighing range 

5 kg 

10 kg 

Fundamental information (general) 

2.1 Intended 

use 

The balance you have acquired serves to determine the 
weighing value of the material to be weighed. It is intended to 
be used as a “non-automatic“ balance, i.e. the material to be 
weighed is manually and carefully attached at the balance. The 
weighing value can be read off after a stable weighing value 
has been obtained.  

2.2 Inappropriate 

use 

Do not use the balance for dynamic weighing. In the event that 
small quantities are removed or added to the material to be 
weighed, incorrect weighing results can be displayed due to the 
“stability compensation“ in the balance. (Example: Slow flow of 
liquids from a container suspended from the balance).  
Do not suspend a permanent load from the balance This can 
damage the measuring equipment (Risk of fracture).  Be sure 
to avoid impact shock and overloading the balance in excess of 
the prescribed maximum load rating (max.), minus any 
possible tare weight that is already present.  This could cause 
damage to the balance(danger of fracture).  

Important:  

Always make sure that there are no living beings or 
materials below the load that could be injured or 
damaged!

 

The balance is not suitable for weighing living beings. 
Do not use as baby scales!  

The balance does not comply with the medical 
product law (MPG).

   

Never operate the balance in hazardous locations. The series 
design is not explosion-proof.  Structural alterations may not be 
made to the balance. This can lead to incorrect weighing 
results, faults concerning safety regulations as well as to 
destruction of the balance.  The balance may only be used in 
compliance with the described guidelines. Varying areas of 
application/planned use must be approved by KERN in writing.   

2.3 Guarantee 
The guarantee is not valid following  

non-observation of our guidelines in the  operating    

instructions  

- use outside the described applications  
- alteration to or opening of the device  
- mechanical damage and damage caused by media, liquids  
- natural wear and tear  
- inappropriate erection or electric installation  
- overloading of the measuring equipment

  

2.4 

Monitoring the test substances 

The metrology features of the balance and any possible 
available adjusting weight must be checked at regular  
intervals within the scope of quality assurance. For this purpose, 
the answerable user must define a suitable interval as well as the 
nature and scope of this check. Information is available on 
KERN’s home page (

www.kern-sohn.com

) with regard to the 

monitoring of balance test substances and the test weights 
required for this.  Test weights and balances can be adjusted 
quickly and at a reasonable price in KERN’s accredited DKD 
calibration laboratory (return to national normal). 

Fundamental safety information 

3.1  Observe the information in the operating instructions 
Please read the operating instructions carefully before erecting 
and commissioning, even if you already have experience with 
KERN balances.   

3.2 Staff 

training 

The device may only be operated and looked after by trained 
members of staff.  

Transport and storage 

4.1 Acceptance 

check 

Please check the packaging immediately upon delivery and the 
device during unpacking for any visible signs of external 
damage.  

4.2 Packaging 
Please retain all parts of the original packaging in case it 
should be necessary to return items at any time.  
Only the original packaging should be used for return 
consignments.  Before despatch, disconnect all attached 
cables and loose/movable parts. Apply any intended transport 
security devices. Secure all parts, e.g. glass windshield, 
weighing plate, power unit etc., to prevent slipping and 
damage. 

Unpacking, installation and commissioning 

5.1 

Place of installation, place of use 

The balance is constructed in such a way that reliable weighing 
results can be achieved under normal application conditions.  
By selecting the correct application location

  f

or  your balance, 

you will be able to work quickly and precisely.  

Therefore please observe the following at the

 

application 

location

• 

Avoid extreme heat as well as temperature fluctuation 
caused by installing next to a radiator or in the direct 
sunlight;  

• 

Protect the balance against direct draughts due to open 
windows and doors;  

• 

Avoid jarring during weighing;  

• 

Protect the balance against high humidity, vapours and 
dust;  

• 

Do not expose the device to extreme dampness for longer 
periods of time. Inadmissible bedewing (condensation of air 
moisture on the device) can occur if a cold device is taken 
into a significantly warmer environment.  In this case, 
please acclimatise the device for approx. 2 hours at room 
temperature after it has been disconnected from the 
batterys.  

• 

Avoid static charging of the material to be weighed, 
weighing container and windshield.   

 
Major display deviations (incorrect weighing results) are 
possible if electromagnetic fields occur as well as due to static 

MH-BA-defsin-0312 

4

 

Отзывы: