EN – Installation instructions
The radiator may only be installed by a specialist.
Safety instructions
W
Read these instructions thoroughly prior to
installation/commissioning.
W
After installation,
pass the instructions on
to the end user
.
WARNING
Risk of injury!
W
Take the weight of the radiator into account
(see manufacturer's data).
W
At 25 kg and above work with lifting equip-
ment or several persons.
Conditions of use
W
Observe operating conditions for water heat-
ing installations according to local regulations.
W
Maintain water quality according to local
regulations.
W
Observe usage limits in humid spaces
according to local regulations.
W
Use radiator only in closed heating systems.
W
Store and transport radiator only in the protec-
tive packaging.
W
Observe minimum clearances between radiator
and surrounding objects for air circulation.
Complaint
W
Please contact the supplier.
Disposal
W
Packaging and any parts that are not needed
should be recycled or disposed of properly. Ob-
serve local regulations.
Technical features
•
Operating pressure: max. 10 bar
•
Test pressure: 1.3 x operating pressure
•
Flow temperature: hot water up to 110°C
(230°F)
Directions for installation
Protect radiator from damage
W
When installing, only remove protective pa-
ckaging at the fastening and connection
points.
W
Only remove protective packaging completely
during final cleaning or prior to commissioning.
Fixing
W
Note the number and position of mounting
points (see Fig. A).
W
Install mounting material according to separa-
te installation instructions.
Note:
The two securing screws at the lower
brackets are not required for the short wall brack-
et (two-row installation).
Connection
W
Unscrew painted blind plugs at the designated
connection points.
W
Connect radiator with commercially available
fittings upstream.
For connection of the radiator with an inflow and
return at the bottom:
W
Tightly cap open connections with vent plugs
(top) and blind plugs.
For connection of the radiator with an inflow and
return at the top:
W
Tightly cap open connections with blind plugs.
W
Ensure that the radiator is vented via the pi-
ping system,.
WARNING
Permissible type of installation when connec-
ting the radiator with flow and return at the
top with a short wall bracket, the half is in two
rows.
Removed blind plugs may only be used on Kermi
steel panel radiators.
Commissioning
W
Fill and vent the radiator.
Risk of scalding!
W
Check radiator and connections for leaks.